A A1 E1 L1 MM RR1 U1 ND NX NZ L 34 41 42 56 71 79 8.5 16 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 34 41 42 56 71 79 8.5 10.5 14 18 21 21 16 20 22 28 38 44 25 30 30 40 50 55 M8 x 1.25 10.3 12.8 12 16 21 24 11.5 14 14 20 27 31 8 10 10 14 18 22 8 10 18 22 28 32 8 10 10 14 18 22 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10
Brown 1 (41.5) OUT1 4 Black Load White OUT2 2 + Load 3 Blue 12 to 24VDC 73 42 PF2W7--67(-M) 4 Connector pin numbers 4 3 2-3.4 43 Flow direction L Dimension 100 106 Model PF2W704 PF2W720 2 1 Pin description DC(+) OUT2 DC() OUT1 Pin no. 1 2 3 4 PF2W740 120 60 1.6 17 67 6 FLOW SWITCH U P 60 50 34 55 34 S E T OUT1 OUT2 DOWN FOR WATER 34 2-Port size 4-4.5 40 50 (41.5) 73 34 Flow direction 16
34 34 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M27 x 2 10 11 14 20 20 27 16 19 24 34 34 42 10 10 14 22 22 25 10 10 14 22 22 25 14 14 20 30 30 32 14 14 20 30 30 32 28 28 40 60 60 64 50 12.5 CS1 64 16.5 80 23.5 C76 80 23.5 119 28.5 Note) For a double clevis, a pin (cotter pin) and a flat washer are equipped as standard.
A A1 E1 L1 NZ 16 16 20 22 28 38 44 34 41 42 56 71 79 25 30 30 40 50 55 20 25 32, 40 50, 63 80 100 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10 Y-G02 Y-G03 Y-G04 Y-G05 Y-G08 Y-G10 34 41 42 56 71 79 25 30 30 40 50 55 IY-G02 16 20 IY-G03 20 22 IY-G04 36 28 IY-G05 44 38 IY-G08 56 44 IY-G10 Knuckle pin and snap ring are included. 64 Knuckle Pin (Common with double clevis pin
7.1 Failsafe errors.34 7.2 Alarms.34 7.3 Errors.34 7.4 Warnings .35 7.5 Notifications.36 8 TROUBLE SHOOTING.36 9 ND9000 WITH LIMIT SWITCHES.37 9.1 Introduction .37 9.2 Installation on a valve controller .40 9.3 Electrical connections.41 9.4 Adjustment.41 9.5 Removal of the limit switches for accessing the valve controller.41 9.6 Circuit diagrams.41 9.7 Maintenance .41 10 TOOLS.41 11 ORDERING
(48) 31 (45) 32.5 (46.5) 80 59 48.5 50 47 34 (48) 31 (45) 32.5 (46.5) 100 69.5 48.5 50 47 Numbers inside ( ) are for long strokes. 33 Guide Cylinder Series MGG Proper Auto Switch Mounting Position (Stroke End)/End Lock Type: With Head Side Locking A 8.5 B Approx.
30.5 13 9 10 36 32 33 32 18.5 13.5 29 24.5 10.5 21.5 9 20 16 13 12 27 23 24 40 22 17 33.5 28.5 14 25.5 12.5 24 19.5 16.5 15.5 31 27 28 50 25 20 34 29 17 26 15.5 24.5 22.5 19.5 18.5 31.5 27.5 28.5 63 Note) When setting an auto switch, confirm the operation and adjust its mounting position.
