SMC Corporation of America
Elite Part Number Search
Search Results "PF3A802H-L2Q-MA"

30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal

() DC15 V(1 M) 1 (26.4 V ) NPN PNP 2 80 mA DC30 V(NPN ) 1 V (80 mA ) () 100 ms.500 ms1 s2 s 15 V( 1 k () (25 ) 1F.S. 420 mA() 600 (DC24 V) 50 () (25 ) 1F.S

*1: To use the power of the device, the total load current must be 500 mA or less.

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal

or less Data Weight 45 g Maximum load current: 80 mA NPN open collector Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D300, PF2W300, PF2W330) Maximum applied voltage: 30 V 2 outputs Environmental resistance Note 4) Output specifications Switch output PNP open collector Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (With load current of 80 mA) (PF2D301

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Rated Flow Range: 10 to 1000 l/min, Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: Yes, Flow Direction: -

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes)

less 200 mA or less 100 mA or less 100 mA or less Compatible encoder Incremental A/B phase (800 pulse/rotation) Protocol EtherCAT*2 EtherNet/IP*2 PROFINET*2 DeviceNet IO-Link Communication specifications Applicable system Version*1 Conformance Test Record V.1.2.6 Volume 1 (Edition 3.14) Volume 2 (Edition 1.15) Specification Version 2.32 Volume 1 (Edition 3.14) Volume 3 (Edition 1.13) Version

or less Discharge stop signal Connected to 0 V Voltage range: 5 VDC or less Current consumption: 5 mA or less Connected to +24 V Voltage range: 19 VDC to power supply voltage Current consumption: 5 mA or less Reset signal Input signal External switch signal 1 External switch signal 2 Discharge signal Max. load current: 40 mA Residual voltage: 1 V or less (Load current at 40 mA) Max. applied

Flow Rate and Sonic Conductance Model AS1002F-mA AS2002F-mA AS2052F-mA AS3002F-mA AS4002F-mA Tubing O.D.

Cushion valve G 2 x Rc P W V Port G E Width across flats KA TX D E B C H1 AL MM MB MA N 2 x 4 x J N TY B C Width across flats B1 A H K F TT ZZ + Stroke S + Stroke With rod boot d e 10.2 10.2 f h l [mm] Bore size [mm] A AL B B1 C D E F G H H1 J K KA MA MB MM N P S TT TX TY V W ZZ 32 22 19.5 46 17 32.5 12 30 13 13 47 6 M6 x 1 6 10 16 4 M10 x 1.25 27 1/8 84 17 48 49 4 6.5 135 40 30 27 52 22

Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200

Contact Protection Box Specifications CD-P12 CD-P11 Part no. 100 VAC 200 VAC Load voltage 24 VDC Note 2) 25 mA 12.5 mA Max. load current 50 mA Lead wire length Switch connection side 0.5 m Load connection side 0.5 m Note 3) (Example) D-F9PWL61 Part No. of Lead Wires with Connectors (Applicable only for connector type) Flexible lead wire specifications Contact Protection Box Internal Circuit