SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXQ20-20C"

Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232

. *5 Inlet pressure: 0.7 MPa Flow at 20C, atmospheric pressure, and 65% of the relative humidity 7 Compressed Air Preparation Filter AFF/AM/AMD Series Line Filter AFF Series Flow Rate Characteristics (Representative values) AFF/AM/AMD AMK Modular Connection Example Compressed air over the max. flow capacity line in the table below may not meet the specifications of the product.

/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C

3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow Free flow Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 1580 1710 460 920 Sonic Conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C

MPa Min. operating pressure 5 to 60C (No freezing) Ambient and fluid temperature 20 turns 10 turns Number of needle rotation With seal Option 74 11.5 36 Weight (g) Flow rate (l/min (ANR)) 38 7 12 Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (l/min (ANR)) 420 105 280 Effective area (mm2) JIS Symbol Free flow 6.5 1.6 4.3 Note 1) Flow rate values are measured at 0.5 MPa and 20C

TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.

REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 7 12 Air flow (l/min (ANR)) 38 Controlled flow CX 0.1 0.2 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C In-line Type RHC Air Flow/Effective Area MK(2) AS2001FM

Elbow Type (Metal body) Air Flow/Effective Area AS220M-02 AS120M AS220M-01 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size Rc 1/4 Tube side Rc 1/8 Air flow (L/min (ANR)) 38 7 12 REA Controlled flow Effective area (mm2) 0.6 0.1 0.2 Flow rate (L/min (ANR)) 420 105 280 REB Free flow Effective area (mm2) 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature: 20C

Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 minute, AC 1000 Cannot be used for transfer wiring.

Property 65 or less Cable length (L) Conductor resistance /km, 20C AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 1.5 m 3 m 5 m Cable 25-core x 24AWG 10 Voltage limit V, 1 min, AC 1000 Cannot be used for transfer wiring.

The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures.

Fixed end Bend the tube into the U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the deformed ratio of the tube diameter at bending reaches 5%.

REC 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size 12 7 Air flow (l/min (ANR)) 38 Controlled flow CX 0.2 0.1 Effective area (mm2) 0.6 CY 100 180 230 260 390 460 Flow rate (l/min (ANR)) Free flow 1.5 2.7 3.5 4 6 7 Effective area (mm2) MQQ M Note) Supply pressure: 0.5 MPa, Temperature: 20C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C

degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig

Note2) Conditions that radiating water temperature is at 20C, radiating water flow rate is at 5 L/min, setting temperature is at 20C and ambient temperature is at 20C Note3) External sensor should be prepared by customers. Note4) Reservoir cap, Handle, Drip proof cover, connector are not included.

O.D. 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 1/4" 5/16" 3/16" 1/4" 1/8" 5/32" Inch size 3/8" 5/16" 3/16" 1/4" Flow Direction Symbols on Body Meter-out type Meter-in type Flow rate (l/min (ANR)) Controlled flow (Free flow) 100 180 230 260 390 460 660 790 920 1580 1710 Symbol Effective area (mm2) 1.5 2.7 3.5 4 6 7 10 12 14 12 26 Note) Flow rate values are measured at 0.5 MPa and 20C

Symbol Proportional Solenoid Specifications Max. current 1A VEA250,VEA251 Applicable power amplifier 13W(20C, With maximum current) 13(20C) Coil resistance Rated power consumption Class H or equivalent (180C) Coil insulation 140C(With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Mounting screw (With washer) M5 X 45 VER2000 VER4000 Model AXT500-13

Burst pressure 25 20C to 60C Nylon 12 Min. bending radius (mm)(1) Operating temperature Material Note 1) The value at temp. of 20C and with O.D. variable rate 10% max.

Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.