SMC Corporation of America
Elite Part Number Search
Search Results "PVQ13-6L-03-A"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, PROPORTIONAL, VALVE, PVQ PROPORTIONAL VALVE, 2H, PVQ NO SIZE RATING, .00000 lb

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. This construction enables low leakage, while de-energized. PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment, as well as, cooling for laser machinery etc.

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. This construction enables low leakage, while de-energized. PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment, as well as, cooling for laser machinery etc.

PVQ series, compact proportional solenoid valve, was designed by SMC with a direct poppet construction. ?This construction?enables low leakage, while de-energized.? PVQ series has been used in applications such as air blow, flow control, hand piece control for dental unit and other respiratory equipment,?as well as, cooling for laser machinery etc.

Style: Pressure Switch w/ T-Spacer, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 03 (3/8), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ T-Spacer, Body Size: 30 (AC30), Thread Type: Rc, Port Size: 03 (3/8), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: 30 (AC30), Thread Type: Rc, Port Size: 03 (3/8), Set Pressure Range: 6 (0.1 to 0.6 MPa), Pressure Unit of the Scale Plate: MPa, Lead Wire Length: L (3m), Mounting Position: Right

Style: Pressure Switch with Piping Adapter, Body Size: 30 (AC30), Thread Type: Rc, Port Size: 03 (3/8), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Style: Pressure Switch with Piping Adapter, Body Size: 40 (AC40), Thread Type: Rc, Port Size: 03 (3/8), Set Pressure Range: 6 (0.1 to 0.6 MPa), Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Body Size: AC30, Thread Type: Rc, Port Size: 3/8, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa, Mounting: Right

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: AC30, Thread Type: Rc, Port Size: 3/8, Set Pressure Range: 0.1 to 0.6 MPa, Pressure Unit of the Scale Plate: MPa, Lead Wire Length: 3m, Mounting Position: Right

Style: Pressure Switch w/ T-Spacer, Body Size: AC40, Thread Type: Rc, Port Size: 3/8, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: Rc, Port Size: 3/8, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, PROPORTIONAL, VALVE, PVQ PROPORTIONAL VALVE, 2H, PVQ NO SIZE RATING, .00000 lb

SMC's IS10 pressure switch is 16% lighter, and 11% smaller when compared to the IS1000.  The IS10 is RoHS compliant and CE marked.  Set pressure range is 0.1 to 0.4MPa (optional 0.1 to 0.6 MPa).  Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).For connecting to modular type FRL units , 100V AC/DC specifications , Service life

SMC's IS10 pressure switch is 16% lighter, and 11% smaller when compared to the IS1000.  The IS10 is RoHS compliant and CE marked.  Set pressure range is 0.1 to 0.4MPa (optional 0.1 to 0.6 MPa).  Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).For connecting to modular type FRL units , 100V AC/DC specifications , Service life

Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 30mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 12VDC L Plug Connector, Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -

Magnet: Built-in, Mounting: Front Flange, Bore Size: 16mm, Stroke: 60mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 12VDC L Plug Connector, Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -

Magnet: Built-in, Mounting: Axial Foot, Bore Size: 10mm, Stroke: 15mm, Cylinder Rod Motion: Normally Retracted, Valve Specifications: 12VDC L Plug Connector, Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -

Magnet: Built-in, Mounting: Axial Foot, Bore Size: 10mm, Stroke: 15mm, Cylinder Rod Motion: Normally Extended, Valve Specifications: 12VDC L Plug Connector, Light & Surge Suppressor: None, Auto Switch: Rail Mounting, Number: -