SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-A-10-M"

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: G (OUT1: NPN; OUT2: External Input), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)

Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: Rc, Port Size: 1", PF2A703H, Output Specification: 28 [NPN + Analog Output (1 to 5 V)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit

Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: Rc, Port Size: 1", PF2A703H, Output Specification: 68 [PNP + Analog Output (1 to 5 V)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit

Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: Rc, Port Size: 1", PF2A703H, Output Specification: 28 [NPN + Analog Output (1 to 5 V)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit

Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: Rc, Port Size: 1", PF2A703H, Output Specification: 68 [PNP + Analog Output (1 to 5 V)], Lead Wire: w/o Lead Wire, Unit Specification: Fixed SI Unit

Flow Rate Range: 150 to 3000 ℓ/min, Port Specification: Rc, Port Size: 1", PF2A703H, Output Specification: 69 [PNP + Analog Output (4 to 20 mA)], Lead Wire: M12 w/3m Lead Wire and Connector, Unit Specification: Fixed SI Unit