Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 5", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 12", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Magnet: Built-in, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 12", Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Series: Standard w/ Magnet, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2 1/2", Stroke: 14", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Intermediate Male, Threaded, Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Piston Rod and

Part Number Description: POSITIONER PNEU-PNEU LEVER   Product Line: I   Product Line Description: INSTRUMENTATION   Family Code: 812   Family Description: IP5000/6000 POSITIONER   Class Code: DB   Part Code: 1   Reference Code:  K   Click here to report information errorImage shown may not match exact part number

(When reversed output is selected, the sub display (left) shows [n1L/n2L] and [n1H/n2H].) 16000 L/min 12000 L/min 20 L/min 6000 L/min Additional range 3 Blue DC(-) DC(-) WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-M090 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS-R Series 8.2 Inspection and Cleaning 8-5 HRX-OM-W058 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-R016 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Panel Pump Fig. 8-3 Leak check HRL Series 8.2 Inspection and Cleaning 8-5 HRX-OM-X037 Chapter 8 Control, Inspection and Cleaning 8.3 Operation Stop for an Extended Period of Time If there is a concern that the product will not be operated for an extended period of time or there

The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours. Water leak inspection point Fig. 8-3 Check for water leakage from the pump HRLE Series 8.2 Inspection and Cleaning 8-5 HRX-OM-Z002 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection during winter season Keep the power supply ON for this function.

PA07 1 (Positioning mode) 20 12000 6000 24000 16000 8000 30 20 10 Function selection A-3 PA21 0001 2001 (J3 electronic gear setting value compatibility mode) Feel length multiplication (STM) (Multiplier) PT03 0 0 ((<1000 stroke)/0001 (>1000 stroke) Home position return type PT04 0010 3 (Stopper type) Home position return direction PT04 0010 1 (Motor side) Home position return Speed (rpm)

. -29No.EX-OMN0009-G Network communication specifications Item Specifications Protocol PROFIBUS DP (EN50170, EN50254) Transmission speed 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000 (kbps) Device type DP slave EX260-SPR1/-SPR2/-SPR5/-SPR6 32 outputs Number of outputs EX260-SPR3/-SPR4/-SPR7/-SPR8 16 outputs EX260-SPR1/-SPR2 Smc_1430.gsd EX260-SPR3/-SPR4 Smc_1431.gsd Configuration

. -26No.EX-OMK0006-C Overview object dictionary for device profile specific area Index Sub-Index Object Name Type Acc Default Digital Input Module 6000 ARRAY Read Inputs 8-bit 0 VAR Number of inputs 8-bit Unsigned8 ro 1 VAR Read Inputs 1h to 8h Unsigned8 ro 2 VAR Read Inputs 9h to 16h Unsigned8 ro 3 VAR Read Inputs 17h to 24h Unsigned8 ro 4 VAR Read Inputs 25h to 32h Unsigned8 ro 6100 ARRAY

Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points

Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 -19No.EX-OMN0028-B Setting and Adjustment Switch setting (1)Loosen the display cover screw (indicated by arrow). (2)Open the display cover using a flat head screwdriver, etc. (3)Set the switch using a small watchmaker's screwdriver with a thin blade, referring to the setting

Network length Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 Max. cable length [m] 1200 1000 Communication speed [kbps] 500 1500 3000 6000 12000 Max. cable length [m] 400 200 100 : Maximum cable length differs depending on the specifications of a cable. The above cable length is based on type A cable.

. *3 Double clevis type: Use within the stroke limit of 400 or less and the thrust limit of 6000 or less.

. -30 -20 -10 0 0 1000 2000 3000 4000 5000 6000 Piping length [mm] mm Fig. A. Vacuum pressure for piping (ZK215) Tube TU0805 or T0806 Tube TU1065 or T1075 Nipple KQ2N08-99 Straight type of different diameter KQ2H08-10A Fig. B Example of piping -74No. ZK2-OM01301 In addition, the exhaust port should not be blocked or pressurized.

Specifications SL5402 1 to 30 psig (0.007 to 0.2 MPa) SL5410 2 to 100 psig (0.014 to 0.7 MPa) SL5406 1 to 60 psig (0.007 to 0.4 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas Vacuum to 1000 psig (6.9 MPa) 3000 psig (20.7 MPa) 6000 psig (41.4 MPa