SMC Corporation of America
Elite Part Number Search
Search Results "11-LEFS25S2A-100-R2"

T Connecting thread KBB1-M5 KBB1-M6 KBB3-R1 KBB4-R2 Rc(PT)1 4 Rc(PT)1 8 M6 X 1 M5 X 0.8 T Connecting thread Part No.

Pressure range Switch 100 kPa 0 100 kPa 500 kPa 1 MPa For vacuum pressure ZSE10 0 101 kPa 105 kPa 10 kPa For compound pressure 100 kPa 100 kPa ZSE10F 105 kPa 105 kPa For positive pressure 100 kPa 1 MPa ISE10 105 kPa (0.105 MPa) 1.05 MPa Rated pressure range of switch Set pressure range of switch Back page 4 Revision history Acquisition of UL standards.

In the default settings, the resolution of the 100 L/min type is 1 L/min, and the 10 L/min type is 0.1 L/min. : When a product other than the 10 L/min type and 100 L/min are used, [---] is displayed and this Function Setting is not available. : This function cannot be used when CFM has been selected by the unit selection function, [---] is displayed.

Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: S2 (100W Output, Incremental Encoder), Lead: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 100mm

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 25, Motor Type: 100W Output, Incremental Encoder, Lead: LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm, Stroke: 100mm, Motor Option: -, Vacuum Port: -, Actuator Cable Type: -, Actuator Cable Length: -, Driver Type: -, I/O Connector: -

Available response time settings 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

Specification for Option T 11 1 Safety instructions . 11 1 11 2 Specifications . 11 1 11 3 Remote operation . 11 1 11 4 How to connect the power supply and signal cable . 11 2 11 5 How to re-start the operation . 11 2 11 6 Electric circuit . 11 3 Chapter 12 Specification for Option V 12 1 Safety instructions . 12 1 12 2 Specifications . 12 2 12 3 How to perform maintenance . 12 3 12 4 Electric

Option T . 11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 OPERATION / ERROR SIGNAL OUTPUT . 11-1 11.3 REMOTE OPERATION . 11-2 11.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 11-3 11.5 ELECTRIC CIRCUIT . 11-4 Chapter 12 Option V . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 SPECIFICATIONS . 12-1 12.3 MAINTENANCE . 12-2 Chapter 13 Inspection record . 13-1 13.1 INSPECTION RECORD .

If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12. Minimum. setting unit O Operating hamidity range The ambient hamidity range within which the product will meet all published specifications.

proportional valve (VEP type) Current 5 (R1) 4 (A) 1(P) 2 (B) 3 (R2) IRV Simplifying circuit design Space-saving and piping work eliminated 2 (A) 1 (P) Selection of inlet pressure or atmosphere 3 (R) 5 (R1) 4 (A) VEX1 1(P) 2 (B) 3 (R2) SRH SRP SRF System Diagram ARX20 Power amplifier VEA25 VCHR Control circuit Voltage Current ITV 0 to 5 VDC 4 (A) IC 2 (B) PVQ Electro-pneumatic proportional

A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Mass calculation m1 = a x b x c x Relative density Z1 Inertial moment around Z1 axis Z1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) A Inertial moment around Z axis A = Z1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm) Mass

A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)

MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23

MHCM2-7S D8.3 205.2 2-M2 x 0.4 thread (Mounting thread) 2-M2 x 0.4 depth 4 (Mounting thread) 2.5 2 1.5 When open 20 When closed 7 10 6 4.5 15 11 7.7 1.8 16.5 6 100.05 (23) M3 x 0.5 (Finger closing port) 2-M2 x 0.4 thread (Attachment mounting thread) 4 0 0.03 3 12-8-23

11 E 55 75 F 41 52 G 63 68 H 20 20 J Max. 5 Max. 5 K L XLDQ-40 XLDQ-50 65 70 143 153 474 XLAQ/XLDQ Series Glossary of Terms 2 Shaft Sealing Method 1 Seal Materials Bellows Bellows offer cleaner sealing with reduced particle generation and less outgassing.

Doc.IZ*-OMU0031 / Series IZE11 2 7 8 10 10 11 14 15 18 18 F0 19 F1 OUT1 20 F2 OUT2 22 F3 22 F4 23 F5 24 F6 25 F98 26 F99 27 28 31 32 32 34 -1No.IZ*-OMU0031 1) (ISO/IEC)(JIS) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment

No.SFOD-OMO0004-B PRODUCT NAME Electrostatic Sensor Monitor MODEL/ Series IZE11 Table of Contents Safety Instructions 2 Model Identification and How to Order 7 Summary of Product parts 8 Mounting and Installation 10 Installation 10 Wiring 11 Setting 14 Measurement mode 15 Function selection mode 18 Default setting 18 F0 Select connect sensor 19 F1 Operation of OUT1 20 F2 Operation of OUT2

IN of filtered fluid (Port size: R1 or R2) Access to In pressure (Port size: Rp1/4) Access to Out pressure (Port size: Rp1/4) DRAIN Port to discharge accumulated fluid and drain at inlet when replacing the element. (Port size: R3/4) OUT of filtered fluid (Port size: R1 or R2) DRAIN Port to discharge all fluid when replacing the element. (Port size: R3/4) Table 1.

5 Port Air Operated Valve Series VFA3000 How to Order Thread type (Including pilot port) Nil Rc G NPT NPTF Port size (P, A, B port) F N T 01 02 1 8 1 4 R1, R2 port are 1/8. Option F Foot bracket Mounting bracket are supplied, but unattached.