4-14 3 Series VNB Process Valve: 2 Port Valve For Flow Control Model Flow characteristics Measured by air Measured by water Weight (kg) Orifice size (mm) Model Port size Rc Air operated External pilot solenoid b C [dm3/ (bar.sec) ] Av x 10-6 m2 Cv VNB1-6A VNB1-8A VNB1-10A VNB24-10A VNB2-10A VNB24-15A VNB2-15A VNB34-20A VNB3-20A 1 8 1 4 0.29 0.17 0.18 0.40 0.32 0.40 0.24 0.42 0.13 25 29 31
P3.5-47 P3.5-53 P3.5-31 P3.5-25 7 (0.38) 3 Balanced Poppet 10.8 (0.6) 5 Rubber Spool 9.9 (0.55) 5 Metal Spool 18 (1) 5 18 (1) 5 6 (0.33) 3 Rubber Spool Metal Spool Balanced Poppet Dual pressure available only on external pilot. 3.5-2 Series VM Related Products No.of Ports Effective Area (mm2) (Cv) Function VR1210 Shuttle Valve 7 (0.38) 3 Dimensions (mm) VR1210: 17.2 X 38 X 29 VR1220: 21.2
With cap SR 6.8 8.7 12 18 25 B 6.5 9 12.5 16 21 A MM h M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 B 4 4 6 6 6 C 12 14 19 27 36 MM B M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 C h1 h2 d f RBC08C RBC10C RBC14C RBC20C RBC27C RB08J RB10J RB14J RB20J RB27J RB08S RB10S RB14S RB20S RB27S 6 7.5 10 20 25 12 14 19 27 36 13.9 16.2 21.9 31.2 41.6 6.5 8 11 16 22 23 23 31 40 51 9 11 15 23 32
supply 2: 20 mA or less Power supply Outputs 0 to 3: External power supply 1 (PWR1) Outputs 4 to 7: External power supply 2 (PWR2) Outputs 8 to 11: External power supply 1 (PWR1) Outputs 16 to 19: External power supply 1 (PWR1) Outputs 24 to 27: External power supply 1 (PWR1) Outputs 12 to 15: External power supply 2 (PWR2) Outputs 20 to 23: External power supply 2 (PWR2) Outputs 28 to 31
. *4) The output turns on when the electric actuator is In position of the step data. 31 - The following table shows the relation of the positon number and the combination of IN0-IN5 or OUT0-OUT5. 0 OFF 1 ON 0 OFF 1 ON No IN5 IN4 IN3 IN2 IN1 IN0 Step Step OUT OUT OUT OUT OUT OUT No 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 1 0 0 0 0 0 1 2 0 0 0 0 1 0 2 0 0 0 0 1 0 3 0 0 0 0 1
Size: 31 (3/8), Model Combination: B (AF+AR), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41)
Size: 31 (3/8), Model Combination: AF+AR+AL, Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: w/o Valve, Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41), Handle Orientation: A (Upward Handle)
Size: 31 (3/8), Model Combination: A (AW+AL), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: w/o Valve, Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41)
Size: 31 (3/8), Model Combination: AF+AR+AL, Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: w/o Valve, Option: 8R (Metal Bowl w/Sight Glass, Flow Direction: Right to Left, Size 31 & 41)
Size: 31 (3/8), Model Combination: B (AF+AR), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: w/o Valve, Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41)
Size: 31 (3/8), Model Combination: AF+AR+AL, Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41), Handle Orientation: A (Upward Handle)
Size: 31 (3/8), Model Combination: B (AF+AR), Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41), Handle Orientation: A (Upward Handle)
Size: 31 (3/8), Model Combination: AF+AR+AL, Port Size: 03 (3/8, Size 31), Accessory: None, All Sizes, Pressure Relief Valve: V (Downstream Valve), Option: 8 (Metal Bowl w/Sight Glass, Size 31 & 41)
LINE Check .20 5.2.5 Help Function .20 5.3 Parameter setting (Driver side) . 21 5.3.1 Change of parameter block .22 5.3.2 Read of parameters .22 5.3.3 Parameter setting method .23 5.3.4 The recommended parameters for each actuator .24 5.3.5 Absolute position detection system .28 5.3.6 Electronic gear .29 5.3.7 Control mode selection .30 5.3.8 Set the parameter of command pulse input form .31
Refer to section 7.5 Parallel I/O signal cable (P.31) for correspondence of terminal numbers and I/O signals. B1 A1 Item Part No.
parts 10 Definition and terminology 11 Electrical Connection 14 Wiring 14 Internal circuit and wiring example 15 Easy Setting 16 Measurement mode 16 Function Setting 19 Function selection mode 19 Default setting 19 F0 Unit selection function 21 F1 OUT1 22 F2 OUT2 24 F3 Response time 26 F4 Auto-preset 27 F6 Fine adjustment of display value 29 F11 Display resolution 30 F80 Power saving mode 31
ZQ-OM01601 // ZQ-ZSV 2 9 10 11 14 14 15 16 16 19 19 19 F0 21 F1 OUT1 22 F2 OUT2 24 F3 26 F4 27 F6 29 F11 30 F80 31 F81 32 F90 33 F96 35 F98 36 F99 38 39 42 43 44 50 51 51 1 - *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
No.PS-OMU0002CN-D // ZSE20A(F) ISE20A 2 8 10 11 15 15 17 19 [] 22 23 3 24 26 28 28 28 F0 30 F1 OUT1 31 F2 OUT2 34 F3 36 F4 37 F5 FUNC 39 F6 41 F10 42 F11 48 F80 49 F81 50 F82 52 F90 53 F96 55 F97 56 F98 58 F99 60 61 65 65 66 75 75 78 -1No.PS-OMU0002CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
Default setting X576 Pa X577 X578 X579 X580 kPa [F 1] Setting of OUT1 Page 31 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected. Hysteresis mode Reversed output Selects which type of switch output is used, normal or reversed.
No.PS-OMU0005CN-C // ZSE20B(F) ISE20B 2 8 10 11 15 15 17 20 [] 23 24 3 25 27 29 29 29 F0 31 F1 OUT1 32 F1 OUT2 35 F3 37 F4 38 F5 FUNC 40 F6 42 F10 43 F11 49 F80 50 F81 51 F82 53 F90 54 F96 56 F97 57 F98 59 F99 61 62 66 66 67 76 76 79 -1No.PS-OMU0005CN-C (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO