), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector)
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector)
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)
This is a legacy product, and replaced byPF2MC7202-N06-F, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 1.06494 lb
This is a legacy product, and replaced byAC40A-N06-38Z-B, FR/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, GC, AC MASS PRO 3/4 MODULAR (NPT), 4.18878 lb, ModelComponentPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 2)Proof pressureMaximum operating pressureSet pressure rangeRelief pressureNominal filtration ratingRecommended lubricantBowl materialBowl
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, FC, AL MASS PRO 1/2 MODULAR (NPT), 1.20061 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, GC, AL MASS PRO 3/4 MODULAR (NPT), 1.46918 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, EC, AL MASS PRO 3/8 MODULAR (NPT), 1.15742 lb
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Part Number Description: REPAIR KIT FOR XT13-207-N06 Product Line: E Product Line Description: AIRLINE EQUIPMENT Click here to report information errorImage shown may not match exact part number
Part Number Description: REPAIR KIT FOR XT13-207-N06 Product Line: E Product Line Description: AIRLINE EQUIPMENT Click here to report information errorImage shown may not match exact part number
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge