.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Load weight (kg) Dm1 -X 20m2 m3 Moment (Nm) Data M3=F3 x L3 F3 F2 M1=F1 x L1 F1 M2=F2 x L2 L2 L1 L3
Rc 1/8 Body side VZA414-1P-01 VZA414-1P-02 VZA414-2P-01 VZA414-2P-02 VZA424-1P-01 VZA424-1P-02 VZA424-2P-01 VZA424-2P-02 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Sub-plate side M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Body side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O. Sub-plate side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O.
7 POM o POM Valve seat (B) 5-6-36 5 Port Mechanical Valve Metal Seal Series VZM400 Series VZM400 Basic VZM450-01-00 JIS Symbol Accessory mounting hole (Pilot exhaust port) SA VA SA VA 0.5 MPa supply VM 1.0 mm P.T. 16 N F.O.F. VR 2.0 mm O.T. 2-3.5 mounting hole 3.0 mm T.T.
(synchronized with SA) Red ON Component failure inside the AMS Hub. Orange flashing Internal communication error in wireless adapter. OFF Standalone mode. SA Green ON Wireless mode. Red flashing Pairing mode. (synchronized with ST) OFF Power not supplied. PWR Green flashing Power supply voltage is abnormal. Green ON Power supply voltage is in the specification.
-04-12 AS1301FG-M5-23 AS2301FG-01-23 AS1301FG-M5-04 AS2301FG-01-04 -02-04 AS1301FG-M5-06 AS2301FG-01-06 -02-06 AS3301FG-02-06 -03-06 AS2301FG-01-08 -02-08 AS3301FG-02-08 -03-08 AS1211FG-M5-23 AS2211FG-01-23 AS1211FG-M5-04 AS2211FG-01-04 -02-04 AS1211FG-M5-06 AS2211FG-01-06 -02-06 AS3211FG-02-06 -03-06 AS2211FG-01-08 -02-08 AS3211FG-02-08 -03-08 AS2211FG-01-10 -02-10 AS3211FG-02-10 -03-10
BA 32 BA 04 BA 05 BA 06 BA 08 BA 10 BA 01 BA 02 BM1 01 BM1 02 BM1 32 BM1 04 BM1 05 BM1 06
Piping: Rc1/4, Output: 43 [NPN Open Collector 1 Output (Pin No.:4)+PNP Open Collector 1 Output (Pin no.:2)], Display Unit: With Unit Display Switching Function, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket
Piping: Rc1/4, Output: 67 [PNP Open Collector 2 Outputs (Pin no.: 2,4)], Display Unit: With Unit Display Switching Function, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)