Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h. Therefore, the flow rate is calculated as the formula: Q = 0.05/1 x 20 = 1 [kg/h]. 161 VXD Series Flow Rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 157 through to 161.
10.5 40 41 46 20 77 90 102 115 140 12.5 25 37.5 50 75 181 194 206 219 244 27 10.5 Symbol Stroke (mm) With Air Cushion Boss-cut Female Rod End (mm) (mm) Bore size A1 H MM ZZ 20 8 20 M4 x 0.7 95 25 8 20 M5 x 0.8 95 32 12 20 M6 x 1 97 40 13 21 M8 x 1.25 125 Bore size WA 20 13 25 13 32 13 40 16 Bore size ZZ Without With rod boot 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 20 103 130 143
In the case of obtaining an accurate flow rate, refer to pages 31 through to 35. For Air How to read the graph The sonic range pressure to generate a flow of 6,000 L/min (ANR) is P1 0.47 MPa for a 15 orifice (VXZ2 4 B) and P1 0.23 MPa for a 20 orifice (VXZ2 5 C).
Place an order for the cable assembly separately. Kit (D-sub connector) 15 pin F Kit (Flat cable connector) 10 pin, 16 pin, 20 pin P How to Order Manifold How to Order Manifold 06 FSA D VV5Q14 06 P SC VV5Q14 D Ex.) Ex.)
/23-(T) . 8-7 8.4.4 HRSE018-A-20/23-(T) . 8-8 8.4.5 HRSE024-A-20/23-(T) . 8-8 8.5 Pump capacity . 8-9 8.5.1 HRSE012/018-A-10 . 8-9 8.5.2 HRSE012/018/024-A-20/23 . 8-9 8.5.3 OPTION-T (HRSE012/018-A-10-T). 8-10 8.5.4 OPTION-T (HRSE012/018/024-A-20/23-T) . 8-10 8.6 Sample DoC.
Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation. 9.
Model HTB 1 8 Rc CY1S20 CY1S25 CY1L25 CY1S32 CY1L32 CY1S40 CY1L40 20 20 7.5 20 20 7.5 1 8 Rc 20 23 8.2 24 24 7.5 1 8 Rc 26.5 26.5 8.2 25 25 8 1 4 Rc 30.5 30.5 11 Dimensions except mentioned above are the same as standard type of Series CY1B. Refer to page 8-15-24.
If an accurate stopping position is required at the stroke end or midstroke, use an external stopper to secure accurate positioning.
Low temperature operation 1) The valve can be used in an ambient temperature of between 4 to 14F (20 to 10C).
It is deduced from the calculation of the pressure changes inside an air tank when discharging the compressed air in a choked flow, from an equipment attached to the air tank.
, but unassembled. 30 10, 20, 30, 40, 50, 75, 100 40 10, 20, 30, 40, 50, 75, 100 Bore size Strokes are available in 1 mm increments by installing a spacer in standard stroke cylinders. 10 16 20 25 30 40 10 mm 16 mm 20 mm 25 mm 30 mm 40 mm Port thread type M thread Rc NPT G 10 to 20 Nil 25 to 40 TN TF The MQQ series is not auto switch capable.
(Except C kit) F, P, T and S kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. The number of max. stations differs from kit to kit. (Refer to the table below.)
Rod End Lock: -R Bore size (mm) WH W P WA WB 20 30 M5 x 0.8 16 15(16) 23 25 30 M5 x 0.8 16 15(16) 25 32 25 Rc 1/8 16 15(16) 28.5 40 20 Rc 1/8 16 15(16) 33 50 20 Rc 1/4 18 17(18) 40.5 63 20 Rc 1/4 18 17(18) 47.5 80 20 Rc 3/8 22 22 60.5 100 20 Rc 1/2 22 22 71 ( ): Denotes the dimensions for long strokes.
Fit an auto switch into the auto switch mounting groove to set it roughly to the auto switch mounting position for an auto switch. 3. After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the switch. 4. When changing the detecting position, carry out in the state of 2. D1.
Add an in front of the part numbers for solenoid valves, etc. to be mounted.
In the case of obtaining an accurate flow rate, refer to front matter pages 1 to 6. For Air (Orifice size: 10 mm, 15 mm, 20 mm, 25 mm) How to read the graph The sonic range pressure to generate a flow rate of 6000 l/min (ANR) is P1 0.57 MPa for a 15 orifice (VXD214 -03) and P1 0.22 MPa for a 20 orifice (VXD215 -06).
External Wiring Diagram . 20 4.1 CN1: Power connector . 20 4.2 CN2: Motor power connector and CN3: Encoder connector . 20 4.3 CN4: Serial I/O connector . 20 (1) Connection with the teaching box . 20 (2) Connection with a PC . 21 1 - 4.4 CN5: Parallel I/O connector. 21 5.
Standard Stroke Model Standard stroke (mm) MXQ 6 MXQ 8 MXQ12 MXQ16 MXQ20 MXQ25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 D10, 20, 30, 40, 50, 75, 100, 125, 150 -X Individual -X 93 Series MXQ Theoretical Output &' $% The dual rod ensures an output twice that of existing cylinders. ' " # !
Caution When power is applied, it may take approximately 10 seconds (max. 20 sec.) from SVON input to SVRE output depending on the electric actuator position. SETUP and DRIVE can only be accepted during the above conditions. An alarm will be generated at other times.