Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider (or the piston slider by using air pressure) back to the proper position at the stroke end. (When pushing the external slider, do not push it with bare hands.) 4. Do not apply lubricant, as this is a non-lube product.
Do not scratch the sliding portion of the piston rod or the outside threads of the outer tube. Do not scratch or gouge the sliding portion of the piston rod or the outside threads of the outer tube by striking it with an object, squeezing it, or by forcefully wedging a set screw in it.
Do not adjust strokes by moving the stopper, as this can cause cylinder damage.
Caution SMC Pressure Switch and Pressure Sensor do not have explosion-proof construction; do not use flammable gases or liquids. Also, do not use toxic gases or liquids. 888
Do not use for rotational applications, because it is not a fitting designed for rotational axis. Be sure to read before handling. Refer to pages 10-24-3 to 10-24-6 for Safety Instructions and Actuator Precautions. Maintenance Warning 1. Do not reuse if disassembled.
(ML2B) (CE1-R) DO-ring Parts sorting: To classify the different types of parts.
Do not apply pressure from the head side of a single acting type cylinder. If air is supplied from the head side of a single acting cylinder, blow-by of the air will occur. 4. Do not expose the shock absorber to machining oil, water, or dust. This will cause the shock absorber to become damaged, leading to air leaks. 3. Do not scratch or gouge the sliding portion of a piston.
Failure to do so could cause the snap ring to become detached or the set screws to shift, causing the plates to fall off.
Do not perform unlocking while an external force such as a load or spring force is being applied. This is very dangerous because the cylinder will move suddenly.
Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider (or the piston slider by using air pressure) back to the proper position at the stroke end. (When pushing the external slider, do not push it with bare hands.) 4. Do not apply lubricant, as this is a non-lube product.
EX600-LAB1 Model EX600-LBB1 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Class B IO-Link port type Class A COM1 (4.8 kbps) COM2 (38.4 kbps) COM3 (230.4 kbps) Depending on connected sensor/actuator Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Error Name Error Display Error Type Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Error name Error display Error type Troubleshooting method Turn the power off and remove the cause of the over current. Then turn the power on.
Do not cut the insulator. Insert the corresponding wire colour shown in the table into the pin number printed on the sensor connector, to the bottom.
Function Setting Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Mounting screw Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not allow it to idle for a long time. If the pump is operated for a long time without any fluid inside or in a gas-fluid mixed state, the diaphragm may be damaged or the life may be shortened. Do not continue idling except for priming the pump. 5 11.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
The received message is deleted if the calculation result and received LRC do not match. Consecutive 8 bits of the message are added, and the result without carry (overflow) is converted to 2's complement.