SMC Corporation of America
Elite Part Number Search
Search Results "MXF20-75-A90"

45, 60, 75, 100, 125, 150, 175, 200 Standard Non-lube Double acting Single rod 15, 30, 45, 60 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.

30 1 5.5 11 62 12.5 17.5 73 14 9 23 92 23 DCY1SG20-Z RJ1007LN 40 1.5 73 M6 x 1 Rc1/8 NPT1/8 G1/8 70 90 90 38 4.5 9 16.5 21.5 M10 x 1 87 18.5 13.5 32 111 23 CY1SG25-Z RJ1412LN 40 1.5 73 M6 x 1 Rc1/8 NPT1/8 G1/8 70 99 90 42 4.5 9 16.5 21.5 M14 x 1.5 96 18.5 13.5 32 111 44 -X CY1SG32-Z RJ2015HN M8 x 1.25 Rc1/8 NPT1/8 G1/8 40 75 119 110 50 3 5.5 11 91 18.5 24.5 M20 x 1.5 116 18.5 12.5 31 134

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style . D-90A/D-93A Direct Mounting Style . D-R73/D-R80 Direct Mounting Style. D-R73xC/D-R80xC Direct Mounting Style . 2-color Indication Type Reed Switch . D-A79W Rail Mounting Style . D-A59W Tie-rod Mounting Style . Solid State Switch. General Purpose Type. D-F79/D-F7P/D-J79 Rail Mounting Style. D-F7NV/D-F7PV/D-F7BV Rail Mounting Style .

Same surface 75 Note 1) Confirm that it is possible to secure the minimum bending radius of 10mm of the auto switch lead wire before use. Note 2) Confirm that it is possible to securely set the auto switch(es) within the range of indicator green light ON range before use. For in-line entry type, please also consider Note 1) shown above.

Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at

MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 20, 30, 40, 50, 75, 100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Piston area (mm2) Operating direction 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 MGC Made to Order Specifications (For details

-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.

-XA< Tie-rod, cushion valve, tie-rod nut, etc. made of stainless steel -XC7 (mm) Standard stroke Bore size Long stroke (L and F only) -XC8 -XC14 -XC15 -XC30 Adjustable stroke cylinder/Adjustable extension type 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 Change of trunnion bracket mounting position Change of tie-rod length Rod trunnion 40 800 25, 50, 75, 100, 125, 150

Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600

Auto switches are not mounted, but rather packaged together with the cylinder for shipment. 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 12, 16 20 25 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32, 40 Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder.

L 3 m Connector Nil w/ connector Stroke(mm) Made To Order Fluoro rubber packing (Ex.) 2-2-2 Applicable Auto-Switch Models Z w/o connector 25, 50, 75, 100 Mark Auto-Switch Model Mark Auto-Switch Model Mark Auto-Switch Model A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW 2-color D-M9PW A96 Reed D-A96 M9B Solid State D-M9B M9BW Indication Solid State D-M9BW A90V Auto-Switch D-A90V

W Mounting: Basic, Flange, Foot (mm) Auto switch model D-A90 D-A96 D-A9V D-M9 D-M9W D-M9V D-M9WV D-A93 Bore size W 4 6 4 6 6 4 2 4.5 10 2.5 0.5 0 1 16 2.5 0.5 0 1 Mounting: Clevis, Trunnion (mm) Auto switch model D-M9V D-M9WV D-A9 D-A9V D-M9 D-M9W DBore size W 4 -X 6 1 0 10 0 0 Individual -X 16 0 0 0 (zero) denotes the switch does not protrude from the end surface.

Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not

(L) D-A90(L) Reed auto switch (Not applicable to flange size 16) A93(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) H0 5 to 150C H4 With 100C heater H5 With 120C heater Hightemperature type * Size 16 is not applicable to H4, H5.

(L) A93(M)(L)(Z) M9// D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) Nil XL H0 Solid state auto switch y Number of auto switches/Detecting position XLQ Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

A96 A96V 5 V IC circuit Grommet Yes A93 A90 A93V A90V IC circuit 100 V Relay, PLC 2-wire 24 V 12 V No 100 V or less Lead wire length symbols: 0.5 m .Nil (Example) M9NW 1 m . M (Example) M9NWM 3 m . L (Example) M9NWL 5 m . Z (Example) M9NWZ Solid state auto switches marked with a symbol are produced upon receipt of order.

.) < Applicable Auto switches > Solid state auto switch D-M9N(V)-900M9P(V)-900M9B(V)-900 D-M9NW(V)-900M9PW(V)-900M9BW(V)-900 Reed auto switch D-A90-900 Fig 4. How to Mount and Move the Auto Switch Fig 4.