Never use in the presence of explosive gases. The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount switches in locations where there is no vibration greater than 98 m/s2, or no impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
(The test was performed with the actuator in the initial state.) Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. The test was performed in both an axial direction and a perpendicular direction to the lead screw.
If mounted in a wrong direction, the equipment to be connected may result in malfunction. Refer to pages 1413 to 1417 for external dimensions in mounting.
If mounted in a wrong direction, the equipment to be connected may result in malfunction. Refer to pages 4-5-4 to 4-5-9 for external dimensions in mounting.
VT Change of electrical entry (Orientation) After separating terminal block and housing, the cord entry direction can be changed by attaching the housing in the desired direction (4 directions in 90 increments). In the case of indicator light, avoid damaging the light with lead wire.
Bore Piston Area Forces (lbs); Push Stroke (in) (in) Operating medium Pressure (PSI) 50 60 80 100 200 250 1.5 1.767 88 106 141 177 353 442 HOW TO USE THIS TABLE 1 Locate column with desired operating pressure. 2 Move down that column and locate the thrust value which is equal (or the next larger to the force to be delivered by the cylinder.) 3 On that same line, locate in the first (left)
It can operate in temperatures between 10 to 60C if there is no risk of the moisture in the air freezing.
Brown [Red] When two switches are connected in series, a load may malfunction because the load voltage will decline when in the ON state. The indicator lights will light up if both of the switches are in the ON state.
Specifications The conventional pneumatic pressure line AM Series + AMD Series have been integrated to achieve a reduction in installation space, savings in piping installation labor, and reduced costs.
It is already built-in to the rectifier circuit. For R and U, DC voltage is only available. Power saving circuit is only available in the "Z" type.
Product with Nuts How to order a flow sensor, PF2D5S series, etc. nut type fittings without a nut (including insert bushings) in one place.
SUP srG srG SUP Incresing Signal Conatanl signal Decreasing Signal 2 CYLINDER POSITIONING ASSEMBLY HOW TO ORDER HOW TO ORDER The part number key below will assist in ordering. substitute the required bofe, stroke, etc., in the key example to conslruct the number ol the required actuator.
Mounting of Auto Switch When mounting an auto switch, insert it into the cylinder's switch groove from the direction shown in the figure below. After setting it in the mounting position, use a flat head watchmakers screwdriver to secure it with the mounting screw which is included.
Also suited for use in areas in which water splashes, such as food processing equipment or car washers. q Do not operate the cushion valve in the fully closed or fully opened state. Using it in the fully closed state will cause the cushion seal to be damaged.
When using another switch in addition, list its part number next.
It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.
Olf a lubricant is used in the system, use turbine oil type f 1 (lSO VG32). lf lubricant has been used in the system, do not cease to lubricate as the original lubricant applied during manutacturing will have been washed away.
Removes odor and gas ingredients in compressed air.
magnets Cushion In the case of cylinders with built-in magnets but no auto switches, do not indicate any auto switch type symbol.