KQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-01 KQ2P-03 KQ2P-07 KQ2P-09 3.2 4 6 8 16 16 18 20.5 31.5 32 35 39 1/8" 5/32" 1/4" 5/16" 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 5 6 8.5 10 Port plug VVQ0-58A The plug is used to block the cylinder port.

(Refer to p.4.9-5) Caution Model Recommended SMC speed controller Caution Model Elbow Straight In-line REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC32 AS3201F-01-08-X214 AS3001F-08-X214 AS3201F-01-08-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 4.9-3 Be sure to read before handling.

Metric size Inch size Control 3.2 23 01 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Meter-out Meter-in 0 1 04 06 08 10 12 03 05 07 09 11 13 4 6 8 10 12 With One-touch fitting Use 1/8" tube. 15-9-92 2 Tamper Proof Speed Controller With One-touch Fitting, Elbow Type/Universal Type Needle Valve/Flow Characteristics AS121F AS131F AS221F-01 AS231F-01 AS221F-02 AS231F-02 Inlet pressure: 0.5 MPa Inlet

,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC40B,C,D -(F,N)02~(F,N)04(C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,ZA)-D AC40(A)-(F,N)06(C,D,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC40B,C,D-(F,N)06(C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,ZA)-D AC50(A)-(F,N)06(F,N)10(C,D,E,E1,E2,E3,E4,G,M)-(1,2,3,6,8,J,N,R,W,Z,ZA)-D AC50B-(F,N)06(F,N)10 (C,D,E,E1,E2,E3,E4,G,M)-(1,2,6,8,J,N,R,W,Z,

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I

KPGH04-02 KPGH06-M5 KPGH06-01 KPGH06-02 KPGH08-01 KPGH08-02 KPGH10-02 KPGH10-03 KPGH12-03 KPGH12-04 KPQH04-M5 KPQH04-01 KPQH04-02 KPQH06-M5 KPQH06-01 KPQH06-02 KPQH08-01 KPQH08-02 KPQH10-02 KPQH10-03 KPQH12-03 KPQH12-04 24.4 24.9 23.5 21.4 25.3 25.8 23.7 24.6 30.7 29.1 36.1 30.9 32 32.2 8 M5 x 0.8 21.5 10 4 M A L 17 4 4 4 10 14 18.5 16 1/8 1/4 7 12 H Connection threads 8 22 12 5 M5

-01-06 VZM550-01-06S Toggle lever VZM550-01-08 PAT.

20 BM1-02 25 BM1-32 32 BM1-04 40 BM1-05 50 BM1-06 63 BA-01 20 BA-02 25 BA-32 32 BA-04 40 BA-05 50 BA-06 63 BA-08 80 BA-10 100 Courtesy of Steven Engineering, Inc. !

ASD230F-M5-04D-X12 744 ASDF-D Series Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting How to Order ASD 3 3 0 F 01 06 S D Made to Order Lubricant: Vaseline X12 AS-F Ex.)

Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006

Model Optional specifications AW10(K) AW20P-270AS AR20P-260S AW20(K) AW30(K) AR40P-270AS AR40P-260S AW40(K) AW40(K)-06 AW60(K) AW60P-270AS Note 6) Bracket assembly Note 1) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AR30P-270AS AR30P-260S Note 7) Set nut G36-10-01 G36-2-01 G36-10-01-L G36-2-01-L G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L Round type Note 2) Standard 0.02 to 0.2 MPa

X Port size) Silencer System Solenoid valve Speed controller VFS 4 X 1/8 AS2301F01-04 A VS SYJ5l40-01 Rc(PT)1/8 (S = 4.5mm2) AS2301F01-06 B VS7 AN110-01 (S = 35mm2) Plate fixing screw 6 X 1/8 AS3301F -06 02 03 C 8 X 1/8 AS3301F -08 02 03 D Note) Do not loosen plate fixing screw. 1.2-31 Series SYJ5000 How to Order Light and surge voltage suppressor For electrical entry G,H,L and M Configuration

Function selection mode ON OFF Front protective cover (Model: ZS-27-01) Connector Connecting / Disconnecting When mounting the connector, insert it straight into the socket, holding the lever and connector body, and push the connector until the lever hooks into the housing, and locks.

ERR 00: CPU Hung up ERR 01: CPU Check Failure ERR 03: Back-up Data Error ERR 04: EEPROM Writing Error ERR 05: EEPROM Input Over Times Error ERR 11: DC Power Voltage Failure ERR 12: Internal Sensor Value is High ERR 13: Internal Sensor Value is Low ERR 14: Thermostat Alarm ERR 15: Output Failure Alarm (Abnormal output) ERR 17: Cutoff/Short of Internal Sensor ERR 18: Cutoff/Short of External

(When double solenoid is mounted) Solenoid B Solenoid A C2 (When double solenoid is mounted) B3 (When the needle is fully open) B2 2 x metering valve with silencer (EXH) ASN2-M5 (CVRB1BW50) ASN2-01 (CVRB1BW80, 100) Note 1) Solenoid valve in external appearance is for VZ 140-1G.

(SMC's inspection conditions) *2: The period of time from gate open state to clamp after signals comes to solenoid valve and from gate clam Conditions Pressure: 0.5MPa , Pipe length:1m, Gate Direction: Vertical Upper, Without Speed Controller, Solenoid Valve:SY5120-01 , Tube:TU0604 4 - 2.

Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG (-) 0E ESTOP 0E JOG (+) 0F ALARM 0F FLGTH 10 to 1A

Setting "21" to "27" will trigger [AL. 37] in the mode other than the positioning mode. 00: Cumulative feedback pulses 01: Servo motor speed 02: Droop pulses 03: Cumulative command pulses 04: Command pulse frequency 05: Analog speed command voltage (Note 1) 06: Analog torque command voltage (Note 2) 07: Regenerative load ratio 08: Effective load ratio 09: Peak load ratio 0A: Instantaneous