Please contact us for the latest version.sales@ocaire.com, FINE LOCK UNIT, ACTUATOR, CLG1 FINE LOCK CYL W/GUIDE, L2, 32MM CLG1 ACCESSORY, 3.32809 lb
Please contact us for the latest version.sales@ocaire.com, TANK FOR HRZ002-L2-N, OTHERS, HRZ- THERMO CHILLER, 21, HRZ NO SIZE RATING, 5.97064 lb
Please contact us for the latest version.sales@ocaire.com, FINE LOCK UNIT, ACTUATOR, CLG1 FINE LOCK CYL W/GUIDE, L2, 32MM CLG1 ACCESSORY, 3.32809 lb
Please contact us for the latest version.sales@ocaire.com, COMPRESSOR KIT FOR HRZ008-L2, OTHERS, HRZ- THERMO CHILLER, 21, HRZ NO SIZE RATING, .00000 lb
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: N (None), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket: None, Calibration
L3 Applicable tubing O.D. d D1 M1 L6 D2 L1 D4 L4 H (Hexagon width across flats) D3 D4 A1 L5 A2 L6 T Inch Size A1 A2 Weight (g) 17 d 1/8" Model H T D1 8.4 D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 ASD230F-U10/32-01D ASD230F-U10/32-03D ASD230F-U10/32-05D ASD230F-U10/32-07D ASD330F-N01-05SD ASD330F-N01-07SD ASD330F-N01-09SD ASD430F-N02-07SD ASD430F-N02-09SD ASD430F-N02-11SD ASD530F-N02-07SD ASD530F-N02
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)