SMC Corporation of America
Elite Part Number Search
Search Results "GP46-10-02ML2-C-X201"

Body Size: 50, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 10 (1), Option: BC (B + C), Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Standard

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)

Series CG1-Z precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Various mounting bracket options are available. Female piston rod threads are available as a standard option. Auto switch capable. Double acting single rod ; Bore sizes

Series CG1-Z precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Various mounting bracket options are available. Female piston rod threads are available as a standard option. Auto switch capable. Double acting double rod ; Bore sizes

Clean SMC's room versions of series CA2.  Available om both relief port and vacuum port type.  The CA2 can be ordered with rod end or rear pivot brackets.  The CA2 is available in a large variety of options that will make them suitable for many different applications.  A variety of auto switches are available for mounting, including compact switches and magnetic field resistant switches.  

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.

The series is available in bore sizes 6, 10, 16mm and stroke lengths from 15 to 200mm.  Mounting options include basic, foot, and front flange. Series CJ2 is auto switch capable.Double acting, double rod for use in clean environment ; Relief or vacuum suction types ; Bore size (mm): 10, 16 ; Auto switch capable

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted.

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

Clean SMC's room versions of series CA2.  Available om both relief port and vacuum port type.  The CA2 can be ordered with rod end or rear pivot brackets.  The CA2 is available in a large variety of options that will make them suitable for many different applications.  A variety of auto switches are available for mounting, including compact switches and magnetic field resistant switches.  

Series CG1-Z precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Various mounting bracket options are available. Female piston rod threads are available as a standard option. Auto switch capable. Double acting single rod ; Bore sizes

Series CG1-Z precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Various mounting bracket options are available. Female piston rod threads are available as a standard option. Auto switch capable. Double acting double rod ; Bore sizes

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted. The CG1 clean series is auto switch capable.

Series 10/11-C(D)G1, available for clean environment, prevent particle generation in a clean room. Series 21/22-C(D)G1 offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted. The CG1 clean series is auto switch capable.

Series 10/11-C(D)A2, available for clean environment, prevent particle generation in a clean room. 21/22-C(D)A2 series offers the same structure as the clean series, and are for the environment in which the use of copper, fluorine and silicon are restricted. The CDA2 clean series is auto switch capable.

Please contact us for the latest version.sales@ocaire.com, VALVE, CONNECTOR,C/ROOM (DC), VALVE, VQ100 SOL VALVE 3-PORT, 15, VQ100 OTHER SIZE RATING, .19204 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, CONNECTOR,C/ROOM (DC), VALVE, VQ100 SOL VALVE 3-PORT, 15, VQ100 OTHER SIZE RATING, .08659 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, CONNECTOR,C/ROOM (DC), VALVE, VQ100 SOL VALVE 3-PORT, 15, VQ100 OTHER SIZE RATING, .08203 lb

Please contact us for the latest version.sales@ocaire.com, VALVE, CONNECTOR,C/ROOM (DC), VALVE, VQ100 SOL VALVE 3-PORT, 15, VQ100 OTHER SIZE RATING, .16570 lb

Please contact us for the latest version.sales@ocaire.com, VALVE,COMPACT,LATCHING,C/ROOM, VALVE, VQ100 SOL VALVE 3-PORT, 15, VQ100 OTHER SIZE RATING, .11023 lb