Note 2) The time required for 90% valve movement when an actuation pressure of 0.5MPa (72psi) is applied. There is a difference of about 20% in this value at the upper and lower pressure limits.
20 *1 This controls the speed of the slave axis when the speed of the main axis drops due to the effects of an external force and when a speed difference with the slave axis occurs.
Note 2) The time required for 90% valve movement when an actuation pressure of 0.5MPa (72psi) is applied. There is a difference of about 20% in this value at the upper and lower pressure limits.
In case of an emergency, please turn it off.
Maximum stations are 18. 18 6 19 7 20 8 21 9 22 10 23 11 24 1.
Precautions Pull a connector out vertically, never at an angle.
MS-DOS is a registered trade mark of Microsoft Corporation. Pentium is a trade mark of Intel Corporation.
Reduced the attenuation of the ion by an air blow. Equipped with an additional air blow nozzle only for dust removal. Besides the ionized air, the angle and flow rate of the air blow can be adjusted (Optional).
Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable
Compressed air can be dangerous if an operator is unfamiliar with it.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
0.1 0.1 VY130-5 VY140-5 VY150-5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 V V V VY130-6 VY140-6 VY150-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 mA mA mA 4 0 8 12 16 20 4 0 8 12 16 20 4 0 8 12 16 20 2 2 2 VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA mA mA Command signal Command signal Command signal VY1700/1701 VY1900/1901 Command
Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
, 25, 30, 35 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35 40, 45, 50, 75, 100 Surge voltage suppressor Diode (Non-polar: Varistor) 32 1 Indicator light LED Note) The S and Z types of surge voltage suppressor have an internal circuit allowing voltage drop, so use within the following allowable voltage range
-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 2 2 2 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA mA mA Command signal Command signal Command signal VY1700 1 VY1900 1 Input signal voltage (current) for starting the operation of a pilot valve VY1D0 (direct operated) (There
Origin Home Switch Infotmation LX series actuators are available with an optional photo micro sensor as an origin home switch to detect when the actuator is fully retracted. The LCOC seies positioning drjver requires an input from the origin home switch or some other sensor when homing the actuator.