20 18 13 26 10 8 16 10 12 12 8 10 10 41 5 8 31 5 25 to 300 15.5 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 5.5 25 to 400 19.5 32 24 22 38 16 14 19 11 13 13 8 10 10 53 8 9 40 7.5 25 to 500 21 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 7.5 25 to 500 21 (mm) Bore size (mm) LH LS LT LX LZ MM NA NB P S T V W X Y ZZ LD 20 25 121 5.5 40 55 M8 x 1.25 17 15 1/8 81 9.5 4.5 6.5 20 9 151
0.2MPa 0.3MPa 0.1MPa 0.1MPa 0.3MPa 0.4MPa 8 8 Discharge time [s] 0.4MPa 0.5MPa 0.5MPa 0.2MPa Discharge time [s] s s 6 6 4 4 2 2 0 0 0 500 1000 1500 2000 0 300 600 900 1200 1500 mm mm Installation distance [mm] Installation distance [mm] 6-2.
Find the value of Wmax when Va = 300 mm/s from Graph (1). L2 L1 xStatic moment Examine M2. Since M1 & M3 are not generated, investigation is unnecessary. M2 = W L1 = 10 0.05 = 0.5 [Nm] 2 = M2/M2 max = 0.5/16 = 0.031 W = 1 [kg] = 10 [N] W M Find the value M2 max when Va = 300 mm/s from Graph (3).
] Moment M2 [Nm] CY1S25-Z CY1S10-Z CY1S20-Z CY1S6-Z 10 1 0.5 5 200 300 100 400 100 400 300 200 Piston speed [mm/s] Piston speed [mm/s] 1492 Model Selection CY1S Series Consideration of guide load factor e 3 Work load mass and allowable moment varies depending on the load mounting method, stroke, cylinder mounting orientation and piston speed.
mm/s Piston speed mm/s Piston speed mm/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass kg Load mass kg 4 4 4 4 3 3 3 3 CY1F15 CY1F10 CY1F10 CY1F10 2 2 2 2 CY1F10 1 1 1 1 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 Piston speed mm
M2 Find the value of M2 max at 300 mm/s in Graph (2). m x g CY3B CY3R CY1S M1E = 1/3 x FE x L1 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L1 = 0.05 x 300 x 0.5 x 0.05 = 0.375 [Nm] 3A = M1E/M1E max = 0.375/1.07 = 0.350 3. Dynamic moment Investigate M1E. Find the collision speed . =1.4 x a =1.4 x 300 =420 [mm/s] L1 M1 CY1L a CY1H Find the value of ME1 max at 420 mm/s in Graph (1).
300 100 50 0.5 500 300 100 50 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s 8-16-7 7 Series CY1F Vertical Actuation 1.
rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.
0.1 0.06 1 0.1 0.02 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Technical Data Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s 1187 Mechanically Jointed Rodless Cylinder Basic Type 25, 32, 40 MY1B Series RoHS How to Order M9BW 25 Z 300 MY1B Basic type Made to Order Refer to page 1189 for details
The initial exhaust rate is adjusted by turning the adjustment nut counterclockwise. x Opening of the initial exhaust valve (valve S) When the pilot pressure is applied to the pilot port S, the valve S is removed from the valve S seal assembly, and the valve opens the adjusted amount.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) Combination of K, L and M are not possible because an auto drain can only be attached to a single option. Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. The option S cannot be chosen.
500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Technical Data 1207 Mechanically Jointed Rodless Cylinder Linear Guide Type MY1H Series 25, 32, 40 RoHS How to Order M9BW 25 300 MY1H Z Linear guide type Linear guide type Made to Order Refer to page 1209 for details
Maximum acceleration: 2000mm/s Positioning time (sec.) Positioning distance (mm) 1000 500 100 10 1 10 100.4 50.4 10.4 1.4 0.5 100 10.4 5.4 1.4 0.5 0.4 Speed (mm/s) 150 7.1 3.8 1.1 0.5 0.4 300 3.8 2.2 0.8 0.5 0.4 Values will vary slightly depending on the operating conditions.
32 40 50 63 80 100 NA P S TA TB ZZ 11 11 77 1/8 24 114 Up to 200 11 11 77 1/8 29 119 Up to 300 11 11 79 1/8 35.5 121 Up to 300 12 12 87 1/8 44 139 Up to 300 13 13 102 1/4 55 162 Up to 300 13 13 102 1/4 69 162 Up to 300 122 3/8 80 196 Up to 300 122 1/2 100 196 Up to 300 13 Smooth Cylinder Series CA2Y 40, 50, 63, 80, 100 Specifications and auto switch information not provided below are
Stations J kit (Flat ribbon cable) G kit (Flat ribbon cable with terminal block) P kit (Flat ribbon cable) F kit (D-sub connector) Cylinder port Kit U S A U S P 26P 20P J U S U S F 15P U S P 16P U S B P 20P U S C P A 10P F 25P G Type Negative common specifications Max. points 24 14 24 18 14 8 16 16 Electrical entry Cable length M kit (Circular connector) T kit (Terminal block box) S kit (
CCT160-l 3/8 3/4 9.5 11 0 30 86 3 28 45 53 88 86 64 88 104 CC 1/2 7 13 2 1 32 120 5 33 65 61 123 116 92 125 139 11/4 3/4 7 20 2 46 185 0 29 93 60 183 180 144 185 202.5 L dimension 600 700 800 Effective oil level stroke (mm) 50 100 200 300 400 500 CCT63-l 228.5 278.5 378.5 503.5 603.5 728.5 s s s CCT100-l 286 386 511 611 736 836 s s s CCT160-l 399 524 624 749 849 949 1049 s s * Hexagon socket
Impact speed (mm/s) L-unit 1000 1000 Air cushion 500 400 300 500 400 300 L-unit Air cushion 200 200 Caution 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 1.
IDG75M IDG100M IDG3HM IDG5HM IDG10HM IDG20HM IDG30HM IDG50HM IDG60HM IDG75HM IDG100HM 25 50 100 200 300 500 600 750 1000 25 50 100 200 300 500 600 750 1000 IDG30LM IDG50LM IDG60LM IDG75LM IDG100LM 75 110 170 240 300 IDG60SM IDG75SM IDG100SM 50 100 150 Type V A regulator combined with the type M IDG3V IDG5V IDG10V IDG20V IDG30V IDG50V IDG60V IDG75V IDG100V IDG3HV IDG5HV IDG10HV IDG20HV IDG30HV