Size Lead Order no. 16 Wear ring holder Stainless steel Stroke 101 mm or more 20 25 LE-D-2-2 20 63 A/B/C LE-D-2-5 17 Wear ring POM Stroke 101 mm or more 32 LE-D-2-4 L LE-D-2-6 18 Screw shaft pulley Aluminum alloy 740 Electric Actuator/Rod Type LEY Series AC Servo Motor 25, 32, 63 Size Dimensions: Motor Top/Parallel X Encoder Z-phase detecting position W ZZ F1 Rod operating range Note 1) (
FL1 (A) F1 K (mm) (H) A F1 H FL1 16.5 K 3 Bore size Stroke range 24 32 40 51 21 Up to 1000 22 18 54.5 3 22.5 Up to 1000 : Same as the standard model. 1896
Allowable Driving Force Table (Fn) (n=1,2,3) F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 1466 for the maximum load weight when loaded directly on the body and connection bracket.) F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for the (Fn) of data K A .
(KB) KA 2 x 2 x OB counterbore depth RB M Z X B + Stroke L EB A + Stroke EA E Axial piping Bore size (mm) F1 32 40 50 63 30 34.5 43.5 51 Bore size (mm) Stroke range (mm) A B E EA EB F HA HB J KA KB L M N OA 32 40 50 63 5 +0.2 0 5 +0.2 0 6 +0.2 0 6 +0.2 0 28 0.2 33 Note 1) 40 Note 1) 45 43 34.4 6.5 M5 x 0.8 22.5 19.8 7 34 5.4 M6 x 1 5 to 100 33 0.2 39.5 52 50 41.4 6.5 M5 x 0.8 26 23.3 7 40
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
Load (kg) Note: 1 Nm = 0.7375 ftlb 1 kg = 2.2046 lb 1 in = 25.4 mm W1 W W m Moment (Nm) M = F x L M = F x L M = F x L F3 F2 F1 L2 L1 L3
Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F1 = x A1 x P (1) F2 = x A2 x P (2) A1 = D2 (3) 4 A2 = (D2 d2) (4) 4 F1 = Cylinder force generated on the extending side (N) F2 = Cylinder force generated on the retracting side (N) = Load rate A1 = Piston area on the extending side (mm2) A2 = Piston
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2
-X 20m2 m3 Data Moment (Nm) M1 = F1 x L1 F1 F2 M3 = F3 x L3 F3 M2 = F2 x L2 L1 L2 L3 Maximum Load Weight Select the load from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes be exceeded even within the operating limits shown in the graphs. Therefore, also check the allowable moment for the selected conditions.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
Electro-Pneumatic Regulator SMC REGULATOR ITV2000 Electronic Vacuum Regulator Series ITV Series Model Set pressure range Port size Page Series ITV2000 Controls air pressure steplessly in proportion to an electric signal.
ITV Electro-pneumatic Regulator Electronic Vacuum Regulator ITV103 0.005 to 0.5 MPa IC 1/8, 1/4 14-8-14 VBA ITV105 0.005 to 0.9 MPa VE VY1 Series ITV2000 ITV201 0.005 to 0.1 MPa Controls air pressure steplessly in proportion to an electric signal.
ITV Dimensions IC ARM10-06 08 For dimensions and accessories of One-touch fittings, please refer to page 523.
control pressure measurement value [high byte] UnitkPa 23 ITV control pressure measurement value [low byte] 24 ITV diagnostic data [high byte] 25 ITV diagnostic data [low byte] Air Management Hub internal error 2 Air Management Hub internal error 1 Port 3 short circuit VP short circuit 26 Reserved 27 ITV-PQI 28 Port 4 PQI Isolation input signal (Port 3) Standby input signal X2 (Port 4 input
L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ITV NO.
L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ITV NO.
1 SRP u q SRF SMC ITV IC A o ITVH ITVX PVQ Component Parts Replacement Parts VY1 Part no. Material Material Note Description No. Description No.
The product number determines if only SI units are valid, or all units are valid ITV*050-IL*0-*-K-X399: Valid for all units ITV*050-IL*0-*-M-X399: Valid for SI units only Bit Bit 3 Value ITV*050-IL*N-*-K-X399 Bit ITV*050-IL*N-*-M-X399 Bit Value Unit 0 MPa 1 kPa 2 bar 3 PSI 4 kgf/cm2 Value Unit 0 MPa 1 kPa indicates the initial shipping value.