Size: 46 (42.5 O.D.), Display Pressure: P10 (1.0MPa, 150psi), Connection Thread: 01 (R 1/8), Clear Cover Material: N (Nylon), Attachment: C2 (Clear Cover Removable, Wrench Tighten), Option: X30 (Both MPa and psi)
VH*-OMQ0023-C PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z) VHS40-(F,N)06A,B(-B,S)(-K,R,Z) VHS50-(F,N)06~10A,B(-B,S)(-K,R,Z) VHS2510-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS3510-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS4510-(F,N)02~04A,B(-B,S)(-K,R,Z) VHS4510-(
As a guide, adjust P2, so that it could be W + P2A = P0a.
The small pressure difference (P2 P1) that is created when a part is picked by the (S4) picking nozzle and is detected by the pressure sensor. Wiring is the same as ZSE2. AMJ Vacuum source Pressure sensor Filter case AMV Caution AEP Adsorption nozzle (0.3 to 1.2) 1. The case is made of polycarbonate.
Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.
Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.
Nq Body size 10 20 25 30 40 Symbol Description Nw Pipe thread type Nil Metric thread (M5) V Rc V V V V N NPT V V V V F G V V V V + M5 M5 V 01 1/8 V 02 1/4 V V V V 03 3/8 V V V 04 1/2 V 06 3/4 V + Ne Port size a Mounting Nil Without mounting option V V V V V B Note 2) With bracket V V V V V H With set nut (for panel mount) Note 3) V V V V V + Option Note 1) Nr Nil Without pressure gauge
As a guide, adjust P2, so that it could be W + P2A = P0a.
As a guide, adjust P2, so that it could be W + P2A = P0a.
7 A(2) port P2(12) port w !2 !6 !4 !
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
LED LED OFF IP NS EtherNet/IP IP OFF MS EtherNet/IP LED 10Mbps P2-100 EtherNet/IP 100Mbps / P2-L/A / / / 10Mbps P1-100 EtherNet/IP 100Mbps / P1-L/A / / / -29No.JXC-OMT0001CN-C 4.4. 1 2DIN -30No.JXC-OMT0001CN-C 4.5 (1) DIN (A) (M5 4 ) (M5)X4 () (b) DIN (DIN ) DIN M5X8DIN 2 4 (:3.0[Nm]) M5X8 (M5X14)1 DIN 2 2 :3.0[Nm] DIN () A DIN B M5X14 M5X14) DIN (:
How to Find the Flow Rate (at air temperature of 20C) Choke flow: when (P2 + 0.1)/(P1 + 0.1) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply
How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are
ARP30-02BG For 0.4 MPa setting 1 l/min (ANR) or less (at P2 = 0.4 MPa) Air consumption Ex.) ARP30-02BG-1 For 0.2 MPa setting 0.6 l/min (ANR) or less (at P2 = 0.2 MPa) Ex.)
ARP30-02BG For 0.4 MPa setting 1 l/min (ANR) or less (at P2 = 0.4 MPa) Air consumption Ex.) ARP30-02BG-1 For 0.2 MPa setting 0.6 l/min (ANR) or less (at P2 = 0.2 MPa) Ex.)
= 0.5 MPa 0.5 P B 64 33 28 0.4 A EA 36 75 78 Effective area at exhaust side (mm2) S at P2 = 0.5 MPa 0.3 B EB 68 38 69 0.2 Note 1) Set the pressure within the operating pressure range of the solenoid valve.