Part Number Description: ELBOW 1/8NPT TO 10-32 Product Line: V Product Line Description: VALVE Family Code: 364 Family Description: SS5YJ3 MFLD SYJ3000 Class Code: 11 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Part Number Description: FITTING 10-32 BARB Product Line: V Product Line Description: VALVE Family Code: 364 Family Description: SS5YJ3 MFLD SYJ3000 Class Code: 11 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
No.EX-OML0010CN-C / / EX600-HT1A 2 8 8 9 10 10 11 12 12 13 1. I/O monitor(I/O ) 15 2. Diagnosis Data() 24 3. Sys. Configuration() 27 4. Parameter Setting() 33 5.
No.PF-OMH0003-F PRODUCT NAME 4-channel Flow Monitor (Remote type monitor unit) MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 15 Installation 15 Wiring 16 Outline of setting 19 List of outputs 20 Initialize mode 21 Default
Keep the screwdriver away from the auto switch when searching mounting position of the auto switch where it operates correctly. 12 - 2. Keep a gap wider than the values listed in the table when arranging the magnet grippers side by side or when placing the magnet grippers close to magnetic objects such as iron.
When the load is up to 12 W, use both the Power block and a high wattage load Output block. For low Current Output to connected load (output equipment) or manifold valves using the power supply from the SI unit. EX9-OET1 EX9-OET2 wattage load For high Current Output to connected load (output equipment) using an external power supply.
EX250-SAS3/-SAS7: 8 points EX250-SAS5/-SAS9: 4 points -24No.EX-OMP0025-A Fault No.12 Problem Possible cause Investigation method Countermeasures Tighten the screws while holding the SI unit and the input block so that there is no gap between them.
No.EX-OML0011-C PRODUCT NAME Fieldbus Device Handheld Terminal MODEL / Series / Product Number EX600-HT1A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Names and Functions of Product 8 Definition and terminology 9 Mounting and Installation 10 Precautions before mounting 10 Wiring 11 Setting and Adjustment 12 Basic operation 12 Mode selection 13 1.
Follow the items below to prevent the generation of abnormalities in the product. 41 - Doc. no. ZQ-OM00801-D 1. Use voltage within the rated voltage. 2. Do not lubricate the supply air. 3. Do not directly apply liquid such as water on the body. 4. Do not apply a strong impact. 5. Do not mix drain or dust in the supply air. 6.
Piston assembly Valve Valve spring No. 4 5 6 1348104A 1348105 1348109 SUP OUT 2 ARX Series Specialty Regulators Regulator for 290 psi (2 MPa) ARX20, 21 Dimensions Panel cutout dimensions 1.02 (26) R .1 (2.5) SUP OUT SMC K C O P A A L U S H .5 (12) 1.61, 2.13 [41 (K40)], [49 (K50)] 2.13 (54) .98 (25) 1.6 (max. thickness 4.5) 1.73 (44) .21 (5.4) 3.13 (79.5) (when regulating pressure = 3.23
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 Nozzle size Nil 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, MANIFOLD, VACUUM EJECTOR, M02, 41 lb
- (mm) L1 L2 L3 L4 L5 L6 16 5 MHM-16D 1 1 1 1 MHM-25D 36 34 MHM-32D 50 24 MHM-50D 23 25 80 41 / 3 NPN 3 PNP PLC PLC 2 2 PLC PLC PLC PLC -13- AND(),OR() *50ms 3 NPN OR 3 NPN AND 1 1 1 2 2 2 3 PNP AND 3 PNP OR 1 1 1 2 2 2 2 AND 2 OR 2 AND ON , 2 ON 20V 2 OR OFF OFF 1 1 ON 2 2 ON =-2 OFF =2 =1mA2 3k =6V 3k 1mA =24V-4V2 =16V DC24V 4V 2-8.
When any vibration, impact, or load is applied to the manifold, be sure to use the direct mounting manifold. 12 No.JSY1000V-OMW0002-B JSY1000/3000/5000 series Specific Product Precautions 5 Be sure to read this before handling.
1 12 !3 Scraper Rod seal 12 is a non-replaceable part, so it is not included in the seal kit. Set of left nos. o, !0, !1, !3 Piston seal NBR Piston gasket Tube gasket CHQ100-PS Seal kit consists of items o, !0, !1 and !3 and can be ordered by using the seal kit number for each bore size. Special tool required for disassembly. Contact SMC for recommended tool designs and dimensions.
1 12 !3 Scraper Rod seal 12 is a non-replaceable part, so it is not included in the seal kit. Set of left nos. o, !0, !1, !3 Piston seal NBR Piston gasket Tube gasket Seal kit consists of items o, !0, !1 and !3 and can be ordered by using the seal kit number for each bore size. Special tool required for disassembly. Contact SMC for recommended tool designs and dimensions.
The ZB is available as a single unit or mounted to a manifold of up to 12 stations. Manifold for compact ZB ejector/vacuum pump system, Up to 12 stations available as standard, Mountable or non-mountable base for sensor/switch, Manifold, 5 stations, VACUUM EJECTOR, M02, 41 lb
(inch) Connection thread UNF NPT
Page 7 Application Information .. . . . . .. ... . .. ' Drawings Pages 8-10 Page 11 Auto Switch Specifications . .. .. . . . ' Page 12 Auto Switch Mounting/Accessories . . . . ' Pages 1314 Setup Instructions/Cautions . . . , , ... ' Page 15 Unit Conversion Chart . ' . ... . .. . . ,.