Long Stroke (101 to 200 mm) -X10 4 Refer to the table of number of the auto switches mounted below.
A span adjuster and zero adjuster are provided for the adjustment of the feed back spring.Provides accurate and stable positioning of air cylinders, Compact design, Zero adjusting screw and feedback spring material available in steel or stainless steel, Available in standard, low or high temp, IP200 1/4 INCHPT VERSION, INSTRUMENTATION, IP200 POSITIONER, DA, IP200 1/4 INCHPT VERSION,
Rubber bumper (Magnet type) Standard Strokes Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 50, 100, 150, 200 Made to Order Made to Order: Individual Specifications (For details, refer to pages 1507 and 1508.) 300 6 50, 100, 150, 200, 250, 300 500 Symbol Specifications 10 -X116 -X168 -X210 -X322 -X324 -X431 -X2423 Air-hydro 50, 100, 150, 200, 250, 300, 350, 400, 450
M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63
Example) In the case of MVGQM20-35 st, a 5 mm width spacer is installed in the MVGQM20-40 st body; thus, the full length dimension are the same as the 40 st. 220 V [230 V] 1.30 (With indicator light: 1.34) [1.42 (With indicator light: 1.46)] Surge voltage suppressor Diode (Non-polar type: Varistor) Indicator light LED Conforming to IEC60529 100 VAC and 115 VAC, 200 VAC and 230 VAC are common
The IP200 cylinder positioner provides accurate and stable positioning of air cylinders.??The compact design allows easy installation and maintenance.?
CX CZ L RR 25 15 to 100 14 20 18 36 14.5 10 105 to 200 32 20 to 100 14 22 18 36 18.5 10 105 to 200 63 50 to 200 22 30 22 44 37.4 14 205 to 500 505 to 800 Material: Cast iron (Coating) * The A and CL measurements are when the unit is in the Z-phase first detecting position.
(inch): 0 to 0.04 inch (1.0 mm) 10.01 to 40 st (inch): 0 to 0.06 inch (1.4 mm) 40.01 st (inch): 0 to 0.07 inch (1.8 mm) Stroke length tolerance Made to Order Made to Order (Refer to pages 9 for details.)
For MGQM20-21 st, MGQM20-30 st is provided with a 5 mm + 4 mm 9 mm width spacer. 2. For MGQM50-40 st, MGQM50-50 st is provided with a 10 mm width spacer.
200 CLJ2 500 180 Load mass: m (kg) Load mass: m (kg) 180 1000 160 700 800 900 400 CLM2 140 160 600 125 300 CLG1 500 140 400 CL1 125 300 200 200 MLGC CNG 100 500 400 300 200 100 100 500 400 300 200 100 MNB Maximum speed: V (mm/s) Maximum speed: V (mm/s) CNA Graph 6 Graph 3 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa CNS 4000 2000 250 3000 CLS 250 200 2000 180 1000 CLQ 700 800 900 160 200 140
With Rod Boot Data l Z Symbol h B3 e f Stroke Bore size (mm) 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 20 36 17 30 68 81 93 106 131 156 181 12.5 25 37.5 50 75 100 125 160 173 185 198 223 248 273 25 36 17 32 72 85 97
T1 = V/a1 = 200/3000 = 0.067 [s], T3 = V/a2 = 200/3000 = 0.067 [s] 40 0.5 200 (0.067 + 0.067) 200 T2 = = = 0.133 [s] L 0.5 V (T1 + T3) V T4 = 0.2 [s] Therefore, the cycle time can be obtained as follows.
, 250, 320, 400, 500 1000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1900 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 125 2000 Made to Order (For
Setting over 200 rev will be clamped with 200 rev. 0 0 to [rev] 1000 (Note) Note. Setting can be changed in [Pr. PC06].
For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
At the setting of STA 20, STB 5000 and STC 200, the actual arc part times are as follows. (Example) Limited to 100[ms] since During acceleration: 100[ms] 20 20 100[ms] 200[ms]. 200[ms] as set since During deceleration: 200[ms] 20 5000 400[ms] 200[ms].
, 250, 320, 400, 500 2000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 Intermediate strokes are available
Basic Compact LEHZ25 LEHZ25L 250 250 200 200 Overhang H [mm] Overhang H [mm] 70%, 40% 150 150 40% Pushing force 100% Pushing force 100% 100 100 70% 50 50 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Gripping point L [mm] Gripping point L [mm] LEHZ32 250 200 Overhang H [mm] 150 40% 100 Pushing force 100% 70% 50 0 0 50 100 150 200 250 Gripping point L [mm] LEHZ40 250 200 Overhang H [mm] 150
C3: 3.2 (SMC) C4: 4 (SMC) C6: 6 (SMC) N1: 1/8" (SMC) N3: 5/32" (SMC) N7: 1/4" (SMC) L: DIN Rail Overall Length n: Stations L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L1 L2 L3 L4 L5 135.5 148 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 125 137.5 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 102.2 112.7
Bore size Series MB, CA2 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It