SMC Corporation of America
Elite Part Number Search
Search Results "CH2FTC40B-200-A"

Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

These LECS drivers for AC servo motors use pulse input for standalone operation by a PLC.  The LECSA drives motors with 17-bit incremental encoders, while the LECSB drives motors with 18-bit absolute encoders.  The LECSB-T drives motors with a 22-bit absolute encoder. 

Direct input can be given over the network, at up to a 10 Mbps transmission speed.  A positioning table with 255 data points is also available.

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the "easy mode".Body size: 25, 32, 40 ; Ball screw drive  ; Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 ; High output motor (100/200/400W); Pulse input type

The LECSA is a pulse input, positioning type for an incremental encoder, and the LECSB is a pulse input type for an absolute encoder. 

The HRW is rated for high performance temperature stability of ±0.3°C through a set range of 20 to 90°C. The operation panel includes an input keypad and multi-line LCD display. 23 alarms report on a variety of circuit and equipment conditions to facilitate optimal operation.

The HECR is a refrigerant-free temperature control device mountable in a 19-inch rack. Rack mounting recovers desktop or floor space, permitting stacking of related devices and mobility, depending on the rack style. Air cooling frees the installation from dependence on facility cooling water.

Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

LVM20/200 is a compact direct operated 2/3 port solenoid valve for chemicals. LVM's unique internal chamber design reduces the swept volume to a minimum and can mean zero dead volume and carry over.  Operating pressure ranges from -75 kPa to 0.30 MPa. LVM20/200 is available as body ported, direct tube connection or base mounted.

Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz); 200~230; STO (Safe Torque Off) safety function available; Display and settings buttons for direct input and status monitoring; Compliant with SEMI F47 Standard; SigmaWin+ Configuration software required (download available separately)

These LECS drivers for AC servo motors use pulse input for standalone operation by a PLC.  The LECSA drives motors with 17-bit incremental encoders, while the LECSB drives motors with 18-bit absolute encoders.  The LECSB-T drives motors with a 22-bit absolute encoder. 

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5

1 Speed Controller: Standard Type Series AS Large Flow In-line Type Model Able to control and set a constant speed easily. Speed may be accurately controlled even at low speed. Retainer prevents accidental loss of needle.

Dimensions Option B (Without auto drain) Option/Dimensions Model Metal bowl Metal bow with level gauge Without drain cock Drain cock thread piping With drain guide AF800 AF900 409 489 440.5 520.5 393.5 473.5 410 490 406.5 486.5 B (With auto drain) A B C D N.O N.C E Model AF800 AF900 150 200 410 490 33 46 140 170 439 519 472 552 200 260 Precautions Be sure to read before handling.

(l/min (ANR)) Flow (l/min (ANR)) Effective area (mm2) Effective area (mm2) Flow (l/min (ANR)) 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Needle rotation (Turns) Needle rotation (Turns) Needle rotation (Turns) ASD530F ASD630F 1000 1500 14 20 10, 11 12 Flow (l/min (ANR)) Effective area (mm2) Effective area (mm2) Flow (l/min (ANR)) 12 1000 10 8 10, 11, 12 08, 09 15 500

) 2, 3, 4, 5, 6, 8, 10 2, 3, 4, 5, 6, 8, 10 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 1-1/4" 32 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a