Volume Double vane Single vane Vane type CRB2BW40-S CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D CRB2BW40-D CRB2BW10-S CRB2BW15-S CRB2BW20-S CRB2BW30-S Model Rotation 90 180 270 90 180 270 180 270 180 270 180 270 90 100 90 100 90 100 90 100 90 100 90 90 90 1 (0.6) 1.5 (1.0) 4.8 (3.6) 11.3 (8.5) 25 (18.7) 1.2 1.5 2.9 3.7 6.1 7.9 15 20.2 31.5 41 1.0 1.1 2.6 2.7 5.6 5.7 14.4 14.5 33 34 Volume

A 152.5 154 B 52.5 54 E 52 64 I 69 86 J 5 7 M 40 50 N 5.5 6.6 O counterbore 9 depth 7 11 depth 8 T 44 56 Z 14 19 W 66 80 U 35 41 Bore size (mm) 40 50 Data Note 1) Dimensions without auto switch are the same as drawing above. Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.

5 Brass Spring seat i 6-3-40 41 41 Series CJ2K Air Cylinder: Non-rotating Rod Type Single Acting, Single Rod, Spring Return/Extend Single Acting, Spring Return: Basic Style (B) CJ2KB S Port location on head cover Bore size Stroke Piping port M5 x 0.8 Piping port M5 x 0.8 Mounting nut Rod end nut CJ1 CJP S + Stroke Rod section CJ2 Port location on head cover: Axial location (R) Z + Stroke

about the rod end nut and accessory brackets, refer to page 7-6-20. 7-4-10 11 Series CQS Compact Cylinder: Standard Type Double Acting, Single Rod Foot Style Foot style: CQSL/CDQSL B + Stroke Special cap bolt Standard stroke range (mm) Long stroke range (mm) Without auto switch With auto switch Without/With auto switch Long stroke Standard stroke Bore size (mm) LS B 20 20 29 29 A 32 32 41

Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.

(1) Operation check by test drive . 41 (2) Operation check with the monitor . 41 5.4.1 Operation check by test drive. 41 (1) Operation check by test drive in easy mode . 41 (2) Operation check by test drive in normal mode . 43 5.4.2 Operation check with monitor . 45 (1) Operation check with monitor in easy mode . 45 (2) Operation check with monitor in normal mode . 46 6.

Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth

If screws other than those specified are used, it may cause the switch to be damaged. 3 41 41 38 5 68 68 63 Auto Switch Dimensions Unit: mm Auto switch internal circuits D-M9 Mounting screw M2.5 x 4 Slotted set screw D-M9N D-M9B, N, P Common DC (+) Brown [Red] Indicator light 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black [White] 2.7 2.8 4 22 DC (-) Blue [Black]

D-M9BW(V), D-M9NW(V), D-M9PW(V) Stroke (mm) 20 41 29 41 29 47 35 Stroke (mm) Model Model Normally closed (NC = b contact) solid state auto switches (DF9G/F9H types) and a solid state auto switch (D-F8) are also available.

D-M9N-746 D-M9P-746 D-M9B-746 0.5 8 8 7 Lead wire length m Auto Switch Internal Circuit 3 41 41 38 5 68 68 63 MHZ D-M9N-746 MHF DC(+) Brown Auto Switch Dimensions Main circuit of switch Main circuit of switch Main circuit of switch MHL OUT Black D-M9N-746/D-M9P-746/D-M9B-746 MHR Mounting screwM2.5 x 4l Slotted set screw Indicator light DC(-) Blue MHK D-M9P-746 MHS 2.6 746 DC(+) Brown MHC

41 40 5H9 0 +0.030 M6 x 1 37 6.8 10 17 10 28 21h9 -0.052 0 55 6H9 0 +0.030 19.5-0.1 0 50 47 M8 x 1.25 51 8.6 12 34 22 12.5 1428 Escapements Series MIW/MIS Finger options Tapped on upper and lower faces Tapped on all faces Attachment mounting thread 4 x FD through Attachment mounting thread 2 x FD through FF FE FF FE Attachment mounting thread FD thread depth FG FC FC RSQ FA FF FE FA RSG

C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM B 6 6 6 6 6 C 22 27 32 41 41 Part no. Part no. Part no.

590 AMV 3/4 200 72 74 41 710 1 200 72 74 41 605 AMP 1 200 72 74 41 725 1 230 72 74 41 665 1 230 72 74 41 810 11/4 240 72 74 54 765 11/4 240 72 74 54 910 11/2 240 72 74 54 790 11/2 240 72 74 54 935 609 5.0 MPa 5.0 MPa Applications included air-blowing, charging fluid into a vessel, or discharging (Blow-molding equipment, etc.)

Weight [g] D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.The auto switch may be damaged if a screw other than the one supplied is used. 5 68 68 63 How to Order D-M9 N Auto Switch Internal Circuit D-M9N(V) Series Lead wire length Nil M L Z 0.5

18.5 17 26.5 10 23 40.0 28.4 1 2 KRY10-04S 54.5 66 31 41 22 1 4 3 8 KRY12-02S KRY12-03S 53.5 55 17 57.4 45.4 24 17 28.5 1 2 KRY12-04S 20.9 57.5 68 12 Connection thread (With seal) 22 Reference dimensions after R thread installation.

Return to origin . 41 8.1 Return to origin . 41 8.2 Positioning operation . 41 8.3 Pushing operation. 42 (1) Pushing operation is successfully performed. . 42 (2) Pushing operation is failed (pushing the air) . 42 (3) Movement of the work piece after the completion of the pushing process .. 42 8.4 Controller input signal response time . 43 8.5 Methods of interrupting operation . 43 9.

Piping . 41 5-7. Operating environment . 41 5-8. Lubrication . 41 6. Maintenance or inspection . 41 6-1. Maintenance or inspection . 41 6-2. Replacement part . 42 6-3. Maintenance . 42 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

(mm) Rod end male threads a b c e f g h Bore size (mm) 20 11 15 M10 x 1.25 6 10 23 66 25 14 18 M12 x 1.25 6 12 26 71 32 21 25 M16 x 1.5 7 14 35 86 40 26 30 M20 x 1.5 7 19 40 95 50 31 35 M24 x 1.5 8 24 46 106 63 41 45 M30 x 1.5 9 30 58 125 80 56 60 M39 x 1.5 14 41 77 155 100 71 75 M48 x 1.5 21 50 101 197 7 Series CHKDB Auto Switch Specifications Auto Switches: Proper Mounting Positions and

Rod end male threads (mm) Bore size (mm) a b c e f g h 20 11 15 M10 x 1.25 6 10 23 66 25 14 18 M12 x 1.25 6 12 26 71 32 21 25 M16 x 1.5 7 14 35 91 40 26 30 M20 x 1.5 7 19 40 105 50 31 35 M24 x 1.5 8 24 46 116 63 41 45 M30 x 1.5 9 30 58 135 80 56 60 M39 x 1.5 14 41 77 165 100 71 75 M48 x 1.5 21 50 101 207 19 Series CHKGB Auto Switch Specifications Auto Switches: Proper Mounting Positions

Operating temperature range 41 to 122F (5 to 50C) Operating humidity range [%RH] 90 or less (No condensation) Weight [g] 350 (Except cable) Note) CE-compliance The EMC compliance of the teaching box was tested with the LECP6 series step motor controller (servo/24 VDC) and an applicable actuator.