Search Results "G46-15-01M-C"

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female), Gauge Port, Inlet

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Range Options: Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female), Gauge Port, Inlet

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female), Gauge Port, Inlet

Delivery Pressure: 15 [5 to 150 psig (0.034 to 1.0 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: MV8 (1/2 Inch Face Seal, Male), Connections, Outlet: MV8 (1/2 Inch Face Seal, Male), Gauge Port, Inlet:

SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.  Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.  Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full

Item event No. code Bit 15 Error ON with any of Bits 11 to 14 of Byte 4 Set, otherwise 0. Bit 14 Memory error 0x1810 Occurs on memory error. Bit 13 System error 0x1811 Occurs when a system error . Bit 12 Solenoid valve error 0x1812 Occurs when a solenoid valve error .

Operating method / operation . 15 5-1. Design . 15 5-2. Installation . 15 5-3. URCap . 19 5-4. Air supply . 24 5-5. Piping . 24 5-6. Operating environment . 24 5-7. Lubrication . 25 6. Maintenance . 25 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Proper tightening torque Nm {kgfcm} Tightening torque for piping Connection threads M5 Rc(PT) 1/8 1.5 to 2 {15 to 20} 7 to 9 {71 to 92} Reference: Tightening into the M5 fitting threads After tightening by hand, tighten about 1/6 of a turn further using a tightening tool.

S, Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% Operating pressure (MPa) Bore size (mm) 0.3 Operating direction 0.5 0.7 181 IN 302 422 32 241 OUT 402 563 Standard Stroke 317 IN 528 739 40 (mm) Bore size (mm) Standard stroke 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 377 OUT 628 880 IN 495 825 1150 32 1 50 OUT 589 982 1370 40 50 2 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15,

Preparation before piping 1/8 30 to 45 3 to 4 Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 3/8 15 to 30 8 to 9 1/2 15 to 30 14 to 15 2) The gasket can be reused up to 6 to 10 times. It can be replaced easily when it has sustained damage.

C: Revision. D: Limited warranty and Disclaimer are added. E: Modified errors in text. F: Revision. G: Contents are added. [July 2016] H: Contents revised in several places. [December 2021] I: Contents are added.

Investigate the cause of the voltage fluctuation, and take countermeasures against it. 15 to 30 VDC Check that the solenoid valve power supply voltage is within the specified range.

Refer to pages 15 through 24 for safety instructions and precautions. Bore size (mm) Standard strokes (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting Caution Mounting and Accessories 1.