Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 1,500 / 1,700, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 2000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 55, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 3/4, Control Side Connection
Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 2,600 / 2,800, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 5000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 55, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1, Control Side Connection
Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 2,600 / 2,800, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 5000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 55, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1, Control Side Connection
Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto s, Cylinder, Air, ROUND BODY CYLINDER, 439, 0.468 lb
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
V PLC Terminal conduit 2-wire 24 V 12 V Yes Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.
No gauge port No pressure gauge No code 0 V3 L 1 H 2 4 Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.
V 2-wire PLC 12 V No 200 V or less 24V Terminal conduit Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indicator) *1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Cylinder stroke (mm) Auto switch MK2T 40 50 63 50, 75, 100, 125, 150 50, 75, 100, 125, 150, 200 50, 75, 100, 125, 150, 200 Nil Without auto switch (built-in magnet) Without switch mounting rod Without auto switch (built-in magnet) With switch mounting rod CK1 CK1 P Built-in Standard (Strong) Magnet Cylinder Part No. CLK2 Select applicable auto switch models from the table below.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Also, when exceeding the air cushion stroke ranges on page 960, the piston speed should be 100 to 200 mm per second. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range.
W 400 W 100 W 200 W 400 W Type AC servo motor (S2) AC servo motor (S3) AC servo motor (S4) AC servo motor (S6) AC servo motor (S7) AC servo motor (S8) Symbol C S1 S3 S41 SSCNET III type (For absolute encoder) Incremental S S5 S7 S81 Power supply voltage Absolute 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz 1 Not applicable for Series LEY Dimensions LECSAm 40 135 2 x 6 Mounting hole
A 10 B 15 C 20 Produced upon receipt of order (Robotic cable only) Refer to the specications Note 2) on pages 9 and 10.
320 2775 70 150 220 2905 30 MHF 120 198 318 3820 32 20 MHL 160 242 402 4655 100 188 288 5270 30 JIS Symbol MHR 160 246 406 6830 40 20 200 286 486 7905 MHK Note) The open and close time spans represent the value when the exterior of the workpiece is being held.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire
Stroke adjustment range: 0 to 10mm (8) : 0 to 25mm (12 to 40) Series variations Options Standard stroke (mm) End lock Cushion Rod end configuration Model Rod through hole Variable stroke Extension adjustment 5 10 50 30 25 20 15 75 100 125 150 175 200 New New MTS8 Rubber bumper MTS12 Female threads (standard) MTS16 MTS20 Air cushion Male threads (optional) MTS25 MTS32 MTS40 Features 2 Series
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .