SMC Corporation of America
Elite Part Number Search
Search Results "PF3W540S-N06-1T-GR"

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None,

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: Calibration Certificate,

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -

Grease pack part number: GR-S-010 (10g), GR-S-020 (20g) Apply plenty of grease to the internal and external circumference of a new rod seal for replacement (See Table 4, P19). Fill the groove with grease. Refer to Page 21 for made to order product (XC85, X446). c) Mounting Mount taking care that the rod seal is in the right direction.

Grease pack part number: GRD -005 (5g), GR-D-010 (10g), GR-D-100 (100g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to mount the rod seal and improve sealing.

Grease pack part number for stainless steel cylinders Grease for food processing machines: GR-R-010 (10 g) 2. Do not wipe grease attached to the rotating part of the air cylinder. If grease attached to the rotating part is forcibly wiped off, it may cause malfunctions. If the cylinder is operated for a long period of time, the rotating part may become black.

(mm) CG5*N*SR CG5*N*SV CG5*A*SR CG5*A*SV 20 CG5N20SR-PS CG5N20SV-PS CG5A20SR-PS CG5A20SV-PS 25 CG5N25SR-PS CG5N25SV-PS CG5A25SR-PS CG5A25SV-PS 32 CG5N32SR-PS CG5N32SV-PS CG5A32SR-PS CG5A32SV-PS 40 CG5N40SR-PS CG5N40SV-PS CG5A40SR-PS CG5A40SV-PS NBR FKM NBR FKM GR-R-010(10g) 3-3-2. 1 2 3 4 5 21 3-4. 1. GR-R-010(10g) 2. 3. 4. 50mm/s 1. P18, 3-2-2. 2.

Grease pack number: GR-S-010 (10g), GR-S-020 (20g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to install the rod seal and improve sealing.

Grease pack number: GR-S-010 (10g), GR-S-020 (20g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to install the rod seal and improve sealing.

Grease pack number: GR-S-010 (10g), GR-S-020 (20g) 1) Rod seal Apply a thin layer of grease to all surfaces of the new seal to make it easy to install the rod seal and improve sealing.

Specified grease pack part number: GR-S-010(10g) When the O-ring for single acting normal open type or end boss type cap is replaced, it is necessary to remove the Type C retaining ring. 16 - 32, 40 1. Remove the retaining ring using the special tool and remove the cap. 2. Loosen the guide bolts and remove the guide. 3.