for mounting attachment) 46 58 45 45 42 26H9 + 0.052 depth1.5 0 30 Positioning pin hole 60 18 5 86 30 107 Auto Switch Mounting Groove Dimensions M5 x 0.8 (Finger opening port) 14 24 M5 x 0.8 (Finger closing port) 42 8 3 4 3 MHY2-25D2 Opening/Closing direction through-hole type 4 x 5.5 through (Hole for mounting attachment) 12 -0.005 -0.025 6 12 22.5 (Limted area for mounting attachment) Do
Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14
Do not place a magnetic object near the pressure switch. Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.
N Nil Rc 3 1 0 14 to 60 l/min 20 to 1500 l/min 36 to 2600 l/min NPT Specifications Water/Non corrosive liquid Copper alloy Fluid Stainless steel 304 Liquid, which do not corrode stainless steel 304. Max. pressure 1 MPa 1.75 MPa Water resistance Insulation resistance 100 M (500 DC by megameter) 1500 VAC for one min.
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.
Do not use any other agent except a seal tape. q Contact SMC if using fluids other than air. w Do not supply air pressure from 2(A) port. The air will leak to 1(P) port. e Since the valve may have slight air leakage, it may not be suitable for holding pressure in a pressure vessel.
Chromated C3604B Piston C3604B Spring holder Zinc chromate SWP Parallel pin Zinc chromate SWPB Spring SUS304W Valve spring PVC Packing w Do not remove the retaining screw of the handle. If the screw falls off, it could lead to a malfunction.
Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.
Do not attempt to rotate, as it does not turn Cable connection threads RC(PT) 1/4 Exhaust porl EXH (3) Port size 4-M5 x 0 8 thread depth 6mm Mounting hole 2-RC(PT) 1/4, 3/8 SUP port, OUT porl rTl|z000/3000 tleflru-Pltotllnalic Re[ula 0imeffiiolt$ ITV3OtrT Cable connector (4 wire) Cable connector (4 wire) . Do not anempt to rotate. as it does not turn.
NCf,IW NCDMW 'Noie: lf ordered do rubber bumper, orcrall length docreases .25 inches. o svE' Stainless Steel Cylinder Air Cylinder Series NCM Specifications 250 PSt(17.5 kgf/cm') 8 PSI (0.5 kgf/cm'?)
Do not use fluid which corrode the wetted parts material. 2. Do not use the products for medical or food applications. 3. The applicability may vary depending on additives. Take note also of additives. 4. The applicability may vary depending on impurities. Take note also of impurities. 5. Examples of transfer liquids are shown in the table on the left.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6 A
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.
D DIN terminal DL DIN terminal with light DO DIN terminal (without connector, with gasket) Orifice diameter and Port Size Combinations T Conduit terminal Class Orifice diameter (mm) Port size 2 4 3 7 5 10 1/8 ( 6A) V V V V 2 1/4 ( 8A) V V V V 1/4 ( 8A) V V V V 3 3/8 (10A) V V V V V 1/2 (15A) V Connector 1/4 ( 8A) V V V V 3/8 (10A) V V V V V All class B coils come with surge
Do not apply a lateral load on the main body during or after mounting. 3. When the silencer has loosened due to vibrations from the mounted equipment, mount the silencer after applying an anti-loosening agent to the thread. 612
Do not use any sealing agent other than seal tape. Design Warning 1. Please contact SMC when fluids other than air are used. 2. Do not supply air pressure from 2(A) port. The air will leak out from 1(P) port. 3. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel.
How to Order Do not replace heavy duty scrapers. XC4 Since heavy duty scrapers are press-fit, do not replace the cover only, but rather the entire rod cover assembly. The CM2 series cannot replace either heavy duty scraper or rod seal. (It goes for replacing retainer assembly for the CS1 series.) Replace the CNA2 series with the lock unit.
Electrical entry 1/4 (AV2000 only) 3/8 (AV3000 only) 1/2 (AV4000 only) 3/4 (AV5000 only) 1 (AV5000 only) 02 03 04 06 10 G: Grommet Coil rated voltage 1 2 3 4 5 6 7 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 240VAC (50/60 Hz) Other D: Type D DIN terminal (With connector) Option Nil G None With pressure gauge How to Order Pilot Valve Assembly DO
Do not cut the tube with cutting pliers, nippers, scissors, etc.) 2. Grasp the tube, then slowly push it until it comes to a stop. 3. Then, pull it back gently to make sure that it does not come out.