/2400/4800/9600/19200 1200/2400/4800/9600/19200 Character code ASCII ASCII Interface 2-wire 3-wire Parity Without/Odd/Even Without/Odd/Even Start bit 1 bit 1bit Data length 7/8 bit 7/8 bit Stop bit 1/2 bit 1/2 bit BCC check Disable /Enable Disable/Enable Address 1 to 99 1 to 99 The settings are as underlined at the time of shipment from the factory. 7.4.2 Communication Procedure This product
2400, 4800, 9600, 19200b/s 1200 3 I Constant Sets integral time used for PID control. 1 to 999sec (1sec) 40 0,1,2 1 -100 to 100% (1%) 4 Data Length Sets data length for communication. 7Bits, 8Bits 8 0 to F (Hex decimal) 0 5 Stop Bit Sets stop bit for communication. 1Bit, 2Bits 1 No.
H 4 S y m b o l Initial power/ Power 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 consumption (W) Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
/350 / AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10 15 20 25 30 Ass'y ( Ass'y 30 8 XL-OMV0002 4 4-1.162540 Assy SUS304 SUS316L ( SUS304) ( A6063) C D C E E (KF ) Fn J H B A G A mm A B C D E Fn G H J
/350 / AC200V 2400/150 3200/220 4800/350 XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1 PTC 200V PTC 200 150 100V PTC 0 5 10 15 20 25 30 ( 30 10 XL-OMY0002 . 1 S 12 ( SUS304 M 3 M SUSU316L 8 11 SUS304 2 7 A6063 6 9 6 9 10 9 5 SUS304 4 5 10 4 10 S O S O XLD-25 XLD-40,XLD-50,XLD-160 XLD
10 Feel length multiplication (STM) (Multiplier) PE02 0 0 ((<1000 stroke)/0001 (>1000 stroke) Home position return type PE03 0010 3 (Stopper type) Home position return direction PE03 0010 1 (Motor side) Home position return Speed (rpm) PE04 500 90 150 300 75 113 225 60 90 180 Home position return/JOG operation Accelerationeration/Deceleration time constants (msec) PE07 100 1000 600 300 1200
command time Step repeat command end Step repeat command start Incremental move command Dwell command time Step repeat command end Program end 1000[r/min] 20[ms] 1000[10STMm] 100[ms] 3 [times] 100[10STMm] 100[ms] 2 [times] 200[10STMm] 100[ms] a) b) c) d) e) f) d) Incremental move command (200 10STM m) b) Incremental move command (100 10STM m) Forward rotation 0r/min Servo motor speed 1100 1200
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
Baud Rate Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. B a u d R a t e M O D E < 1 2 0 0 b / s 3. Parity Bit Setting range : Without (no parity), Odd, Even Indicated content : Parity bit (Ex. : Without) Function : Sets parity bit for communication.
high. 5 Baud Rate Sets baud rate for communication. 3) Confirm there is no leakage of circulating fluid and check the condition 4800, 9600, 1200 Fluid other than water or Ethylene Glycol (up to 20%) should not be 19200b/s of the piping (e.g. no tight bends or crushed pipes).
18 50 50 30 60 60 30 60 60 40 70 80 200 Work load [kg] Vertical 8 16 30 9 19 37 12 24 46 19 38 72 115 Force [N] Note2) (Set value LEY25S/32S15 to 30%) (Set value LEY63S 15 to 50%) (Set value LEY25T/32T12 to 24%) (Set value LEY63T 12 to 40%) 1003 65 127 242 79 154 294 98 192 385 368 156 304 573 131 255 485 157 308 588 197 736 521 1012 1910 3343 Actuator specifications to 300 900 450 225 1200
Maximum stroke (mm) Basic Bracket Head side flange, Foot, Single clevis Rod side flange Double clevis Bore size Center trunnion 125 1000 or less 1600 or less 140 1000 or less 1600 or less 160 1200 or less 1600 or less 180 1200 or less 1569 or less 200 998 or less 250 813 or less 320 495 or less Note: Air cylinders with a 180 or more. have the stroke range falling within the scope of the second
H 4 S y m b o l Initial power/ Power 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 consumption (W) Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21
Stop filling once the level of fluid reaches the H mark. 600, 1200, 2400, [AT]: Used to start auto tuning in auto tuning mode 5. Turn on the power switch to fill the piping with the fluid. 6.
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250,
Mitsubishi Electric Corporation Yaskawa Electric Corporation LJ1H202PA-K 100W to 500 LJ1H202NA-K 100W to 500 LJ1H303PA-K 200W to 500 LJ1H303NA-K 200W to 500 Standard stroke (mm) and Speed (mm/s) Model Motor type 200 300 400 500 600 700 800 900 1000 1200 1500 Capacity 100 LG1H202SC 100W to 500 LG1H202PA 100W to 500 Standard motor LG1H202NA 100W to 500 [Tamagawa Seiki Co., Ltd.]
Flow direction symbols on body Flow Rate and Effective Area Meter-out type Meter-in type ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 4, 6 8, 10 1/8 5/32 3/16 1/4 6, 8 6 Metric sizes Symbol JIS symbol 1/4 5/16 3/8 Tubing O.D. 3/16 1/4 Inch sizes 1/4 5/16 3/8 3/8 19.8 flow Flow rate l/min (ANR) {Nl/min} 1200 1300 175 295 350 600 9.1 700 75 500 Controlled (Free) Effective