0x097F (2431) 0x0980 (2432) 0x0981 (2433) 5 R/W Line name 5th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 6 R/W Line name 6th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 7 R/W Line name 7th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) 8 R/W Line name 8th letter dot Y U8 0x00 0: OFF (dot OFF) 1: ON (dot ON) (0) Set the economy mode. 0: OFF 1: ON 0x0960 (2400
type type type Refrigerant R407C(HFC) Quantity of refrigerant kg 0.35 0.3 0.36 0.31 0.36 0.31 Control method PID control Ambient temperature and humidity2 Temperature: 5 to 40oC18 Humidity: 30 to 70% Circulating fluid3 Tap water, Ethylene glycol aqueous solution 15%5 Operating temperature oC 5 to 40 range2 Circulating fluid system Cooling capacity4 (50/60Hz) W 1100/1300 1700/1900 2100/2400
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
OFF. 3 stop (2400 bps ~ 38400 bps) (9600 bps) Thermostat alarm Occurs when the thermostat that detects excessive heating begins operating. Temp.control Turn ON Main power switch again AL7 pump and fan Loosen the reservoir cap to help draining. (Do not remove the cap) stop 0.0 to 110.0 % 2.
To drain from the piping, blow air (0.05MPa, about 1 minute) from the 10.2 Troubleshooting 2.4 ~ 38.4 9.6 2 Integral Time (2400 bps ~ 38400 bps) (9600 bps) circulating fluid OUT to IN port. Close the reservoir cap while blowing. Code Cause Countermeasure setting Clean air filter periodically to avoid declining performance.
indication on display) Sets target temp. for control. 0.0 to 50.0C (0.1C) 25.0 1.0 to 60.0C (0.1C) 60.0 -9.99 to 9.99C (0.01C) 0.00 -9.9 to 49.0C (0.1C) -9.9 10 to 999% (1%) 200 0.0 to 10.0C (0.1C) 1.5 0.0 to 10.0C (0.1C) 1.5 2 PB Range Sets PB (Proportional Band) range used for PID control. 0.3 to 9.9C (0.1C) 3.0 0.0 to 99.9sec (0.1sec) 0.0 None, Odd, Even None On, Off Off 600, 1200, 2400
PA06 1 262144 (Position control mode) 2000 1200 600 2400 1600 800 3000 2000 1000 Electronic gear denominator *3.
Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
Baud Rate Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. B a u d R a t e M O D E < 1 2 0 0 b / s 3. Parity Bit Setting range : Without (no parity), Odd, Even Indicated content : Parity bit (Ex. : Without) Function : Sets parity bit for communication.
Temperature display) impair the performance. 600, 1200, 2400, Selects control operation mode from those shown below. 0: Pump stop (No control) 1: Normal operation 2: AT(auto tuning) 3: Learn (learning control) 4: External (external tune control) 5: SeriRem (Serial remote) 5:Serial remote is displayed when choose the Modbus communication. of the tank and the chassis near the tank could be
PA06 1 262144 (Position control mode) 2400 1600 800 3000 2000 1000 2700 4200 Electronic gear denominator *3.
Stop filling once the level of fluid reaches the H mark. 600, 1200, 2400, [AT]: Used to start auto tuning in auto tuning mode 5. Turn on the power switch to fill the piping with the fluid. 6.
FLANGE 3 150 174 R134a 890 3 3/4 PDE260-S 1007 7.5 8.5 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 990 5 PDE310-S 1200 7.8 8.8 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 1060 5 PDE410-S 1483 13.5 15.0 27.6 78.7 68.8 19.7 21.3 460/3/60 FLANGE 4 150 174 R134a 1180 6 PDE510-S 1840 15.5 17.8 27.6 78.7 68.8 19.7 21.3 460/3/60 FLANGE 4 150 174 R134a 1200 8.5 PDE610-S 2400
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 800 (8" - Large Bore), Stroke: 2400 (24"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 325 (3 1/4"), Stroke: 2400 (24"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)
Retraction stroke end Extension stroke end Retraction stroke end MXQR 6 MXQR 8 MXQR12 MXQR16 MXQR20 MXQR25 5 6 5 10 10 14 200 180 140 120 100 10 10 10 23 23 30 315 250 210 170 140 385 23 25 23 35 30 47 745 490 450 380 340 335 655 40 45 40 60 53 75 1400 1250 835 735 670 610 605 1000 65 80 65 115 120 170 2900 2650 2350 1400 1200 1100 1100 1100 1750 110 130 110 180 140 220 4700 4300 3450 2400
Series: NCDA1 (Standard w/ Magnet), Mounting: B (MX0, Basic), Bore Size: 800 (8" - Large Bore), Stroke: 2400 (24"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical
Series: NCDA1 (Standard w/ Magnet), Mounting: B (MX0, Basic), Bore Size: 325 (3 1/4"), Stroke: 2400 (24"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: F (Flanged), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB5 (Oversized Rod Cylinder)
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 325 (3 1/4"), Stroke: 2400 (24"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: FM (Full Male, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen.
Description Material NVFR21 00 NVFR2200 NVFR2300, 2400, 2500 G) Gasket NBR AXT624-20-2 AXT624-20-2 AXT624-20-2 0 Valve mounting bolt Steel e Pilot Ass'y AXT624-26 (M3X31) AXT624-26 (M3X31) AXT624-26 (M3X31) Refer to "Pilot Operator Ass'y/How to Order" on page 8. Series NVFR2000:Base Mounted 1Ype Pilot Operator Ass'y/ How to Order SF4 ~ Voltage L..-..