V 12 V V 12-2 12-1 1. 1 2 2. 3.
IC circuit Reed switch Solid state switch A96 A96V 5 V Grommet Yes Relay, PLC A93 A93V 12 V 2-wire 24 V 100 V 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) M9P M9PV 2-wire M9B M9BV 12 V Relay, PLC 3-wire (NPN) F9NW F9NWV 5 V, 12 V 24 V IC circuit Grommet Yes Diagnostic indication (2-color) 3-wire (PNP) F9PW F9PWV F9BW F9BWV 12 V 2-wire Water resistant (2-color) F9BA Although it
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
12 bit Ry1B Ry1A Ry19 Ry18 ID 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 12 1 1 0 0 44 - 13.
(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133
(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133
Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR SIGNAL OUTPUT . 12-1 12.3 REMOTE OPERATION . 12-2 12.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 12-3 12.5 ELECTRIC CIRCUIT . 12-4 Chapter 13 Option V . 13-1 13.1 SAFETY INSTRUCTIONS FOR USE . 13-1 13.2 SPECIFICATIONS . 13-1 13.3 MAINTENANCE . 13-2 Chapter 14 Inspection record . 14-1 14.1 INSPECTION RECORD .
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 13-1 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDFA60/70/80/90 Series IDX-OM-W094 1 1.1 z z z z z z z z z () 6.2 z 1.1.1 3 IDFA60/70/80/90 Series 1-1 IDX-OM-W094 1.2 6 1.2.1 1.2.2 50 1.2.3 0 IDFA60/70/80/90 Series 1-2 IDX-OM-W094 1.2.4 IDFA60/70/80/90 Series 1-3 IDX-OM-W094
9 125 110 176 160 16 18 107 38 60 125 95 45 194 42 M10 200 95 12 11 135 115 210 190 82.5 19 23 142 50 75 150 115 MGG Bore (mm) Z Y X W WH W V U T S R Q O P MGC 20 25 32 40 50 140 80 30 30 23 36 40 86 12 26 12 21 M6 X 1 M5 X 0.8 MGF 153 80 37 30 25 44 47 98 13 31 12 21 M6 X 1 M5 X 0.8 161 82 37 25 28.5 50 53 112 16 38 12 21 M6 X 1 Rc(PT)1/8 CY1 188 92 44 20 33 60 63 132 20 47 12 25 M8 X 1.25
Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended fluid and ambient temperature range provides best performance and longest life.
, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
to 300 Speed*1 [mm/s] 501 to 600 30 to 1200 20 to 850 10 to 300 Actuator specifications Parallel Stroke range Up to 500 20 to 900 12 to 600 6 to 300 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 501 to 600 30 to 750 20 to 550 10 to 300 Max. acceleration/deceleration [mm/s2] 3000 Positioning repeatability [mm] 0.01 (Lead H: 0.02) Lost motion [mm]*2 0.05 Lead [mm] 20 12 6 24 16
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Model Port size Note 2) INLET OUTLET Rated flow rate (L/min) FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1B 1/2B 20 1B 3/4B 50 1 1/2B 1B 100 1 1/2B 1 1/4B 150 2B 1 1/2B 200 2B 2B 300 2 1/2B 2 1/2B 450 3B 3B 600 3 1/2B 3 1/2B 750 4B 4B 900 Note 2) Both flange
Name Material Remarks 1 Body Stainless steel 2 Spool Special stainless steel 3 Sleeve Special stainless steel 4 Plate Aluminium 5 O-ring H-NBR 6 Retaining ring Carbon steel 7 Retaining ring Carbon steel 8 Radial bearing MQR2 to 12-M5 Components / (MQR2 to 12 M5, 2 to 12 circuits) No.
\u/ (6oomm) Lead wire length :12 inch (300mm) L: L type plug connector with lead wire H"rt#'" mhrin*n" : 12 inch | ll-l.r :12 inch (3oomm) "!
It is necessary to set it on the PLC side according to the kind of PLC. 38 - 6.3 The recommended value of the parameter [LEY] LEY25/ LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Initial value Recommended value Parameter *1,*2 Para.
2-wire 12 V Connector Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V 24 V 2-wire Grommet Water resistant (2-color indicator) 12 V F7BA F7BAV With diagnostic output (2-color indicator) IC circuit F79F 4-wire (NPN) 5 V, 12 V 3-wire (NPN equivalent) IC circuit A76H 5 V A72H A73H A80H A72 A73 A80 A73C A80C Grommet 200 V 100 V 12