Body Size: 10, Fitting Size: 06 (ø6)
Bracket Type: C (Single Clevis), Applicable Bore Size: 06 (63mm)
Type: Inline Filter, Compressed Air Quality: General Dry Air, Treatment Air Flow Rate(l/min): 100, Connection Type: [One-Touch Plumbing] One-Touch Pipe, Plumbing Thread Nominal: -, Connecting Tube Diameter: Ø6, Filtration Level: 0.01μm, Operating Environment: Standard, Drain Cock: No, Bowl Material: [Resin] Polycarbonate Case, Bowl Guard: No, Accessory: None, Connection type on OUT side:
Bracket Type: Single Clevis, Applicable Bore Size: 63mm
Type: Retainer Pin/Stopper Set, Cover: N/A, Element Material: [Resin Base] Sound Absorbing Resin, Main Body Material 1: [Resin] Resin, Flow Coefficient (Cv)(mm2): 7, Silencing Effect(dB): 30, Pipe Connection Port Type: One-Touch Pipe, One-Touch Fitting Size: φ6, Outer Diameter D(φ): 11, Effective Sectional Area Class(mm2): Up to 10, Recommended Flow Rate(m3/min(ANR)): 0.8 or less
Type: Bulb, Type: Metric size, Connection Port Size: 6, Option: No bracket
Body Size: 20 [Max Flow 240 â„“/min (ANR)], Single Sided Connections: Single Sided Connections, Fittings: Straight, Connection Tubing O.D.: ø6mm, Bracket: -, Accessory: -, Panel Mounted Switch: -
Size: 1, Standard Dew Point: -20°C, Type: Standard, Thread: C (ø6 One-touch Fitting), Port Size: 06 (ø6)
Types: Dryers, Method: Hollow Fiber Type, Shape: Flexible, Outlet Flow Rate(l/min): 10, Outlet Open Air Pressure Dew-Point(°C): -20, Exit Flow Rate Class(l/min): Up to 50, Supply Side Connection Type: One-Touch Pipe, Body Material: Metal, Inlet Air Temperature(°C): 25, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: -, Supply Side Connecting Tube Diameter: Ø6, Control Side
Size: 1, Standard Dew Point: -20°C, Type: Standard, Thread: C (ø6 One-touch Fitting), Port Size: 06 (ø6), Accessory: None (Standard), Option: P (Fitting for Purge Air Exhaust)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MUFFLER, AIRLINE EQUIPMENT, AN SILENCER, FX, AN 1/2INCH (MISC./OTHER), .20680 lb
The IRV series vacuum regulator is offered in 3 compact, lightweight sizes. Adjustment resolution is possible within 0.13kPa. Port sizes available are 1/8Rc(PT), and 1/4, 3/8 and 1/2 with Rc(PT), NPT or G(PF) thread types.Single sided connections series, Mass reduced by 20%, Max. flow 140 /min (ANR) and 240 /min (ANR), Integrated digital pressure switch for panel mounting, Built-in one-touch
The IRV series vacuum regulator is offered in 3 compact, lightweight sizes. Adjustment resolution is possible within 0.13kPa. Port sizes available are 1/8Rc(PT), and 1/4, 3/8 and 1/2 with Rc(PT), NPT or G(PF) thread types.Single sided connections series, Mass reduced by 20%, Max. flow 140 /min (ANR) and 240 /min (ANR), Integrated digital pressure switch for panel mounting, Built-in one-touch
The IRV series vacuum regulator is offered in 3 compact, lightweight sizes. Adjustment resolution is possible within 0.13kPa. Port sizes available are 1/8Rc(PT), and 1/4, 3/8 and 1/2 with Rc(PT), NPT or G(PF) thread types.Single sided connections series, Mass reduced by 20%, Max. flow 140 /min (ANR) and 240 /min (ANR), Integrated digital pressure switch for panel mounting, Built-in one-touch
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
The MU plate cylinder, with its elliptical design, provides a low profile while maintaining force output. The MU cylinder can eliminate the need for higher operating pressures that may be required for typical flat cylinders. The oval piston shape also provides an intrinsic non-rotating function without having to use a rod with flats, offering increased bearing and seal life.Single acting
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
Membrane air dryer series IDG is available in a single unit or combination unit style. IDG/M models combine a mist separator and micro mist separator with a single unit. IDG/V models combine a regulator with the IDG/M model. Options available include one-touch fitting exhaust of purge air. If purged air is not exhausted around membrane air dryer, air is exhausted with tubing away from its
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SILENCER, HIGH NOISE REDUCTION, AIRLINE EQUIPMENT, AN SILENCER, EX, AN 3/8INCH (MISC./OTHER), 2.08938 lb
Pneumatic-electric relay series VR32 converts pneumatic signal to electric relay. Series VR3100 indicates the presence of pneumatic pressure. It is equivalent to the pilot lamp of an electrical system. Series VR3110 is an ultra-compact air indicator light to monitor the presence of air pressure. It is equivalent to the pilot lamp of an electrical system.Operating pressure: 0.25 to 1 MPa,