SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AF-20-R"

K 5 T 5 Angle M 10 Z 10 P 0.5 Q 1 R 2 Angle S 3 T 5 Z 10 DIN rail bracket for controller, high voltage power supply module Symbol For controller For high v oltage power supply module Bracket for nozzle Symbol Type Nil Without bracket Nil None None B With L-type bracket U Included Included F With angle adjustment bracket W Included None Y None Included 1-2-1.

Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4

Example)AC30-F03DM-KSTV-13NR-A q r t y w e q Symbol Bodysize Description 20 25 30 40 Rc NPT G Nil N F Threadtype w + 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 Portsize e + Floattype autodrain a Withoutautodrain N.C.(Normalclose)Drainportisclosedwhenpressureisnotapplied. N.O.(Normalopen)Drainportisopenwhenpressureisnotapplied.

3W Z Applicable model AL30 to 60 AL30 to 60 AL30 to 60 AL10 to 60 AL10 to 60 AL10 to 60 AL30 to 60 AL20 AL10 to 60 AL30 to 60 AL10 to 60 Body size F.R.L. 10 20 30 40 50 60 AV Thread type Metric thread (M5) Rc NPT G AU Nil AF N F AL20 Port size AR Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 (2) IR M5 01 02 03 04 06 10 Accessory When more than one specification is

Maximum operating pressure 1.0 MPa AV Regulating pressure range 0.05 to 0.7 MPa 5 to 60C (No freezing) Ambient and fluid temperature AU Filtration 5 m Compact design Recommended lubricant Turbine oil Class 1 (ISO VG32) AF Case Bowl guard provided as standard equipment AU100 has no bowl guard.

Maximum operating pressure 1.0 MPa AV Regulating pressure range 0.05 to 0.7 MPa 5 to 60C (No freezing) Ambient and fluid temperature AU Filtration 5 m Compact design Recommended lubricant Turbine oil Class 1 (ISO VG32) AF Case Bowl guard provided as standard equipment AU100 has no bowl guard.

20 0.7 MPa 0.7 MPa 10 10 0 20 40 60 80 100 0 0 0 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC74 6 ZFC75 8 0.1 MPa 0.3 MPa 0.5 MPa 0.1 MPa 0.3 MPa 30 30 Differential pressure [kPa] Differential pressure [kPa] 0.5 MPa 0.7 MPa 20 20 0.7 MPa 10 10 0 50 100 150 250 200 0 0 0 100 200 300 400 500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC76 10 ZFC77 12 0.1 MPa 0.3

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: W (SI Unit Only)

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Earth Leakage Breaker

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: SI Unit Only

This will cause a malfunction. 8 1 R , 4 1 R G 1 4 The dimensions in ( ): Connecting thread R X2: Stud parts nickle plated 8 1 R PPA 8 1 R , 4 1 R AL 8 1 R , 4 1 R X3: Wetted parts stainless steel MPa 8 1 R 8 1 R , 4 1 R 8 1 R , 4 1 R X4: Oil-free (Wetted parts degreasing) 8 1 R 8 1 R , 4 1 R How to Order G 43 01 Option Connection thread size Symbol Specifications Nil X2 X3 Stud parts nickel

Indication/Setting Parts Description File T ext 001 Model Overlay Numbe Name r No. Indication Type Description (1) Power supply LED (Dark green) Illuminates when power is supplied. Flashes when the supply voltage is irregular.

SUP (SUP air) IN (SIG air) qInput chamber uDiaphragm A iDiaphragm B oSpool wFeedback spring EX OUT2 EX OUT1 eInput diaphragm yNozzle rConnecting rod tCylinder rod 152 Cylinder Positioner IP200 Series Dimensions 20 20 25 SIG OUT1 OUT2 20 25 2 x 6.6 OUT1 OUT2 IN side Rc1/4 38 60 50 SUP 31 35 135 + Stroke IP IP IW 97 1301 40 SUP AW 37 Rc1/4 M8 x 1.25 depth 15 IL1 66 62 + Stroke 80 IL2 Precautions