The XC8/XC9 adjustable stroke options feature an infinitely adjustable stop position within the adjustable range. XB9 low speed & XC8/XC9 adjustable stroke options; Double acting single rod; Bore sizes: 1½, 2, 2½, 3¼, 4"; Strokes from 1 to 73"; 12 mounting options

The XC8/XC9 adjustable stroke options feature an infinitely adjustable stop position within the adjustable range. XB9 low speed & XC8/XC9 adjustable stroke options; Double acting single rod; Bore sizes: 1½, 2, 2½, 3¼, 4"; Strokes from 1 to 73"; 12 mounting options

The MGPM/L-XC8 is an adjustable extend stroke type where the MGPM/L-XC9 allows for stroke adjustment on the retract stroke. The MGPM/L-XB13 is a compact body actuator integrated with internal guide shafts with the ability to operate smoothly at low speeds (5 to 50mm/s).

The CM2-Z series offers a variety of mounting options Double acting, single rod w/XB9, XC8, XC9, XC10, XC11 or XC12 ; Double acting double rod w/XC10 ; XB9 is capable of low speeds range of 5 to 50 mm/sec ; XC8 option has adjustable stroke in the extend direction ; XC9 option has adjustable stroke in the retract direction ; XC10 is dual stroke with 4 positions (double rod type) ; XC11 is

The CM2-Z series offers a variety of mounting options Double acting, single rod w/XB9, XC8, XC9, XC10, XC11 or XC12; Double acting double rod w/XC10; XB9 is capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke

Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20

Double acting, single rod w/XB13, XC8, XC9, XC10 or XC11; Double acting double rod w/XC10; XB13 capable of low speeds range of 5 to 50 mm/sec; XC8 option has adjustable stroke in the extend direction; XC9 option has adjustable stroke in the retract direction; XC10 is dual stroke with 4 positions (double rod type); XC11 is dual stroke with 3 positions (single rod type); Bore sizes (mm): 20

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, PC, 2.5 INCH NCA1 OTHERS (COMBO), .00000 lb

Part Number Description: AUTO-SWITCH   Product Line: A   Product Line Description: ACTUATOR   Family Code: 572   Family Description: AUTO-SWITCH ACCESSORY   Class Code: 22   Part Code: 1   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, TypeModelElectrical entryFeaturesSolid stateD-F59/F5P

Description: AUTO-SWITCH W/CONNECTOR   Product Line: A   Product Line Description: ACTUATOR   Family Code: 572   Family Description: AUTO-SWITCH ACCESSORY   Class Code: 22   Part Code: 1   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, TypeModelElectrical entryFeaturesSolid stateD-F59/F5P

Ambient temperature -1060 Shock resistant 300 m/s2 Current leakage i None Enclosure ii Standard: IEC60529, watertight: IP67(JISC0920) -28- Table12 Solid state auto switch specification Indication Auto Load Applicable light Wiring (Output) Electrical switch voltage load (illuminated entry part no. when ON) DC5V,12V D-F59 DC24V 3-wire (NPN) IC circuit Relay PLC 3-wire(PNP) DC5V,12V D-F5P

voltage Applicable Auto Switch Lead wire length (m) Lead wire length (m) Applicable model Function Mounting Electrical entry Electrical entry 1.0 0.5 Applicable model Function Mounting 3.0 3.0 1.0 0.5 F79, F7P, J79 F7NV, F7PV, F7BV F79W, F7PW, J79W F7NWV, F7BWV F79F F7BA F7BAV F7NT P4DW H7A1, H7A2, H7B G59, G5P, K59 H7NW, H7PW, H7BW G59W, G5PW, K59W H7NF, G59F H7BA, G5BA G5NT G5NB F59, F5P

Electrical entry Type Model Features D-A53/A56 D-A64/A67 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W D-F5BAL D-F5NTL D-Y69A/Y69B/Y7PV D-Y7NWV/Y7PWV/Y7BWV Grommet (In-line) Reed switch Without indicator light 2-color indication Water resistant (2-color indication) With timer 2-color indication Grommet (In-line) Solid state switch Grommet (Perpendicular) With pre-wire connector is available for

