SMC Corporation of America
Elite Part Number Search
Search Results "AC41-N04-8RZ-B-X2217A"

300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector)

), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: P (w/Unit Switching Function, Initial Value psi), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: P (w/Unit Switching Function, Initial Value psi), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

Type), Vacuum Pressure Sensor: None, Output: B (PNP Open Collector), Unit: P (w/Unit Switching Function, Initial Value psi), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector)

Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector

300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: P (w/Unit Switching Function, Initial Value psi), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

w/Lead Wire 300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

w/Lead Wire 300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: M (SI Unit Only, kPa), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)

Vacuum Pressure Sensor: F (Vacuum Pressure Switch, Compound Pressure 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)

This is a legacy product, and replaced byAR40-N04-Z-B-X48, REGULATOR, MODULAR, EPOXY COAT, AIRLINE EQUIPMENT, AR MASS PRO, FC, AR MASS PRO 1/2 MODULAR (PT), 1.03620 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital

), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: None, Output: B (PNP Open Collector)

The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Air filter, regulator and lubricator unit , Clean looking, modular design

Size: 40 (1/2), Port Size: 04 (1/2, Size 40), Accessories: None, Bowl: 8 (Metal Bowl w/Sight Glass), Flow Direction: R (Flow Direction - Right to Left)

Size: 1/2, Port Size: 1/2, Size 40, Accessories: None, Bowl: Metal Bowl w/Sight Glass, Flow Direction: Flow Direction - Right to Left

Size: 1/2, Model Combination: AF+AR+AL, Port Size: 1/2, Size 41, Accessory: None, All Sizes, Pressure Relief Valve: Downstream Valve, Option: Metal Bowl w/Sight Glass, Size 31 & 41