SMC Corporation of America
Elite Part Number Search
Search Results "25A-VQ2A01-51"

SYJ312 SYJ322 SYJ332 SYJ342 SYJ352 SYJ314 SYJ324 SYJ334 SYJ344 SYJ354 SYJ313 SYJ323 SYJ333 SYJ343 SYJ353 2 position 0.9 (0.05) 5 Port Body ported type M3 0.5 50 54 3 position 59(33) 73(47) 61(35) 77(51) 2 position 5 Port Base mounted type (With sub-plate) 1.8 (0.1) Body ported type M5 0.8 76(50) 80(54) 3 position 33 47 35 51 2 position 4 Port Base mounted type For manifold use only Note1

(SeeLECSB Operation Manual (Simplified Edition), section 5.3.2 for uploading.) 51 - 5.8.2 To Load saved Parameters From the Project menu in the setup software, select Open. Please select the "drive path name project name" that you want to read parameters are stored. Click Open.

If over a certain period of time in the state of the pressing position, an overload alarm (AL 50, AL 51) occurs for driver protection. (1) Devices, parameters Set the input devices and parameters as follows: Item Device/Parameter used Description Automatic/manual selection (RYn6) (MD0) Turn RYn6 ON.

Reverse rotation is indicated by a minus (-) sign. -9 to 9 pulse -51- No. Name Function Display range Unit 4 Cumulative command pulses The position command input pulses are counted and displayed. Press the [Clear] button to reset the display value to zero.

(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.

This means that the output can become energized anywhere between 49 to 51 [kPa]. (Refer to the chart below.) Note: If the pressure switch allows an error of 1 [% F.S.], the output turns ON at 51 [kPa]. Taking the repeatability into account, the output turns ON at 50 to 52 [kPa] and, in the same way, the pressure display turns 50 [kPa] at 49 to 51 [kPa]. (Refer to the chart below.)

18 41 6 60.4 62.4 36.1 38.1 31 54 56 17 14 41 1 8 1 4 3 8 8 18 41 62.2 26.2 36 16.5 3.5 18.7 11 9.7 1.2 31 58 17 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHKl-08F-01S VHKl-08F-02S VHKl-08F-03S 65.2 66.2 39 40 32 59 60 19 22 40 1 4 3 8 1 2 10 22 46 73.8 30.5 43.3 21.5 4 20.8 14 16.1 3.2 49 VHK-B2A 49 17 1 30 25 21.5 31 VHKl-10F-02S VHKl-10F-03S VHKl-10F-04S 74.8 78.2 44.3 47.7 51 68 17 19 72 70

) 46.5(57) 46.5(57) 50(66) 8.5 11.5 11.5 11.5 22 25 25 25 20 23 25.5 25.5 56 61 61 65 64 75.5 82 82 30 35 40 40 XSA12S(V) XSA22S(V) XSA3-32S(V) XSA3-43S(V) P DIN terminal M L Model G 59 60 63 H 48 58.5 64 64 63 J 47 48 51 51 (Unit: inch) 1/4 1/4 1/4 3/8 8 10 10 10 3 5 5 5 XSA12S(V) XSA22S(V) XSA3-32S(V) XSA3-43S(V) 34 High Vacuum Angle Valve Series XL 1 With pilot pressure at 0.5MPa (72psi

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: -, Seal: -, Function: -, Coil Voltage: -, Light & Surge Suppressor: -, Manual Override: -, Enclosure: -, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: 4 Position Dual 3 Port Valve N.C./N.C., Seal: Rubber Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking, Tool Required, Enclosure: Dust Protected, Sub-plate: -, Thread: -, CE Compliant: -

Actuation: 4 Position Dual 3 Port Valve N.C./N.C., Seal: Rubber Seal, Function: Standard (0.4W DC, AC), Coil Voltage: 24VDC, Light & Surge Suppressor: Yes, Manual Override: Locking, Tool Required, Enclosure: W [Dust-tight, Water-jet-proof (IP65)], Sub-plate: -, Thread: -, CE Compliant: -

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] 4 positions (N.C. + N.C.), Applicable Cylinder Diameter(Ø): -, Pressure Rating(MPa): 0.15~0.7, Driving

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] 4 positions (N.C. + N.C.), Applicable Cylinder Diameter(Ø): -, Pressure Rating(MPa): 0.15~0.7, Driving

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] 4 positions (N.C. + N.C.), Applicable Cylinder Diameter(Ø): -, Pressure Rating(MPa): 0.15~0.7, Driving Type: Pilot

Actuation: A (4 Position Dual 3 Port Valve N.C./N.C.), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected