Bore size 12 12 mm 16 16 mm 20 20 mm 25 25 mm 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm Cylinder stroke [mm] Refer to Standard Strokes on page 3. Port thread type Nil M thread 12 to 40 Rc 50 to 100 TN NPT TF G Applicable Auto Switches/Refer to the WEB catalog or Best Pneumatics for further information on auto switches.
Guide Table Series MGF 40, 63, 100 How to Order Port thread type Rc NPT G Nil TN TF MGF 63 30 M9BW Made to Order Refer to page 413 for details. Guide Table Bore size/ Standard stroke (mm) Number of auto switches 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 2 pcs. 1 pc. "n" pcs.
Thread type Opening/Closing stroke (mm) Cylinder bore Symbol Type 10 20 40 60 16 30 60 80 20 40 80 100 25 50 100 120 32 70 120 160 40 100 160 200 Symbol Nil 10 to 25 M thread Rc NPT G Nil 1 2 TN TF 32 to 40 Double acting Action D Applicable Auto Switch/Refer to pages 761 to 809 for further information on the auto switches.
light only) With energy saving circuit MVGQ 12/16 10, 20, 30, 40, 50, 75, 100 100 V 0.78 (With indicator light: 0.81) M L 20, 30, 40, 50, 75, 100 125, 150, 175, 200 110 V [115 V] 0.86 (With indicator light: 0.89) [0.94 (With indicator light: 0.97)] MVGQ 20 Apparent power (2) CV AC (VA) Intermediate stroke (mm) 200 V 1.18 (With indicator light: 1.22) MVGQ As for the intermediate strokes (by
Also, when exceeding the air cushion stroke ranges on page 1191, the piston speed should be 100 to 200 mm/s. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 1191.
3-Position Rotary Table MSZ Series Size: 10, 20, 30, 50 CRB2 How to Order CRB1 MSU MSZA A M9BW 10 High precision type CRJ MSZB A M9BW 10 Basic type CRA1 Number of auto switches CRQ2 Nil n 2 pcs. n pcs.
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 0 0 40 20 50 30 10 80 60 40 20 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
Piston Speed 40 Without stroke adjusting unit 16 25 Bore size (mm) Note 1) 100 to 1000 mm/s L unit and H unit Stroke adjusting unit 100 to 1500 mm/s Note 1) When exceeding the air cushion stroke ranges on page 1094, the piston speed should be 100 to 200 mm/s. Note 2) Use at a piston speed within the absorption capacity range. Refer to page 1094.
V 100 V or less 100 V, 200 V 200 V or less 24 V or less IC circuit Grommet Relay, PLC 12 V Connector 2-wire 24 V IC circuit PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state
Guide Cylinder/Compact Type 20, 25, 32, 40, 50 Series MGC How to Order MGC 100 L R M9BW B 32 Guide Cylinder (Compact Type) Made to Order Refer to page 393 for details. Bearing type M L Slide bearing Ball bushing bearing Number of auto switches Mounting style Nil S n 2 pcs. B F Basic style 1 pc. Front mounting flange style n pcs.
Port Switch mounting groove 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Because piping ports and auto switch grooves are provided on both sides, only the adjuster part of the centralized adjuster is symmetric.
Rotary Angle Port side During unclamping (Extension end) 80 to 100 (9010) L type (Counterclockwise) During unclamping (Extension end) 80 to 100 (9010) R type (Clockwise) Theoretical Output Operating pressure (MPa) Unit: N Bore size (mm) Rod size (mm) Operating direction Piston area (cm2) 0.8 1.1 1.5 2.0 2.0 3.1 3.8 4.9 6.0 8.0 10.6 12.6 16.5 19.6 28.0 31.2 1.0 85 113 151 201 201 314 378 491
Compact Cylinder: Standard Type Double Acting, Single Rod Series CQS 12, 16, 20, 25 How to Order B D 30 20 CQS M9BW B D 20 30 CDQS With auto switch Made to Order Refer to page 552 for details.
V 12 V 5 V, 12 V Grommet No Relay, PLC 100 V or less Yes 100 V, 200 V No 200 V or less 2-wire 24 V PLC Terminal conduit 12 V Relay, PLC Yes 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.
Non-rotating Double Power Cylinder 20, 25, 32, 40, 50, 63, 80 Series MGZ How to Order 40 M9BW 100 Z MGZ Made to Order For details, refer to page 429. Mounting style Nil L F G Basic style Transaxial foot style Rod flange style Head flange style Number of auto switches 2 pcs. 1 pc. n pcs.
M9PWV M9BWV M9NAV1 Solid state auto switch Reed auto switch 5 V, 12 V 12 V IC circuit Diagnostic indication (2-color indicator) Relay, PLC 5 V, 12 V 12 V IC circuit Yes Yes No Grommet 24 V Water resistant (2-color indicator) 5 V, 12 V IC circuit M9PAV1 M9PA1 M9BAV1 M9BA1 12 V A96V A96 5 V 12 V IC circuit Grommet 24 V A93V2 A93 A90 100 V Relay, PLC 2-wire A90V IC circuit 100 V or less 1 Water
Hydraulic Cylinder 20, 25, 32, 40 CHN Series 7 MPa CHQ How to Order CHK CHN CHN CHN 25 100 M9BW L C CHM Auto switch mounting bracket Note) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.) Applicable to 20 only.
Rotation angle 90 180 80 to 100 170 to 190 Applicable Auto Switches/Refer to pages 797 to 850 for detailed auto switch specification.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
IC circuit 5 V A96V A96 3-wire (NPN equivalent) Yes 100 V 12 V Grommet A93V A93 Relay, PLC 24 V 2-wire IC circuit A90V A90 5 V, 12 V 100 V or less Solid state auto switches marked with are produced upon receipt of order.