(Refer to page1804 in Best Pneumatics No.3 for the soft resin mold surface.) 15 Magnetic Field Resistant Reed Auto Switch (D-P79WSE type, D-P74 type ) Safety Distance 16 3. Maintenance 3-1.
D 16 inputs M12 connector (5 pins) 8 pcs. E 16 inputs D-sub connector (25 pins) F 16 inputs Spring type terminal block (32 pins) For specications, refer to the Fieldbus system EX600 series in the Web Catalog.
265 255 241 14 284 274 260 15 303 293 279 16 322 312 298 17 341 331 317 18 360 350 336 19 379 369 355 20 398 388 374 6 3 Port Direct Operated Poppet Series VKF300 Base Mounted Type Common SUP, Common EXH/Side Ported Type 42 Manifold Grommet: G DIN terminal: D Manual override (non-locking) Applicable cord O.D. 4 to 6.5 4Rc(PT) 1/8 (ports P, R) 83 71.5 Max .10 2-4.5 (mounting holes) 75.5
M6x1 11 54 6.5 M6x1 12 84 32 15 M8x1.25 14 64 8.5 M8x1.25 12 102 41.5 19 M10x1.5 R S T U V W X Y Z 22 63.5 23.5 22 41 16 9 30 34.5 26 77.5 32.5 27 56 19 10 37 42 37.5 95 50.5 35 68 23 23 45 51 I J K L M N O P Q 76.5 40 46 28 11 14.5 28 15 16 91 46.5 58 32 15 16 30.5 16 21.5 110 55 68 36 16.5 22 37.5 17.5 24.5 A B C D E F G H ML2B25 110 220 206 42 138 93.5 16 73 ML2B32 140 280 264 51 168
Refer to the applicable tubing table to the left LQ LVN Variations Basic size With reducer LVD10 LVD20 Model LVD30 LVD40 LVD50 TI/ TIL Orifice diameter 2 4 8 10 16 Tubing O.D. Metric PA 4 4, 6 6, 8, 10 10, 12 12, 19 Inch Valve type Symbol Type 3, 1/8 1/8, 3/16, 1/4 1/4, 3/8 3/8, 1/2 1/2, 3/4 PAX Basic type N.C. PB PB PA PA N.O. PB B A B A B A N.C. N.O.
Operation Display Panel Page 16 List of Function Page 16 Alarm Page 17 Communication Function Options Page 18 With Caster Adjuster-Foot Page 18 With Earth Leakage Breaker Page 18 With Fluid Fill Port Optional Accessories Page 19 q Piping Conversion Fitting Page 19 w Caster Adjuster-foot Kit Page 20 e Electric Conductivity Control Set Page 20 r Bypass Piping Set Page 21 t Relief Valve Set
Facility water temperature 32C 18 Facility water temperature 32C 16 16 Cooling capacity [kW] Cooling capacity [kW] 14 14 12 12 10 10 8 8 Facility water temperature 40C 6 Facility water temperature 40C 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] 104 Thermo-chiller Standard Type HRS100/150 Series Pump Capacity HRS100
Stainless Steel (mm) A B C D E F G H J L Bracket part no.
For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
Recommended tightening torque Auto switch model Recommended tightening torque [Nm] D-M9 0.05 to 0.15 D-M9A (Water resistant) 0.05 to 0.10 Fig. 8 D-F8 0.10 to 0.20 Set screw Auto switch 29 - Auto switch proper mounting position at rotation end Table 11 Auto Switch Rotation range / Actuation / most sensitive position A A A A B B B B D-M9 D-F8 Magnet Operation range at optimum set position (
Magnet (option) External seal (maintenance part) Heater (option) Pilot port (Pressurized / Totally closed) Axial seal (material : FKM) Scraper (Material : FKM) Valve (material : SUS304) Valve seal (maintenance part) Body(material: A6063) C D C E E (KF Flange) Fn J H B G A Unit: mm A Model A B C D E Fn G H J XLG-16 40 110 38 1 30 17 40 26 XLG-25 50 120 48 1 12 40 26 39 27.5 XLG-40 65 171
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 Revision history G: Revise Safety Instructions.
Symbol Symbol Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 12 x 10 10 x 8 12 x 10 10 x 8 8 x 6 6 x 4 3 x 2 12 x 10 19 x 16 12 x 10 19 x 16 12 x 10 10 x 8 6 x 4 19 x 16 19 x 16 25 x 22 19 x 16 25 x 22 19 x 16 12 x 10 25 x 22 Applicable tubing size (inch) 1/8" x 0.086" 1/4" x 5/32" 3/16" x 1/8" 1/8
) Common wiring (Plug-in) (For manifold) 1/4" One-touch fitting 07 Inch size V C1 Note 17) 5/16" One-touch fitting 09 Note 18) Supply port (PV) size of single unit: 6 (mm), 1/4" (inch) L Note 13) Note 16) Note 12) Solenoid valve with light/surge voltage suppressor Note 13) Standard lead wire length for solenoid valve is 300 mm.
ZZ + Stroke Model B C D E(h8) I K L NA Q x R S TC x R W X ZZ REA50 REA63 0 86 32 53 30-0.033 32-0.039 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 100 38 66 72.2 26 122 69 0 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting nuts/2pcs. packaged with each cylinder d C H d B C Part No.
T 48mm T 48mm C9 JXC9 (EtherNet/IP direct input type) Controller mounting Motor option Nil Screw mounting D DIN rail mounting Nil Screw mounting D DIN rail mounting Select the LECP2 when setting the stroke range using the adjustment unit or an external stop. Nil Without B With lock Nil Without B With lock DIN rail is not included. Order it separately.
C 2 x M depth ML 11.6 P depth PL Air supply port 4 x M depth ML 4 x M depth ML 16.5 16.5 16.5 D D D XT661-10A-(R, L) XT661-8A-(R, L) P depth PL Air supply port P depth PL Air supply port 45 45 45 45 P.C.D. C P.C.D. C 4 x M depth ML 4 x M depth ML 16.5 16.5 D D ZP3 (mm) ZP3E Part no.
Supplementary operation instruction mode 16 7.1 Operation when MODE is ON (Jog operation, teaching) 16 (1) Jog operation 16 (2) Teaching 17 8. Wiring of cables / Common precautions 18 9.
(For band mounting, only the auto switch mounting brackets are assembled before shipment.) * When mounting a band on bore size 8, 10, or 12, the D-A9l(V) cannot be mounted. * When mounting a rail on bore size 8, 10, or 12, the D-A9l(V) and A79W cannot be mounted. * When mounting a rail on bore size 20 or 25, the D-M9l(V), M9lW(V), and M9lA(V) cannot be mounted. 2 C85 Series Specications Bore
D-SMC, P-63 (M) 2nd printing September 1996. D-SMC, P-59(YG) March 1997. 29(YG) Printed in Japan.