Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.
n: Stations (maximum 16 stations) Dimensions 16 326 340 437.5 448 15 308.5 322.5 425 435.5 14 291 305 412.5 423 13 273.5 287.5 387.5 398 12 256 270 375 385.5 11 238.5 252.5 350 360.5 10 221 235 337.5 348 9 203.5 217.5 325 335.5 8 186 200 300 310.5 7 168.5 182.5 287.5 298 6 151 165 262.5 273 5 133.5 147.5 250 260.5 4 116 130 237.5 248 3 98.5 112.5 212.5 223 2 81 95 200 210.5 1 63.5 77.5 175
Hz) Single-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz) Single-phase 200 to 230 VAC (50/60 Hz) CE/UL HRS018 1700/1900 (50/60 Hz) HRS024 Single-phase 200 to 230 VAC (50/60 Hz) 2100/2400 (50/60 Hz) Air-cooled refrigeration HRS050 New Scheduled for 2011 4700/5100 (50/60 Hz) Single-phase 200 to 230 VAC (50/60 Hz) UL standards: Applicable to 60 Hz only 1 Thermo-chiller Series HRS Compact Type
Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
Standard Stroke Bore size (mm) Standard stroke (mm) 20 20, 30, 50, 100, 150, 200 25 20, 30, 50, 100, 150, 200 32 25, 50, 100, 150, 200 40 25, 50, 100, 150, 200 50 25, 50, 100, 150, 200 63 25, 50, 100, 150, 200 Manufacture of Intermediate Stroke Intermediate strokes of 1 mm each can be produced by using spacers with standard stroke cylinders.
Hz 200 VAC 50/60 Hz 110 VAC [115 VAC] 50/60 Hz 220 VAC [230 VAC] 50/60 Hz 24 VDC 12 VDC Note 1) Refer to the below table (1) for combinations with light/surge voltage suppressors.
mm/sec Cylinder stroke: 200 mm AQ The set pressure can be either fixed or variable.
Operating range Cylinder model C D 8 8 8 8 Mounting bolt size M3 x 50 L M3 x 60 L M3 x 50 L M3 x 60 L M5 x 75 L M5 x 85 L M5 x 75 L M5 x 85 L M5 x 85 L M5 x 95 L M5 x 75 L M5 x 85 L M6 x 95 L M6 x 130 L M8 x 100 L M8 x 130 L 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20
Direct operation poppet Air, Inert gas 2.0 Al HNBR 20 to 60 10 to 60 (No freezing) Dustproof and jetproof (Equivalent to IP65) Environment with no corrosive or explosive gas 0.2 or less Free 30/150 or less 24/12 VDC, 100/110/200/220 VAC (50/60 Hz) 10% rated voltage B type VCA2: 6.5 W Valve type Fluid Withstand pressure MPa Body material Seal material Ambient temperature C Fluid temperature
300 400 500 600 700 800 6 CJ2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 60 mm 10 16 20 25 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 32 40 50 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 63 80 0 100 200 300 400 500 600 700 800 Average speed [mm/s] * Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the
160 176 110 125 9 9 88 165 M8 37 160 1/8 86.5 30 62 4 142 19 19 190 210 115 135 11 12 96 200 42 194 1/8 95 35 67 4 M10 GL GQ GR I J K L M N O P Note 2) Q R S T U V W Bore size (mm) 20 25 32 40 5.5 4 4 35 60 80 105 50 25 M6 x 1 M5 x 0.8 94 12 26 16 112 53 50 9 7 7 40 70 95 125 60 32 M5 x 0.8 104 12 31 20 132 63 60 M8 x 1.25 9 7 7 40 70 95 125 60 32 1/8 104 12 38 20 132 63 60 M8 x 1.25 11 8
100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different conditions,
VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 30 25 26 25 Refer to page 94.
Description Symbol Description Applicable model Model combination AC20 to 60 AC20 to 60 AC20 to 60 AC20 to 60 AC25 to 60 AC20 AC25 to 60 AC20 to 60 AC20 to 60 1 Note 8) 0.02 to 0.2MPa setting Combination 2 3 6 8 C J Note 9) Metal bowl Symbol Filter Regulator Mist Separator Regulator Air filter Lubricator Lubricator with drain cock Nil A B C D M G A Nylon bowl (including sight dome) M G
50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 200 180 160 140 120 100 80 60 40 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 200 180 160 140 120 100 80 60 40 20 0 Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Vacuum pressure Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] Suction flow rate Suction flow rate
0 100 200 300 400 500 600 700 0 50 100 150 200 250 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 238 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SLOVENIA SMC Slovenia d.o.o.
20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 0 20 40 60 80 100 120 0 20 40 60 80 100 120 Gripping point distance R [mm] Gripping point distance R [mm] Gripping point distance R [mm] Gripping point distance R [mm] 1 2 1 2 MHL2-20DZ MHL2-25DZ MHL2-25D Z MHL2-20D Z 200 200 120 120 160 160 Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6
-D IS10L-40-m02-D IS10L-40-m03-D IS10L-40-m04-D IS10L-60-m04-D IS10L-60-m06-D IS10L-60-m10-D Pressure switch with L-shaped piping adapter*5, *6 IS10L-20-m01-D IS10L-20-m02-D IS10L-50-m04-D IS10L-50-m06-D p. 56 IS10E-40-m02-D IS10E-40-m03-D IS10E-40-m04-D IS10E-40-m06-D IS10E-60-m06-D IS10E-60-m10-D IS10E-60-m12-D IS10E-60-m14-D IS10E-20-m01-D IS10E-20-m02-D IS10E-20-m03-D IS10E-30-m02-D IS10E