11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32 40 50 63 2.7-6
Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76 0.41 0.41 0.76 0.41 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19 0.15 0.47 0.39 0.39
I Accessories .10 How To Order ffi-ffi I L_ 1D ft tead wire Switch 9rffix _ -With two switches S-With one switch x Action (Double acting) x%" Stroke: S type only Type 90-D-90(1.5 ft. lead wire) 90AD-90A 97-D-97 93A-D-93A Without switch (built in magnet) End Thread With thread B Without thread B _Nose *D _Clevis mount F -Flange Mount L -Foot mount *T rTrunnion mount 'Auto switch capability
Flow Rate Characteristics Weight (g) Flow rate characteristics 12 (PA) 23 (AR) Model Weight VFN212N-5D-02F 240 VFN212N-5D-02F-D 380 C b Cv C b Cv 2-position Single solenoid 2.68 0.40 0.72 5.41 0.31 1.38 Double solenoid 2.68 0.40 0.72 5.41 0.31 1.38 189 A VFN200N Series Dimensions DIN terminal VFN212N-l D (Y)ll-02l-l 138 19 23 Applicable heavy-duty cord O.D. 6 to 8 Pg 9 Indicator light (With
Metric size ZFC7 ZFC5 Symbol Applicable tubing O.D. 4 6 8 10 12 3 4 5 6 7 Option Nil B None With bracket Inch size B D E F 5/32" 1/4" 5/16" 3/8" Max.
8 F 24 VDC 5 G DIN terminal 24 VDC With surge voltage suppressor A B D E H J L M 4 H 100 VAC Size 2 2 1/4 N.C. 7 J 110 VAC Aluminum 4 5 N.O. 3/8 K 200 VAC 7 L 230 VAC 4 8 7 Resin (With bracket) M Conduit terminal 24 VDC With surge voltage suppressor 4 N 100 VAC 10 7 P 110 VAC A B C D E F G H J K L M N 5 Q 200 VAC Size 3 3 N.C. 8 1/4 R 230 VAC 10 (N.C. only) 6 N.O.
Flow Rate Characteristics Weight (g) Flow rate characteristics 12 (PA) 23 (AR) Model Weight VFN212N-5D-02F 240 VFN212N-5D-02F-D 380 C b Cv C b Cv 2-position Single solenoid 2.68 0.40 0.72 5.41 0.31 1.38 Double solenoid 2.68 0.40 0.72 5.41 0.31 1.38 189 A
VEA 5 (R1) 4 (A) 1 (P) 2 (B) VY2 OFF state VBA VBAT F1 < F2 condition: See figure q. 2 (B) 3 (R2) AP100 4 (A) ON state Immediately after turning on F1 > F2: See figure e. Thereafter F1 = F2: See figure w. 4 (A) 1 (P) 2 (B) 3 (R2) Inw, port 3(R) is half open. 705
oC (3) VQZ 1 8 0.55 16 16 13 11 15 16 25 mm2 VQD P A P B A EA B EB VFS Air exhaust side eff area S (P2=0.5MPa) 18 mm2 VS Note 1) Maximum operating pressure of solenoid valve is 0.9 MPa.
A IDFC60-23-TIDFC70-23-T IDFC80-23-TIDFC90-23-T M3.5 8.5mm M4.0 9.5mm [3.2.5 ] IDFC60/70/80/90 Series 11-3 IDX-OM-W095 T 11.5 IDFC60/70-23-T A B AC 230V50Hz CM OLR FM MC MC2 PRS ILS THR C01 C11 TB CN TDR GFCI EDV PE BK WH IDFC80/90-20-T GR SY A B AC 230V50Hz BU BR YE OR G/Y / IDFC60/70/80/90 Series 11-4 IDX-OM-W095 V 12 V V 12.1 0 () 12.2 ( 10m) (12mm)
N Body 2Yq 3-3/s s-Y4 6 1 A 1 y 2 9-2 B Brackel D Threaded draln poft (Female) except 220. Port slzo o2% o3-% 04-'/z 06 % to1 741'/z 20-2 Thread 1 Male 2fumale. ,NAMC220, 32O,520 only HowTo Select Flow Characteristics Supply prossure: 71 PSI Supply pressurei 71 tl 12 10.5 I 6 ! e E , q 1.5 8 1 2 1 6 2 0 Cylinder speed (in/sec.)
PBT ADC Material Note i Description Material q Description Valve seat (B) Valve seat (A) Pilot body Body Metallic plated ZDC only for external pilot Black zinc chromated o !0 w e Valve assembly Valve spring Return spring Spool spring Head cover Spool valve assembly End cover Piston Plunger NBR ZDC !1 Stainless steel r t ZDC Metallic plated !2 Stainless steel !
IO-Link communication and power supply connector layout (Port Class B) BUS IN: M12 5-pin plug, A-coded No.
Panel mounting Insert panel mount adapter B (supplied as an accessory) into section A of panel mount adapter. Push panel mount adapter B from behind until the display is fixed onto the panel. The pin of bracket engages the notched part of panel adapter section C to fix the display. The switch can be mounted on a panel with a thickness of 1 to 3.2 mm.
Draw a line parallel to the X axis from intersection A and find the intersection (B) between this line and the curve representing 100% relative humidity. 5. Draw a vertical line to the X axis from intersection B. The temperature at the intersection between this line and the X axis is the dew point (in this example, 13oC).
Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W : 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.
Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W: 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.
Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE14 48 39 4.6
The external temperature sensor needs to be prepared separately by the customer. 11 Temperature Alarm b contact 5 Do not use in an explosive atmosphere. Do not mount the product in a location where it can be exposed to (CLOSE During Alarm) RTD wiring 12-14 Unused prolonged sunlight.
If a single-solenoid valve is mounted on the standard wiring manifold, the output number for the B side valve is skipped. : Custom wiring for mixed mounting single-solenoid valves and double-solenoid-valves can be specified with a Wiring Specification Sheet.