156 180 181 205 206 230 231 255 40 Up to 200 63.5 14 49 22 18 10 6.6 40 4.5 (58.4) 56 30 30 71.4 175 200 200 228 225 253 250 278 For dimensions of pivot bracket, refer to page 309.
st 1000 st 2 900 st 1.5 800 st 700 st 1 600 st 400 st 500 st st: Stroke (mm) 0.5 100 st 200 st 300 st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM100Stroke 4 (Slide bearing type) 3.5 3 1300 st Deflection Y (mm) 2.5 1200 st 1100 st 2 1000 st 1.5 900 st 800 st 1 600 st 700 st st: Stroke (mm) 400 st 500 st 0.5 100 st 200 st 300 st 0 0 100 50 150 200 250 300
W Double rod K* Non-rotating * available for 150, 200 and 250 bores only ** use single rod designation when ordering XC11 kit Note: XC10 seal kit order 2 single rod kits *** not available with K option How To Order Tie Rods NC1A 150 11 2759 0400 How To Order Cylinder Tube Double Acting Single Rod Applicable Bore Tie Rod Size Bore 150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325
Inrush current: No breaking at the current values shown in the table for 20 ms. 3-6 3 Wiring and Connection 3.1.3 Using the DRIVER with Single-phase, 200 V Power Input LECYU2 series three-phase 200 V power input DRIVER can be used also with a single-phase 200 V power supply.
(Pending for UL Standards) 1000/1100 200/200 Watercooled refrigeration Anti-quake bracket4 Single-phase 100 VAC (50/60 Hz)/ 115 VAC (60 Hz) Single-phase 200 to 230 VAC (50/60 Hz) Concentration meter HRR012 1000/1200 400/500 (100 V type) 450/500 (200 V type) Air-cooled refrigeration With electric conductivity control function, Applicable to DI water piping HRR018 1600/1800
7 5.5 32 2 14 44 40 Up to 200 7 6.6 38 2 18 53 40 Up to 200 8 6.6 46 2 25 61 50 End boss is machined on the flange for E.
NCDMB075-0400-M9B-X169US NCDMB(075 to 200)Stroke (C)-X169US ZB + STROKE W B-DIA.
[mm] Bore size Standard stroke Max. stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
400 300 200 100 MY3A max.
0 100 200 300 400 500 600 700 0 50 100 150 200 250 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) NOTE) Contact SMC for details of ARBY7000 (New) 1.2-182 5 Port Solenoid Valve/Body ported Cassette Type Manifold Series SY3000 / 5000/7000 SV SY SY SYJ SX VK Series SY7000 VZ VF VFR VP7 VQC Series SY5000 SQ VQ VQ4 VQ5 VQZ VQD Series
Inrush current: No breaking at the current values shown in the table for 20 ms. 3-6 3 Wiring and Connection 3.1.3 Using the DRIVER with Single-phase, 200 V Power Input LECYM2 series three-phase 200 V power input DRIVER can be used also with a single-phase 200 V power supply.
The upper limit for the actual time of the arc part is as follows: At acceleration: 20 STA , At deceleration: 20 STB (Example) Settings of STA = 20, STB = 5000 and STC = 200 limit the actual arc part times as follows: 20 20 Since =100[ms]<200[ms], At acceleration: 100 [ms] the time is limited to 100[ms]. 20 5000 Since =400[ms]>200[ms], At deceleration: 200 [ms] the time is as-is.
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
HRSH150/200-A: 2 pcs. are used per unit HRS-S0214 Dust-proof filter (Upper) 1 pc. HRSH100/150/200-A: 2 pcs. are used per unit HRS-S0185 Dust-proof filter 1 pc.
With Rod Boot Data l Z Symbol h B3 e f Stroke Bore size (mm) 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 20 36 17 30 68 81 93 106 131 156 181 12.5 25 37.5 50 75 100 125 160 173 185 198 223 248 273 25 36 17 32 72 85 97
mm/s or less L = 100 mm, V = 200 mm/s or less 10 10 Load mass m [kg] Load mass m [kg] 1 1 0.3 0.3 10 30 31 101 200 100 10 30 31 100 101 200 Stroke [mm] Stroke [mm] MGPKL32 L = 50 mm, V = 200 mm/s or less L = 100 mm, V = 200 mm/s or less 50 50 Load mass m [kg] Load mass m [kg] 10 10 3 3 10 50 51 100 101 200 100 101 200 10 50 51 Stroke [mm] Stroke [mm] 21 Model Selection MGPK Series L L Plate
(Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.
0 100 200 300 400 500 600 700 0 50 100 150 200 250 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 238 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SLOVENIA SMC Slovenia d.o.o.