Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 19.4 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 3.1 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 8.20000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR-HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 10.00000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR-HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 10.70000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 21.20000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR-HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 25.00000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 6.30000 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV, N67, 7.70000 lb
Back page 3 Related Products Dehumidification Dehumidification Refrigerated Air Dryer: Series IDF/IDU E Membrane Air Dryer: Series IDG Series Outlet air flow l/min (ANR) Standard dew point (C) IDG 1 to 100 IDG 3H to 100H IDG 30L to 100L IDG 60S to 100S 20 10 to 1000 15 25 to 1000 Series Applicable compressor Air flow capacity m3/min (ANR) 40 75 to 300 2.2 to 75 kW IDF 1E to 75E IDU 3E to
Air-hydro unit, series CC; Converter size (mm): 63, 100, 160; Small and large flow available; High cylinder operation speed; Air port size: 3/8 (63), 1/2 (100), 3/4 (160); Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L)
Air-hydro unit, series CC; Converter size (mm): 63, 100, 160; Small and large flow available; High cylinder operation speed; Air port size: 3/8 (63), 1/2 (100), 3/4 (160); Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L)
Hs A 26 B D-H7A1/H7B Auto switch 8.5 16 approx. Hs A 29 B (mm) D-C73 A D-H7A1/H7B B Hs A B Bore size Hs 7 6 22.5 6 5 22.5 7 6 25 6 5 25 8 7 28.5 7 6 28.5 14 12 32.5 13 11 32.5 20 25 32 40 Note) The above values should be used as a guide for detection at stroke end.
3 (L) 5 (Z) None (N) DC AC Perpendicular In-line 3-wire (NPN equivalent) A76H C76 5 V IC circuit Reed switch Solid state switch Grommet A72H A73H A72 A73 A73C C73 C73C 200 V 100 V 2-wire Yes Yes 12 V Relay, PLC Connector 24 V With diagnostic output (2-color indication) A79W Grommet 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F79W F7PW J79W F7BA F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV H7A1
Rail mounting Grommet C73 C80 C73C C80C 100V 12V Band mounting CDJ2B16-60-B No IC 100V 5V, 12V Relay PLC 2 wire Yes 24V 12V Connector No 24V 5V, 12V IC Diagnostic indication (2 color) Grommet Yes H7A1 H7A2 H7B H7C H7NW H7PW H7BW F79 F7P J79 3 wire (NPN) IC 5V, 12V Grommet 3 wire (PNP) 2 wire 12V Connector 3 wire (NPN) F79W F7PW J79W 5V, 12V IC Diagnostic indication (2 color) Relay PLC 3 wire
Auto Switch Internal Circuit D-H7A1 Weight (g) DC (+) Brown D-H7A1 D-H7A2 D-H7B Auto switch model Main circuit of switch Main circuit of switch Main circuit of switch 11 13 13 0.5 OUT Black Lead wire length (m) 50 57 57 3 81 92 92 5 DC () Blue Dimensions D-H7A2 DC (+) Brown OUT Black DC () Blue Indicator light D-H7B 3.5 mounting hole OUT (+) Brown Most sensitive position OUT () Blue 8-30-
D-H7A1/D-H7A2/D-H7B Band Mounting Style . D-G59/D-G5P/D-K59 Band Mounting Style. D-H7C Band Mounting Style. D-G39/D-K39 Band Mounting Style. D-G39A/D-K39A Band Mounting Style . D-F79/D-F7P/D-J79 Rail Mounting Style. D-F7NV/D-F7PV/D-F7BV Rail Mounting Style . D-J79C Rail Mounting Style. D-F59/D-F5P/D-J59/D-J51 Tie-rod Mounting Style . D-G39C/D-K39C Tie-rod Mounting Style.
Proper auto switch mounting position (Detection at stroke end) D-C73 D-H7A1/H7B Auto switch Auto switch Approx. Hs Approx. Hs 16 16 A 26 B A 29 B (mm) D-C73 A D-H7A1/H7B B Hs A B Bore size Hs 2.5 2.5 17 1.5 1.5 17 3 3 20.5 2 2 20.5 Note) The above values should be used as a guide for detection at stroke end.
Proper auto switch mounting position (Detection at stroke end) D-C73 D-H7B/H7A1 approx. Hs approx. Hs D-B54 D-K59/G59 approx. Hs approx.
D-H7A1/D-H7A2/D-H7B Band Mounting Style . D-G59/D-G5P/D-K59 Band Mounting Style.