SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25S2B-500-S2"

How to Order NC D A1 B 500 04 00 XB5 Built in magnet Bore size Option Nil 500 5" None Nil No option D Auto switch capable (magnetic option) 600 6" XB5 Oversized rod 800 8" XB6 High temperature Mounting style XB7 Low temperature XC6 Stainless steel piston rod B Basic style MX0 Standard stroke Inches BA Tie rod extended both ends MX1 Notes: BB Tie rod extended head end MX2 1.

Operating Conditions Mounting Orientation Cylinder MY2H40G-500 Average operating speed a 300 mm/s Mounting orientation Wall mounting 1. Horizontal mounting 2. Wall mounting z y P. 8-13-5 Wb: MGGLB25-200 (4.35 kg) x y x z Wa: Connection plate t =10 (880 g) MY2H40G-500 3. Ceiling mounting P. 8-13-5 4.

Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200

Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 50 63 80 100 125 140 160 180 200 250 300 Average speed (mm/s) Series 1000 1100 Perpendicular, upward actuation 900 Horizontal actuation 800 700 600 500 400 300 200 100 VK VQ7-8-FG-S-A03 VQ7-8-FG-S-RA03 VZ VF 0 1000 1100 VFR 900 800 700 600 500 400 300 200

Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.

P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).

Position data Speed Dwell Auxiliary Model adaptive control 1 1000 1000 80 80 0 0 Speed control 2 2000 2000 100 100 0 0 3 4000 2000 70 60 500 1 4 500 2000 60 70 1000 1 5 2000 80 80 0 0 1000 6 2000 1000 80 80 0 0 Position 7 1000 1000 80 80 0 0 control LEC-MR-J3BAT 8 1000 1000 100 100 0 0 MR-J3BAT 1000 1000 100 100 0 0 (Note 3) CN4 255 2000 2000 80 80 0 0 Position Optional battery (for absolute

m/s2 Impact resistance Insulation resistance 50 M or more at 500 VDC Mega (between lead wire and case) 1500 VAC for 1 minute (between lead wire and case) 1) 1000 VAC for 1 minute (between lead wire and case) Withstand voltage Ambient temperature 10 to 60C Enclosure IEC60529 standard IP67, JIS C 0920 waterproof construction Standards Conforming to CE standards 1) For connector type D-A73C

After improvement Before improvement Conventional coil tube model Filter regulator Conventional coupler model S coupler 1 2 1 2 Coil tube L L VMG Air gun Nozzle 2.5 Nozzle 3 S2 S0 to S1 S2 S0 to S1 Effective area ratio 3.04 : 1 Effective area ratio 0.69 : 1 Before improvement After improvement Coupler S coupler Conventional model Piping Equipment TCU1065-1-20-X6 Conventional coil tube model

(I.D. 5, equivalent length 5 m) Air gun VMG (Nozzle size 2.5) Conventional model (Nozzle size 3) Coupler, Piping (S0) 13.45 mm2 5.1 mm2 Effective area Air gun (S1) 30 mm2 6 mm2 Nozzle (S2) 4.4 mm2 6.3 mm2 0.69 : 1 3.04 : 1 Effective area ratio (S0 to S1: S2) Impact pressure 0.011 MPa (at a distance of 100 mm) 0.011 MPa (at a distance of 100 mm) Regulator pressure 0.4 MPa 0.5 MPa Pressure

550 10 to 300 Parallel Stroke 701 to 800 20 to 550 12 to 330 6 to 180 24 to 750 16 to 500 8 to 250 30 to 750 20 to 550 10 to 300 range 801 to 900 24 to 610 16 to 410 8 to 200 30 to 750 20 to 550 10 to 300 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 750 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to 190 Max acceleration/deceleration

Wall mounting Cylinder MY1MW40-500 z Average operating speed a 200 mm/s Mounting orientation Horizontal mounting y Wd: Workpiece (500 g) x y Wc: MHL2-16D1(795 g) x z Wa: Connection plate t = 10 (880 g) x 3. Ceiling mounting 4. Vertical mounting MY1MW40-500 z y x y z Wb: MGGLB25-200 (4.35 kg) For actual examples of calculation for each orientation, refer to the pages above. 2.

speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.

Series SYJ3000/5000/7000 and Series SYJ300/500/700 can be mounted on the same manifold. How to mount on the same manifold is shown on the following pages. PDisconnection To remove the socket from the connector, pull out lead wire while depressing the hook of the socket with a fine screw driver (or similar). If the socket is to be re-used, reposition the hook again.

(Error number 5) Vs : Power supply 24 VDC A : Input signal 4 to 20 mA DC 0 to 20 mA DC Vs : Power supply 24 VDC Vin : Input signal 0 to 5 VDC 0 to 10 VDC 4 points preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24 VDC (Negative common) One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: S3 (200W Output, Incremental Encoder), Lead: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 500mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: S (Standard Cable), Cable Length:

Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: S3 (200W Output, Incremental Encoder), Lead: B (LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm), Stroke: 500mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: S (Standard Cable), Cable Length: 2

Size: 63, Motor Type: S7 [AC Servo Motor (Absolute Encoder) 200W], Lead, mm: Size 40: 8mm, Size 63: 10mm, Stroke: 500mm, Motor Option: None, Cable Type: Standard, Cable Length: 2m, Driver Type: -, I/O Connector: -

Accuracy: H (High Precision Type), Size: 40, Motor Type: S2 (100W Output, Incremental Encoder), Lead, mm: A (Size 40: 16mm, Size 63: 20mm, Size 100: 25mm), Stroke: 500mm, Motor Option: None, Cover: w/o Cover, Cable Type: S (Standard), Cable Length: 2m

Series: Ball Screw Drive, Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor Type: 200W Output, Incremental Encoder, Lead: LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm, Stroke: 500mm, Motor Option: w/o Option, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Cable Type: Standard Cable, Cable Length: 2m, Driver Type: -,