Description (The gure shows the HRS-150-A-20.) q Hose (I.D.: 0.6 in [15 mm], Length: 27.5 in [700 mm]) Relief valve set pressure: 46 psi [0.32 MPa] (The relief valve starts to open when the circulating fluid discharge pressure reaches 46 psi [0.32 MPa] .)
Prefix it to the part nos. of the solenoid valve, etc. 5-4-6 3 Port Air Operated Valve Series SYJA500/700 Specifications Fluid Operating pressure range (MPa) Pilot pressure range (MPa) Note 1) Air 0.15 to 0.7 (0.4 x P + 0.1) to 0.7 P: Operating pressure range Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note 2) 10 to 50 (No freezing
Clean Room Rodless Cylinder Series CYP 15, 32 MX MTS MY CY MG CX D-X 20Data Magnetically coupled rodless cylinder for transfer in clean environments. 8-17-1 Low particle generation: 1/20 Long stroke (Max. 700 mm) (compared to previous series) High cleanliness is achieved with non-contact construction of the cylinder tube exterior and a stainless steel linear guide (specially treated).
Check the outlet air set temperature from the intersection point of the curve indicating a pressure dew point of 50F (10C) and an air flow capacity of 24.7 scfm (700 L/min [ANR]). It is possible to confirm that the outlet air set temperature can be set up to 80.6F (27C). F It is not possible to control the required outlet air set temperature. Review the operating conditions.
Chart (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2.
0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 10% 30% 50% 70% 150 Stroke (mm) Stroke (mm) Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 CM2 25 200 150 AS2201F -01-06 AS2200-01 100 50 0 SV100 ANA1 -C08 T0604 CM2 32 200 150 AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) [MPa] 0.8 Subsonic 0.9 0.6 Critical pressure 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 2 50 100 150 200 250 300 400 350 3 100 200 300 400 500 4 400 600 800 1,000 1,200 5 200 1,400 600 1,000 7 350 700 8 400 700 1,000 1,300 10 (Connection: 1/4) 500 700 10 (Connection: 3/8, 1/2) Flow rate Q [L/min (ANR
Stroke (mm) up to 10 up to 30 up to 50 up to 75 up to 100 Max. speed (mm/s) up to 400 more than 400 up to 400 more than 400 up to 400 more than 400 up to 400 more than 400 up to 400 more than 400 6 5 6 7 10 15 Selection graph 14 15 20 8 9 10 11 12 13 25 32 The maximum speeds for 6 to 32 are: 6, 10: up to 800 mm/s; 15, 20: up to 700 mm/s; 25, 32: up to 600 mm/s Caution If the cylinder is
Mitsubishi Electric Corporation Yaskawa Electric Corporation LJ1H202NA 100W to 500 LJ1H303SE 200W to 500 to 500 to 500 LJ1H202PC 100W to 1000 to 740 to 930 to 600 to 500 LJ1H202NC 100W to 740 to 930 to 600 to 500 to 1000 LJ1H303PD 200W to 1000 to 1000 to 1000 to 700 to 500 LJ1H303ND 200W to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 100W to 400 LJ1H102NH-K 100W to 400 LJ1H202PF-K 100W
Mitsubishi Electric 30 guide 100W 0.02 Ground ball screw Corporation 1000 Yaskawa Electric 100W 0.05 Rolled ball screw Corporation Features 1 Simplified Selection Flow Chart Series LJ1/LG1 Page Standard stroke (mm) and Speed (mm/s) Nonstandard motor Model Standard motor Clean room Dust seal Deflection TSUBAKI 100 200 300 400 500 600 700 800 900 1000 1200 1500 CABLEVEYOR LJ1S101SC 88
Silencer 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 400 MB 32 10% 30% 50% 300 70% Stroke mm AS2201F -01-08 AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700
Double acting, Single rod Action 20, 25, 32, 40 Bore size (mm) 0.7 MPa Maximum operating pressure 0.15 MPa Minimum operating pressure Rubber bumper Cushion Built-in One-touch fitting Piping 20 25 32 40 Piston speed (mm/s) 50 to 700 50 to 650 50 to 590 50 to 420 Application/Tubing O.D.
Ordering example) 10 B X10 IZS 40 1660 X10 10 B IZS 42 1660 Type 41 42 Bar length 520 1000 1420 1780 2140 700 1060 1480 1840 2200 760 1180 1540 1960 2260 880 1240 1660 2020 2380 940 1360 1720 2080 2440 Symbol Contents Specifications The main unit is shipped fitted with a drop prevention cover available as an option -X14 Model with drop prevention cover 1-2.
It may be out of this range in some other operating conditions. 7 Thermo-con/Rack Mount Type Air-cooled HECR Series Cooling Capacity HECR002-A HECR-A Air-cooled Water-cooled HECR-W Model Selection Specific Product Precautions Options Optional Accessories Circulating fluid: Ethylene glycol 20% Circulating fluid: Tap water 800 800 700 700 Cooling capacity [W] Cooling capacity [W] Ambient temperature
For installation indoors, ventilation ports and a ventilation fan should be equipped as needed. 700 mm or more 300 mm or more Electrical Wiring Warning 1. Grounding should never be connected to a water line, gas line or lightning rod. Caution 1. Communication cable should be prepared by the customer.
HED q Hose (I.D.: 15 mm, Length: 700 mm) w Outlet piping assembly (With globe valve) Relief valve set pressure: 0.32 MPa (The relief valve starts to open when the circulating fluid discharge pressure reaches 0.32 MPa.)
Slide table Cylinder tube Special cylinder tube Long stroke (Max. 700 mm) A special cylinder tube using extruded aluminum material is employed.
, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
Flow Direction Symbols on Body Meter-out type Meter-in type Flow Rate and Effective Area Symbol JIS Symbol ASD230F ASD330F ASD430F ASD530F ASD630F Model 6 8 10, 12 10 12 Metric size 4, 6 8, 10 1/8" 5/32" 3/16" 1/4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min}
Fan motor Outlet thermometer Model Selection (Flow Capacity l/min (ANR)) HAA7 HAA15 HAA22 HAA37 Model Outlet side air (COOL AIR) 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000 Inlet air temperature 4300 Cooling side air Cooler Conditions: Outlet temperature 40C, Ambient temperature 32C, Air pressure 0.7 MPa Drain 14-15-1 2 Series HAA How to Order Precautions 15 10 D 1