Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore Size: 10, Stroke: 100mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting,
Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore: 10mm, Stroke: 100mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9N, Lead
The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Head Cover Port Position: 90° to axis, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: Clean Series, Auto switch mounting bracket: N/A, Type: Clean Series (relief type)
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.06 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.056 lb. 359.
Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.092 lb
(mm) At the minimum stroke of 25 mm adjustment bolt Basic stroke At maximum stroke adjustment At the minimum stroke of standard adjustment bolt Bore size (mm) Bore size (mm) 10 15 25 Adjustment bolt fixing bolts Tightening torque Adjustment width across flats 10 15 25 A 2 A 26 A = 0.8 A = 0.6 A 0 M3 1.0 to 1.3 Nm 4 A 2 A 26 CY3B CY3R M5 4.6 to 6.2 Nm 5 CY1S Adjuster holder A CY1L Adjuster
Supply voltage Minimum operating voltage of load > Internal voltage drop of switch 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (model D-A80/A80H/A90/A90V).
When using a stopper cylinder for intermediate stopping of a load connected directly to a cylinder, etc. The operating ranges shown in this catalog apply only for stopping of a pallet on a conveyor. When using a stopper cylinder to stop a load connected directly to a cylinder, etc., the cylinder thrust will become a lateral load.
Be certain to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. 5. There may be cases in which a speed reduction circuit or a shock absorber is required.
2 A A-A' Piston rod section A' !1 !3 !4 Component Parts No.
: A12 Symbol: A13 Symbol: A14 Symbol: A15 R sphere C0.5 DA DA AL MM DA C C DA 30 30 30 H A A H H A H W1 T C Symbol: A16 Symbol: A17 Symbol: A18 Symbol: A19 MM AL DA MM 30 30 30 30 MM MM H A H A H A C H A 46 CP96N/C96N Series Symbol Change of Rod End Shape 1 -XA0 to XA30 Symbol: A20 Symbol: A21 Symbol: A22 Symbol: A23 RD 30 30 MM 30 DA MM 30 DA MM L DB DB C H A T H A T H A B W H A L K Symbol
This produces an air cushion cylinder which retains the merits of a compact design. Operating principle A + A' A' qWhen the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. wAfter piston seal H has passed the air passage A, exhaust is discharged only from A'.
Supply Internal voltage Minimum operating > voltage drop of auto switch voltage of load 2) If the internal resistance of a light emitting diode causes a problem, select an auto switch without an indicator for right (MODEL D-A90 , A90V)