3 3 8 1.1 M V VX3334 -03 M V 4 VX3244 -03 1.6 M V VX3344 -03 For Vacuum Pad Orifice dia.
LVA Connection LVH 3 8 1 2 3 4 03 04 06 10 12 14 20 LVD Refer to the table (2) given below for availability. Thread 1 1 1 2 LVQ 1 4 1 2 Refer to page 17-3-16 for ordering coil only. LQ Thread type Nil T F N For 32A For 40A For 50A 32 40 50 Rc NPTF G NPT Flange LVN Refer to the table (1) given below for availability.
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
Type Symbol sensor Flow rate/temp. 5 Flow rate/temp. 5 L 1 IO-Link/switch output (N/P) None Integrated display type L2 1 IO-Link/switch output (N/P) Switch output (N/P) LT IO-Link/switch output (N/P) With temp. sensor L2T 1 IO-Link/switch output (N/P) Switch output (N/P) (IO-Link compliant 4) 1: Made to Order. 2: External input: resets the accumulated value, peak value and bottom value. 3
Example: SS3YJ5-20-03 .1 set (Manifold base) SYJ512-5LZ-M5.2 sets (Valve) SYJ500-10-1A.1 set (Blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (Manifold base) SYJ514R-5G.2 sets (Valve) SYJ500-10-3A .1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 4 Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
IRM 10 3 G ARJ A IR X465 0 AR425 to 935 Set pressure and quantity 0 1 2 0.2 MPa setting 1 to n pcs. 0.4 MPa setting 1 to n pcs. 0.8 MPa setting 1 to n pcs.
F (inch) Model N L1 L2 H (Width across flats) Port B min. bore Weight (g) L3 L4 L5 L6 P Q1 Q2 M KM12-03-35-10 KM12-03-35-6 6 87 10 40 65 5 32 1 4 29 18 29.5 19.5 10.6 12 16 6 17.46 10 110 6 95 10 121 6 102 10 61.5 72 KM12-07-35-10 KM12-07-35-6 48 82 31.25 10 19.5 31.5 21.5 13.2 13 17 7 17.46 1 4 1 4 73.5 92 KM12-09-36-10 KM12-09-36-6 52.8 97 37.5 12.7 23.7 37.7 25 15.2 15 18.5 9.5 22.22 5
Note 2) This filter does not include any companion flange, companion flange bolt, and O-ring. 4 x K depth L DRAIN (): Internal dimensions for FH342 type (mm) Model Weight (kg) d A B C D E F G H J J' K L M N P Q Threaded Rc Flange SSA FH340-03 FH340-04 FH342-06 FH342-08 FH34 -10 FH34 -12 FH341-16 FH440-03 FH44 -04 FH44 -06 FH44 -08 FH44 -10 FH44 -12 FH441-16 FH441-20 FH441-24 FH540-03 FH54
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
UNSIGNED8 Number of Channels 40x2:03 40x2:04 Channel 2 Channel 3 (Output setting value during communication fault) UNSIGNED16 0 to 0xF 40x3:0 Idle mode UNSIGNED8 Number of Channels 40x3:03 40x3:04 Channel 2 Channel 3 (Output setting during communication idling) Enum0800 0=Disable (Hold) 1=Enable (Fault value) 40x4:0 Idle value UNSIGNED8 Number of Channels 40x4:03 40x4:04 Channel 2
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
-06 12.8 6 39.3 18.5 63 15.2 41 29.5 17 55 27.8 23 43.8 21.8 48.8 42.8 37.8 5/16" AS321F-02-11 AS321F-03-08 31.8 15.2 41 8 17.9 43.3 21 67 18.5 57 29.5 3/8" 23 20.9 46.5 35.2 40.2 41.5 19 3/8 AS321F-03-07 AS321F-03-10 27.8 43.3 10 13.2 18.5 39.3 17 55 21 59 31.8 1/4" AS321F-03-09 AS321F-03-12 29.5 15.2 41 18.5 57 44.3 12 20.9 46.5 41.5 40.2 35.2 20.9 22 61 32.8 23 5/16" 3/8 AS321F-03-11 AS421F
-06 AS321F-03-07 6 1/4" 12.8 17 27.8 39.3 27.8 55 39.3 17 55 13.2 AS321F-03-08 AS321F-03-09 8 5/16" 15.2 18.5 29.5 41 23 29.5 57 41 18.5 57 19.8 45.4 40.4 40.2 35.2 15.2 3/8 45.4 40.4 40.2 35.2 19.8 23 3/8 AS321F-03-10 AS321F-03-11 31.8 43.3 21 59 17.9 10 18.5 21 43.3 31.8 59 3/8" AS321F-03-12 AS421F-04-11 12 3/8" 20.9 22 44.3 32.8 33.6 61 47.9 21 100 17.9 24 28.6 49.2 49.6 42.1 1/2 24.5
Thread (Cylinder ports and P/R ports) Rc(PT) N NPT T NPTF F G(PF) Dust Tight/Jet Proof (IP65) Optional IP65 model is available on valves with DIN connector electrical entry. How to Order Valve (Applicable to VQZ200/300 rubber style) VQZ335 5YZB 03 W IP65 rated No (Standard) (1) IP65 rated W Note 1) The pilot exhaust of the IP65 valves is common with main valve exhaust.
-02-A Y410-03-A Y510-03-A VHS40-02A VHS40-03A VHS20-01A VHS30-02A Pressure relief 3 port valve Note5) VHS40-06A Attachment VHS20-02A VHS30-03A VHS40-04A E300-04-A E300-03-A E300-02-A E400-02-A E200-01-A E400-04-A E400-03-A Piping adapter Note5) E100-M5-A E200-02-A E500-06-A E200-03-A E400-06-A IS10E-4002-A IS10E-3002-A IS10E-2001-A IS10E-4003-A Pressure switch with Note5) IS10E-2002-A IS10E
Nil Rc N NPT T NPTF F G Dusttight/Low Jetproof Type (IP65) DIN terminal is available with dusttight/low jetproof (IP65) type. How to order valves (Applicable to VQZ200/300 rubber seal with the exception of the external pilot type) VQZ335 5YZB 03 W IP65 compliant No (Standard) Nil Note) Compliant W Note) The pilot exhaust of the IP65 valves is common with main valve exhaust.
Safety Instructions Be sure to read Precautions for Handling Pneumatic Devices (M-03-E3A) before using. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2005 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing JR printing