VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
VQZ Note) Rubber seal only 3-position closed center 2(B) (A)4 Coil voltage SQ 3 24 VDC 12 VDC 5 Note) 6 (R1)5 1 (P) 3(R2) VFS Note) Only 24 VDC is available with the S kit. 3-position exhaust center D Slide locking type (Manual) VFR 2(B) (A)4 Light/surge voltage suppressor 4 VQ7 Yes None (Non-polar) Nil E Note1, 2) (R1)5 1 (P) 3(R2) Note 1) Not applicable to the S kit.
0.01 to 0.1 VDC 3.7 to 4.3 mA DC 0.02 to 0.2 mA DC 1 to 5 VDC 0 to 10 VDC 4 to 20 mA DC 0 to 20 mA DC 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 Note 1) Enter symbols above in VY1D00-.
Note) Rubber seal only 3-position closed center 2(B) (A)4 Coil voltage 3 24 VDC 12 VDC 5 Note) 6 (R1)5 1 (P) 3(R2) Note) Only 24 VDC is available with the S kit. 3-position exhaust center D: Slide locking type (Manual) 2(B) (A)4 Light/surge voltage suppressor 4 Yes None (Non-polar) Nil E Note1, 2) (R1)5 1 (P) 3(R2) Note 1) Not applicable to the S kit.
Mounting with bracket Fix the bracket to the product with the set screws M3 x 5 L (2 pcs.) or M4 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm for the M3 set screws and 1.4 to 1.6 Nm for the M4 set screws.
Power supply voltage for control and input is below 19 VDC. Red PWR LED is ON. (Diagnosis is activated) Supply 24 VDC 10% for control and input power source. 8 Red PWR(V) LED is ON. (Diagnosis is activated) Power supply voltage for output is below 19 VDC. Supply 24 VDC +10/-5% for output power source.
(ZSM1-115) to 100 VDC to 100 VAC 24 to 125 VDC 100 to 250 VAC 24 to 220 VDC 100 to 550 VAC Voltage 100 VAC/DC or less (ZSM1-121) Repeatability 0.05 MPa 0.05 MPa 3% F .S. 3% F.S. 3% F.S. 3% F.S. 10% F.S. 15 kPa or less (ZSM1-115) 0.02 to 0.35 MPa (Without pointer scale) 0.03 to 0.4 MPa (Without pointer scale) Hysteresis (Calibration range of ISG) 0.08 MPa or less 0.01 to 0.2 MPa 7 to 53 kPa
OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC FUNC FUNC U Blue DC () Blue DC () -E PNP (1 output) + Analog voltage output -F PNP (1 output) + Analog current output Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 + + White OUT2 White OUT2 12 to 24 VDC 12 to 24 VDC Load Load FUNC FUNC U Blue DC () Blue DC () The FUNC terminal is connected when using the copy function.
12 VDC 6 VDC 5 VDC 3 VDC With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) DOZ is not available.
Ion generation stars by disconnecting PNP specification: Ion generation is stopped by connecting to 24 VDC .
LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC
Since voltage drops due to the internal circuit in S and Z types, the allowable voltage fluctuation should be within the following range. 24 VDC: 7% to +10% 12 VDC: 4% to +10% XC37 to XC46 Change of rotation range and angle adjusting direction S, W, Y Change of rotation range and angle adjusting direction (Angle adjusting screw is equipped on the left.)
6 12 VDC V 6 VDC S 5 VDC R 3 VDC F G Supply valve/Release valve combination Pilot valve J K Supply valve Nil DC: 1 W (With indicator light: 1.5 W) AC Supply valve and release valve A Supply valve (N.O.)
AV Response time 10 ms 30 ms Fluid Air/Inert gas AU 0 to 50C (With no condensation) Ambient and fluid temperature AF 0.88 MPa Maximum operating pressure Regulating pressure range 0.05 MPa to supply pressure AR Set pressure to 0.88 MPa (VY101) External pilot pressure (Direct operated) 1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC Command signal IR 12 VDC 10%, 24 VDC 10%, 1.8 W
Absolute (Step Motor 24 VDC) The following graphs show the values when the moving force is 100%.
Mount the sensor head using two M3 screws (not supplied with the product). M3 screws M3 screws M3 screws Due to the construction of the sensor, the sensor head housing is shared with GND. Install and supply power with great caution to avoid short-circuit with the +24 V power supply. The detection port is opened to detect static electricity.
Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PF2MC7501/7102 (M3 x 5, 2 pcs.) ZS-42-B Bracket With mounting screws for PF2MC7202 (M3 x 5, 2 pcs.)
, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC Command signal IR 12 VDC 10%, 24 VDC 10%, 1.8 W or less Power supply Electrical entry DIN terminal VEX Applicable cable Cable O.D. 4 to 6.5 When not operating: Zero, When operating: Max. 10 /min (ANR) (Supply pressure 0.88 MPa) Bleed air flow AMR Installation Universal ITV (3) Lubrication Not required Note 1) The weight of the base mounting type
Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.
Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping. The switch can be installed horizontally depending on the installation location. PSE IS Mounting screw M3 x 5L Mounting screw M3 x 5L ISG ZSM The tightening torque for bracket mounting screw should be 0.98 Nm or less.