Order Clean series 12 Special treatment on sliding part Bore size (mm) 12 R E A 25 300 Cylinder stroke (mm) Type Port type Symbol Nil TN TF Rc NPT G Model Bore size (mm) Maximum manufacturable stroke (mm) Port size Lubrication Model Standard stroke (mm) Rc1/8 NPT1/8 G1/8 Rc1/4 NPT1/4 G1/4 12-REA25 12-REA32 25 32 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 12-REA40 12-REA50 50 1300
charge kg 0.3 0.32 Control method Compressor ON/OFF Ambient temperature/Humidity/Altitude Note 1), 11) Temperature: 5 to 35C, Humidity: 30 to 70%, Altitude: less than 3000 m Circulating uid Note 2) Tap water, 15% ethylene glycol aqueous solution Set temperature range Note 1) C 10 to 30 Cooling capacity Note 3), 11) (50/60 Hz) W 1000/1200 For option -T: 900/1100 1400/1600 For option -T: 1300
/Weight C [dm 3/(sbar)] b Cv 1 2 (P A) 2 3 (A R) Weight (g) Note) Port size Model C [dm 3/(sbar)] b Cv 3.5 4.2 7.9 8.9 11.9 15.1 1/8 1/4 1/4 3/8 3/8 1/2 0.26 0.22 0.21 0.16 0.21 0.21 0.8 1.0 1.8 2.2 2.7 3.6 3.6 4.2 7.2 8.9 11.8 15.3 0.26 0.23 0.27 0.20 0.20 0.22 0.9 1.0 1.8 2.1 2.7 3.7 118 114 237 229 501 484 VPA342 VPA542 VPA742 Note) Values without brackets Caution Refer to page 1300
Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, WATER COOLED, OTHERS, HRS THERMO-CHILLERS, 22, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
Fluid:air; CO 2 ; nitrogen gas; freon 11, 113, 114; turbine oil, hydraulic fluid, argon, helium, Proof pressure: 1.5MPa, Operating pressure range: 0 to 1MPa, Effective area: 13 to 770mm 2, Coil rated voltage: AC(50/60Hz) 100V, 200V, others (option); DC 24V, others (option), Ambient temperature: -5 to 60°C (no freezing), Process valve, 2 PORT PROCESS VALVE, J07, 1300 lb
PARALLEL SUPPLY/RETURN TYPE MANIFOLD, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 1300 lb
Cylinder, Air, Non-Rotating, ISO ROUND BODY CYLINDER, C75, C76, 273, 1300 lb
Pilot Op 2 Port Solenoid Valve, (N.C.), 2 PORT VALVE, 1300 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, GUIDED CYLINDER, 1300 lb
Variations include energized open (N.C) and energized closed (N.O) valves, BC6 body material and NBR, FPM seal materials., Valve, Media (N.O.), 2 PORT VALVE, 1300 lb
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, WATER COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 88.18490 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
typeGuide typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB25S2300, 400, 500600, 700, 800900, 1000, (1100)1200, (1300
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 88.18490 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, GUIDED CYLINDER, 1300 lb
Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, VVD, 1300 lb
115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO CHILLER, AIR COOLED, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300