MWBW MWB-UT Model Selection Double Acting, Single Rod Double Acting, Double Rod Lock Unit Made to Order Auto Switch Type Model Electrical entry Features D-M9NV/M9PV/M9BV D-Y69A/Y69B/Y7PV D-M9NWV/M9PWV/M9BWV Diagnostic indication (2-color indicator) D-Y7NWV/Y7PWV/Y7BWV D-M9NAV/M9PAV/M9BAV Water-resistant (2-color indicator) D-P3DW Magnetic field-resistant (2-color indicator) D-P4DW D-F59/F5P

A33 A34 A44 A33C A34C A44C Conduit terminal PLC DIN connector PLC Diagnosis indication (2 color) B59W A59W Grommet 3 wires (NPN) 3 wires (PNP) G59 F59 5V 12V IC 24V Part No. of Cylinder with Built-in Magnet G5P F5P Grommet 100V 200V J51 If ordering cylinder with built-in magnet without an auto switch, symbol for anto switch is Nil. Ex.)

Wiring (output) Style Special function 0.5 ( ) 3 (L) 5 (Z) None Tie rod Band DC AC 3 wire (Epuiv. to NPN) P P P P P P P P P P A56 IC 5V Yes No Yes Yes A53 A54 A67 A64 12V PLC Grommet 100V, 200V Relay, PLC 12V Reed switch Solid state switch P P IC 5V, 12V PLC 200V 12V Relay, PLC 2 wire 24V P P P A33 A34 A44 PLC Terminal conduit 12V 100V, 200V Relay, PLC DIN terminal P P P P P P A59W F59 F5P

) Indicator Wiring (Output) Applicable load Auto switch model Special function Style Electrical entry 0.5 () 3 (L) 5 (Z) AC DC 3 wire (Equiv. to NPN) Yes IC circuit A56 5V A53 12V Reed switch Solid state switch Grommet A54 12V 100V, 200V Relay PLC A67 2 wire 24V 5V, 12V IC circuit No A64 200V 12V A59W Yes Diagnostic indication (2 color) F59 3 wire (NPN) IC circuit 5V, 12V 24V F5P

Indicator Wiring (Output) Applicable load Auto switch model Special function Style Electrical entry 0.5 () 3 (L) 5 (Z) AC DC 3 wire (Equiv. to NPN) IC circuit A56 5V Yes A53 12V Reed switch Solid state switch Grommet A54 12V 100V, 200V Relay PLC A67 24V 2 wire 5V, 12V IC circuit No A64 200V 12V A59W Yes Diagnostic indication (2 color) F59 3 wire (NPN) IC circuit 5V, 12V 24V F5P

Electrical entry (Fetching direction) D-A90V Without indicator light Grommet (Perpendicular) D-A93V, A96V D-Z73, Z76 Reed D-A53, A56 Grommet (In-line) D-A64, A67 Without indicator light D-Z80 D-M9NV, M9PV, M9BV D-Y69A, Y69B, Y7PV Grommet (Perpendicular) D-M9NWV, M9PWV, M9BWV 2-color indication D-Y7NWV, Y7PWV, Y7BWV D-M9NAVL, M9PAVL, M9BAVL Water resistant (2-color indication) Solid state D-F59, F5P

90/97 D-A90/A93/A96 D-A90V/A93V/A96V 2.11-13 Grommet 2.11-14 D-90A/93A Direct mounting 2.11-15 D-R731/R732 2.11-15 D-R801/R802 MHZ2 2.11-16 D-R731C/R732C Connector 2.11-16 D-R801C/R802C MHZJ2 2.11-17 Grommet Rail D-A79W 2 color indication MHQ Grommet Tie rod 2.11-18 D-A59W 2.11-19 D-F79/F7P/J79 MHL2 Grommet 2.11-20 D-F7NV/F7PV/F7BV Rail Connector 2.11-21 D-J79C MHR Grommet 2.11-22 D-F59/F5P