SMC Corporation of America
Elite Part Number Search
Search Results "LEFS40LEB-1000"

AMF80/90/1000 N-4 Pressure outlet (IN side) N-5 Pressure outlet (OUT side) IN OUT N-2 N-1 Component Parts/Material Model AMF800/900/1000 SGP-E: SS400 SGP-E: SS400 AMF801/901 Note No. Description 1 2 Filter case Cover SGP-E: SS400 Element SS400 Replacement Parts Model AMF800 AMF801 AMF900 AMF901 AMF1000 No.

[C] [60 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C] HRS018-A-10/HRS018-W-10 (Single-phase 100/115 VAC) 2500 2500 25C Cooling capacity [W] Cooling capacity [W] 25C 2000 2000 32C 1500 1500 32C 40C 1000 1000 40C 500 500 Ambient temperature or facility water temperature Ambient temperature or facility water temperature 0 0 [50 Hz] 0 10 20 30 40 50 Circulating fluid temperature [C]

2000 3000 4000 1000 2000 4000 5000 1000 2000 3000 1000 2000 3000 3000 5000 7000 SY (Bar stock) P P P P P SY (Stacking base) P P P P P P SV P P P P P P VQ P P SQ P P P P SZ P P VQZ P P P SYJ P Features 4 SI Unit Integrated-type/For Output Series EX260 Note) RoHS Compact design Compact design for space saving Number of outputs Each 32/16 digital output type available in the series Output

PARAMETERS Setting Output item Description Setting Output item Description CCW direction CCW direction 6 Droop pulses (Note 1) ( 10V/100 pulses) 7 Droop pulses (Note 1) ( 10V/1000 pulses) 10[V] 10[V] 100[pulse] 1000[pulse] 0 0 100[pulse] 1000[pulse] -10[V] -10[V] CW direction CW direction CCW direction CCW direction 8 Droop pulses (Note 1) ( 10V/10 pulses) 9 Droop pulses (Note 1) ( 10V/10

Heavy load Standard load Midium load Light load 1 10 50 100 1 0.25 0.49 0.98 1.96 2 20 75 200 2 0.49 0.74 1.47 2.94 3 30 100 300 3 0.74 0.98 1.96 3.92 4 40 125 400 4 0.98 1.23 2.45 4.90 5 50 150 500 5 1.23 1.47 2.94 5.88 6 75 200 600 6 1.47 1.96 3.92 7.84 7 100 250 700 7 1.72 2.45 4.90 9.80 8 300 300 800 8 1.96 2.94 5.88 11.76 9 500 500 900 9 2.21 3.92 7.84 15.68 10 1000 1000 1000 10 2.45

(Example: When the value can be displayed down to 0.001 MPa for the product for 0 to 1 Mpa, the resolution is 1/1000) Display resolving power Displayed pressure value can be adjusted within the range of 5%R.D. (5% of displayed value).

For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0

For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0

No anchor bolt is included. 169 A HRSH Series Inverter Type If the product is used at altitude of 1000 m or higher, refer to Operating Environment/ Storage Environment (page 186) Item 13 For altitude of 1000 m or higher.

Unit psig/bar MPa Code No gauge port psig/bar unit V V No code MPA No code No pressure gauge (Connections: 1/4 inch NPT) -30 in.Hg to 30 psig -30 in.Hg to 100 psig 0 to 200 psig 0 to 1000 psig 0 to 4000 psig 0 2) Pressure gauge unit MPa or psig/bar selectable. However under Japanese regulation, only MPa is available in Japan.

Products Symbol Specifications -XA -XC14 Change of rod end shape Minimum operating pressure (MPa) Head: 0.15 Rod: 0.2 Change of trunnion bracket mounting position DWithout auto switch: 10 to 80C With auto switch: 10 to 60C Ambient and fluid temperature Piston speed 8 to 300 mm/s Cushion Cushion seal type Rod Sizes Stroke length tolerance to 100 st , 101 to 250 st , 251 to 630 st , 631 to 1000

Standard Stroke Bore size (mm) Standard stroke (mm) 40 50 63 80 100 25 to 800 25 to 800 25 to 800 25 to 800 25 to 1000 Theoretical Output OUT IN Unit: N Bore size (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) 10 7 3.5 OUT 1256 12560 8792 4396 40 22 IN 876 8760 6132 3066 OUT 1963 19630 13741 6871 50 28 IN 1347 13470 4715 9429 OUT 3117 31170 21819 10910 63

Besides, the overall length is longer than the cylinder with air cushion as follows, because the bumpers are attached to the both sides of the piston: 32, 40: +6 mm, 50, 63: +8 mm, 80, 100: +10 mm 148 70 190 72.5 Up to 1000 148 80 193 82.5 Up to 1000 102.5 174 100 230 Up to 1000 122 178 120 234 Up to 1000 6-7-8 9 Series MB1 Square Tube Type Air Cylinder: Standard Type Double Acting, Single

Facility water temp. 25 1500 Cooling capacity[W] 1500 25 Cooling capacity[W] 32 32 35 35 1000 1000 500 500 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T1 is selected.

When the upper limit of the scale is set to 5000, and the lower limit of the scale is set to 1000, the result will be as follows. 1000 1 V is input 2000 2 V is input 3000 3 V is input 4000 4 V is input 5000 5 V is input 3. The resolution from 1 to 5 V is 1/1000 based on the calculation (5 V 1 V) / (5000 1000) = 1/1000.

1500 0.1 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) ML2B/M1 (Pitch moment) ML2B/M2 (Roll moment) ML2B/M3 (Yaw moment) 30 40 20 20 5 4 3 10 10 5 4 3 ML2B40 ML2B40 2 5 4 3 Moment (Nm) Moment (Nm) Moment (Nm) 2 ML2B32 ML2B32 1 ML2B40 ML2B40 ML2B40 ML2B40 2 1 ML2B25

1500 0 200 400 600 800 0 500 1000 1500 Flow rate L/min(ANR) Flow rate L/min(ANR) Flow rate L/min(ANR) AC40-A Rc 1/2 AC40-06-A Rc 3/4 0.6 0.6 Outlet pressure MPa Outlet pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 1000 2000 3000 0 1000 2000 3000 4000 Flow rate L/min(ANR) Flow rate L/min(ANR) Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7 MPa,

40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

E D LY 4-LD LH MM Width across flats KA 18 N N S + Stroke LX Y X Y X LS + Stroke ZZ + Stroke LT B C (mm) AL Bore size Stroke range Symbol B B1 C D E GA GB H H1 J K KA MM N P LD A LS LH LT LX LY S X Y ZZ 6 40 3.2 1/4 42 Up to 1000 14 27 30 27 60 70 22 44 9 16 32 27 33 15 51 8 M8 x 1.25 13 102 193 40 156 M14 x 1.5 7 45 3.2 3/8 50 Up to 1000 18 30 35 32 70 80 27 52 9 20 40 27 35 17 58 11 M8

0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.