O L S ENERGIZED OPEN TYPE ENERGIZED CLOSED TYPE T E C H N I C A L SPECIFICATIONS E N E R G I Z E D O P E N T Y P E S E R I E S VXD 1MPa = 145PSI Minimum Connection Orifice Flow Rate Model Maximum Operating Pressure Maximum Operating mm Cv Effective Differential MPa System Pressure Water Area Pressure Oil Air Differential MPa AC DC (mm2) MPa AC DC AC DC 0.02 0.7 0.5 1/4 VXD2130-02 10 1.9 34
R +0.058 0 0.2 0.4 8 8 0.2 0.4 10 0.3 0.5 18 I-G02 I-G03 I-G04 Y-G02 Y-G03 Y-G04 +0.058 0 8 +0.4 +0.2 8 16 20 22 16 20 22 20 25, 32 40 34 41 42 8.5 10.5 14 25 30 30 M8 M10 X .25 M14 X 1.5 10.3 12.8 12 11.5 14 14 34 41 42 8.5 25 30 30 M8 10.3 12.8 12 11.5 14 14 16 20 36 IY-G02 IY-G03 IY-G04 20 21 +0.058 0 10 +0.058 0 10 +0.4 +0.2 10 +0.5 +0.3 18 10.5 16 25, 32 40 M10 X 1.25 M14 X 1.5 25.6
(A) (A) No-fuse breaker D 40 Circuit breaker 60 A C B Power connection E Power cable outlet (17) 35 Grommet with membrane (mm) Dimensions E D C B A Model 32 IDF4E, 6E, 8E, 11E IDF15E IDU3E, 4E, 6E IDU8E IDU11E IDU15E 97 230 34 15 102 258 82 43 With circuit breaker case 97 15 34 32 230 37 A Dimensions (mm) 42 100 75 Model 69 258 43 84 IDF120D IDF150D IDF190D IDF240D IDF370B 94 IDF22E to
Fluid and Ambient Temperature Valve Leakage Rate Internal Leakage Fluid temperature F (C) Ambient temperature F (C) Seal material Leakage rate Note) 34 to 140 (1 to 60) Note) FKM 106 Pam3/sec or less 4 to 140 (20 to 60) Note) With no freezing External Leakage Seal material Leakage rate Note) 106 Pam3/sec or less FKM Note) Leakage (106 Pam3/sec) is the value at differential pressure 15 psi
ON OFF 3 34 3 (3) (10ms) ON OFF ()ON MBR (MBR) OFF . ON OFF (4)OFF (10ms) (1)1560ms ON OFF 2 (2)ON (MBR) MBR OFF ON OFF 1. 2. ON OFF 3 35 3 (5) () (10ms) (1)15ms ON OFF (2)ON (MBR) MBR OFF ON OFF 1. 2. ON OFF (6)Ready-off (10ms) ON OFF ()ON MBR (MBR) OFF Ready-off () ON () OFF .
Ground plate Ground plate 3-34 3 Wiring and Connection Connect the noise filter ground wire directly to the ground plate. Do not connect the noise filter ground wire to other ground wires.
Hs Reed switch D-A3 Solid state switches D-G39/K39 34 56 56 A A 36 49 Auto switch G 1/2 (compatible cable O.D. 6.8 to 11.5) Approx.
A B C D G E(g6) F(h9) K S1 T N R L S2 U M V W H X Y Model 4 -0.004 -0.012 -0.004 -0.012 -0.004 -0.012 -0.005 -0.014 0 -0.036 0 -0.043 0 -0.043 0 -0.043 29 9 3.5 17 29 15.5 10.5 10.5 M5 X 0.8 M3 X 0.5 22 0.5 3 14 25 1 9 31 41 18.5 CDRBUW10-lS 34 10 3.5 21 29 15.5 10.5 10.5 M5 X 0.8 M3 X 0.5 25 0.5 3 18 29 1.5 5 12 36 48 18.5 CDRBUW15-lS 34.5 17 11 42 10 4.5 26 30 11.5 M5 X 0.8 M4 X 0.7 0.5
Refer to the dimensions on page 562 for the mounting dimensions. (35) (25) 5.5 1.25 L Dimension [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448
Red Hard steel roller Actuator type Basic 00 Color of push button selector Port size Black Roller lever 01 01 1 8 Rc NPT G Green One way roller lever 02 1 8 N01 F01 Y Yellow Straight plunger 05 Roller plunger 06 1 8 Cross roller plunger 07 Toggle lever 08 Number of ports Push button (Mushroom) 30 3 3 port Push button (Extended) 32 Push button (Flush) Note 1) 33 Twist selector (2 position) 34
Form w 1 Material e Vacuum inlet r A Width across flats 7 Mounting Bracket Assembly Flat, Ball Joint Type Thin Flat Type with Ribs Bellows Type Connection thread M5 x 0.8 10 42 26 2.5 B 13 44.5 28.5 16 46 30 20 51.5 33.5 3.5 25 52 34 32 57 39 10 B5 M5 x 0.8 5 C2 42 26 2.5 N S U F GN GS 13 44.5 28.5 16 46 30 20 51.5 33.5 3.5 25 52 34 32 57 39 40 62 44 6 50 66 48 20 N4 N6 U4 U6 Construction
Display the required function number and press the SET button. -29No.PF-OMV0006-B Default settings Item Default setting Page Without units selection function [ Unit] Display unit setting [ L] L/min, oC Page 34 [AC_E] Units selection for accumulated flow value [ 0] Accumulated flow units 100 Page 34 [ NorP] Switching setting of switch output NPN/PNP [ PnP] PNP output Page 34 [ diAG] Diagnostic